Catholic Housing Services JN 16298 <br /> November 1, 2016 Page 6 <br /> we recommend that the piles be assumed to have a point of fixity (point of maximum bending <br /> moment) at a depth of 10 feet below the top of the pile. The lateral capacity of a pile is a function of <br /> both the soil that surrounds the pier and the composition of the pile itself. Passive earth pressures <br /> on the grade beams will also provide some lateral resistance. If structural fill is placed against the <br /> outside of the grade beams, the design passive earth pressure from the fill can be assumed to be <br /> equal to that pressure exerted by an equivalent fluid with a density of 300 pcf. This passive <br /> resistance is an ultimate value that does not include a safety factor. <br /> FOUNDATION AND RETAINING WALLS <br /> Retaining walls backfilled on only one side should be designed to resist the lateral earth pressures <br /> imposed by the soil they retain. The following recommended parameters are for walls that restrain <br /> level backfill: <br /> I'ARAIVI ETER VALUE <br /> Active Earth Pressure* 35 pcf <br /> Passive Earth Pressure 300 pcf <br /> Soil Unit Weight 130 pcf <br /> Where: pcf is Pounds per Cubic Foot, and Active and Passive <br /> Earth Pressures are computed using the Equivalent Fluid <br /> Pressures. <br /> * For a restrained wall that cannot deflect at least 0.002 times its <br /> height,a uniform lateral pressure equal to 10 psf times the height <br /> of the wall should be added to the above active equivalent fluid <br /> pressure. <br /> The design values given above do not include the effects of any hydrostatic pressures behind the <br /> walls and assume that no surcharges, such as those caused by slopes, vehicles, or adjacent <br /> foundations will be exerted on the walls. If these conditions exist, those pressures should be added <br /> to the above lateral soil pressures. Where sloping backfill is desired behind the walls, we will need <br /> to be given the wall dimensions and the slope of the backfill in order to provide the appropriate <br /> design earth pressures. The surcharge due to traffic loads behind a wall can typically be accounted <br /> for by adding a uniform pressure equal to 2 feet multiplied by the above active fluid density. Heavy <br /> construction equipment should not be operated behind retaining and foundation walls within a <br /> distance equal to the height of a wall, unless the walls are designed for the additional lateral <br /> pressures resulting from the equipment. <br /> The values given above are to be used to design only permanent foundation and retaining walls <br /> that are to be backfilled, such as conventional walls constructed of reinforced concrete or masonry. <br /> It is not appropriate to use the above earth pressures and soil unit weight to back-calculate soil <br /> strength parameters for design of other types of retaining walls, such as soldier pile, reinforced <br /> earth, modular or soil nail walls. We can assist with design of these types of walls, if desired. The <br /> values for friction and passive resistance are ultimate values and do not include a safety factor. <br /> Restrained wall soil parameters should be utilized for a distance of 1.5 times the wall height from <br /> corners or bends in the walls. This is intended to reduce the amount of cracking that can occur <br /> where a wall is restrained by a corner. <br /> GEOTECH CONSULTANTS,INC. <br />