My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 40-26 2025-10-22
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 40-26
>
3003 W CASINO RD BLDG 40-26 2025-10-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/22/2025 9:27:59 AM
Creation date
4/4/2025 1:29:44 PM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 40-26
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4 <br />TOP 2 ARMS TO BE REMOVED OR <br />MARKED "NOT TO BE LOADED." <br />TYPICAL FOR ALL (4) UPRIGHTS <br />SPECIAL INSPECTIONS REQUIRED <br />FOR STORAGE RACKS PER IBC <br />1705.13.7. <br />PERIODIC SPECIAL INSPECTION <br />SHALL BE REQUIRED FOR THE <br />INSPECTION OF STORAGE RACK <br />ANCHORAGE INSTALLATION. <br />PERIODIC SPECIAL INSPECTION <br />SHALL BE REQUIRED FOR THE <br />COMPLETED STORAGE RACK <br />SYSTEM, TO INDICATE <br />COMPLIANCE WITH THE <br />APPROVED CONSTRUCTION <br />DOCUMENTS. <br />IrfllMom <br />1. RACK TYPE: CANTILEVER <br />2. POSTED LIMIT LOAD: 750 LBS MAXIMUM PER SUPPORTING <br />ARM. LOAD TO BE DISTRIBUTED <br />EVENLY ALONG SUPPORTS. <br />NOTE: EXISTING LOAD RATING IS <br />2000 LBS PER SHELF. A NEW <br />PLAQUE FOR THE UPDATED LOAD <br />RATING WILL NEED TO BE INSTALLED. <br />3. ARM SECTION: 402 <br />4. UPRIGHT SECTION: 942 <br />5. BASE: 714/724 <br />6. ANCHOR BOLTS: (40) q"x3j" HILTI KWIK HUS-EZ W/ <br />3j" NOMINAL EMBEDMENT DEPTH, <br />(10)BOLTS EA. BASE AS SHOWN <br />(5 BOLTS EACH SIDE OF BASE, TYP. <br />FOR ALL 4 BASES) <br />NOTE: ALL NEW ANCHOR BOLTS <br />MUST SPACED 4" MINIMUM <br />FROM EXISTING ANCHOR BOLTS <br />BOLT LINE PLACED ON CENTER OF <br />BASE BEAM <br />PALLET RACK ELEVATION 7. LOCATION: 40-25.4 M-9.5 <br />SCALE: NTS <br />I ? �L BOE/A/O• <br />ELEVATION & NOTES <br />BUILDING 40-25.4 CANTILEVER RACK <br />
The URL can be used to link to this page
Your browser does not support the video tag.