Laserfiche WebLink
Post Capacity for Combination of Flexure and Axial Load <br />Lever arm to C/L of post: <br />2.42 <br />ft <br />elf <br />l <br />DL <br />PL <br />MDL <br />MPL <br />(K) <br />(K) <br />(ft-K) <br />(ft-K) <br />6 <br />0.06 <br />0.75 <br />0.16 <br />1.81 <br />SUM <br />0.39 <br />4.50 <br />0.94 <br />10.88 <br />Load Combinations <br />(LRFD) <br />Sec. 2.2 <br />Axial Load <br />Combin- <br />Factor <br />DL <br />Factor <br />PL <br />Factor <br />LL <br />Factor <br />EL <br />Total <br />ation <br />(K) <br />(K) <br />(K) <br />(K) <br />Pr <br />2 <br />1.20 <br />0.39 <br />1.40 <br />4.50 <br />1.60 <br />- <br />6.77 <br />5 <br />1.42 <br />0.39 <br />0.99 <br />4.50 <br />0.50 <br />- <br />1.00 <br />- <br />5.03 <br />7 <br />0.68 <br />0.39 <br />0.68 <br />4.50 <br />- <br />- <br />1.00 <br />- <br />3.32 <br />