Laserfiche WebLink
VERETT <br />0 <br />Permit Number: P2407-049 <br />Applied: 7/31/2024 <br />Issued: 8/1/2024 <br />Status: FINALED <br />Parent Permit: B2403-145 <br />Parent Project: <br />Details <br />Permit Inspections <br />City of Everett <br />Approved:7/31/2024 <br />Finaled: 10/10/2024 <br />Description: REPAIR/REPLACE FIRE DAMAGED PLUMBING <br />Site Address: 9017 9TH AVE SE <br />City, State Zip Code: EVERETT, WA 98208-3314 <br />Applicant: LINH T TRAIN <br />Owner: TRAIN LINH & KHUC HUONG <br />Contractor: OWNER <br />SCHEDULED DATE <br />COMPLETED DATE <br />TYPE <br />INSPECTOR <br />RESULT <br />REMARKS <br />8/5/2024 <br />8/5/2024 <br />PLUMB 03-ROUGH <br />JASON <br />CORRECTION <br />see notes <br />IN <br />MORRISSEY <br />REQUIRED <br />Notes: <br />LIHN (425)737-2836 <br />- Missing nail plates on all DWV stud penetrations. UPC chap 3.- Cap off trap arm for non code wet vent on downstairs AW drain or upsize wet vented <br />pipe to 2" per UPC chap 9.- Replace firnco coupling with solid banded mission coupling or glue coupling per UPC chap 3.- Upsize gas to 3/4" for tankless <br />water heater and put gas system on 15 lb test.- Install hammer arresters on AW valves now or at final per UPC chap 6. <br />8/7/2024 <br />8/7/2024 <br />GAS 01-ROUGH IN <br />JASON <br />APPROVAL <br />see notes <br />MORRISSEY <br />Notes: <br />- Replacement of 1/2" nipple to 3/4" for new tankless gas supply as well as retesting of existing gas supply. <br />8/7/2024 <br />8/7/2024 <br />PLUMB 03-ROUGH <br />JASON <br />APPROVAL <br />see notes <br />IN <br />MORRISSEY <br />Notes: <br />LINH (425)737-2836 <br />- Replacement of all existing water lines with pex, (all ABS DWV to remain as existing). New fiberglass tub shower surround in upstairs main bath with <br />new waste and overflow. *** Water and waste for downstairs stand alone sink can be a bar sink only. No full size kitchen sink allowed unless plans are <br />approved for ADU. <br />9/30/2024 <br />9/30/2024 <br />PLUMB 08-FINAL** <br />JEFF M RHODE <br />CORRECTION <br />see notes <br />REQUIRED <br />Notes: <br />-caulk fixtures-t and p ran to outside -grade in condensate line -atmospheric vent furnace cannot be installed in restroom-finish trim in lower restroom- <br />bar sink not installed down stairs left at rough in -air gap required for dishwasher <br />10/10/2024 <br />10/10/2024 <br />PLUMB 08-FINAL** <br />JEFF M RHODE <br />APPRVD-PERMIT <br />see notes <br />FINAL <br />Notes: <br />LIHN (425)737-2836 <br />-bar sink not to be finished left at rough in (see picture) -washer and dryer not installed at time of inspection <br />I <br />Printed: Friday, 04 April, 2025 1 of 1 rk <br />SUPERION <br />