My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2 W CASINO RD 2022 BLDG F Plans 2025-04-07
>
Address Records
>
W CASINO RD
>
2
>
BLDG F
>
Plans
>
2 W CASINO RD 2022 BLDG F Plans 2025-04-07
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/7/2025 7:40:11 AM
Creation date
4/7/2025 7:39:47 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
2
Tenant Name
BLDG F
Permit
B2211-070
Year
2022
Notes
BLDG F - PROPOSED REPAIR OF DAMAGED STAIRS, WALKWAY, SOFFIT
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES: <br /> 1.Verify all conditions in the field. <br /> '` �`F KILBURN <br /> v PoSr NOTE: <br /> FULLY SOLDERED ALL JOINT <br /> M"Osr ARCHITECTS LLC <br /> Et <br /> A <br /> 135 Lake Street South <br /> Suite 250 <br /> Kirkland,WA 98033 <br /> BOTTOM FLANGE OF VENT NOTE:WHERE MULTIPLE VENTS NEW PT.GLB PER STRUCTURAL <br /> q COLLAR SHALL COVER TOP OCCUR,GANG UNDER ONE ELF 2Tel:206.682.5211 <br /> OF SIDING,V.I.F. HOOD.VERIFY WITH ARCHITECT. STAIR PER <br /> 2-PIECE SADDLE FLASHING &^ Fax:206.682.1403 <br /> \FH I <br /> EXTEND 3' 5i STRUCTURAL-- -., +-"�' NEW 518"7YPE'X'GYPSUM BOARD <br /> SLEEVE 4"MIN. S�pl ,, —.kilburnarchitects.com <br /> A v OVER V"" 1. <br /> O <br /> EXISTING <br /> DUCT I <br /> EXISTING OR NEW 5I8"TYPE 7302 <br /> ` X GYPSUM SHEATHING RECiSTEREO <br /> SLOPE I �NEW BEAM PER STRUCTURAL � �CHiTECT <br /> BOTTOM AND EXISTING OR NEW VENTED VINYL <br /> TOP FLANGES ° I 24GA.METAL DECK EDGE FLASHING SOFFIT,TYP. <br /> I W1 112"HEMMED DRIP EDGE H.TODD KILBURN <br /> T �$ ---- EXISTING OR NEW VINYLVCHANNEL TO MATCH STATE OF�ASeINOTON <br /> -X—X- N 555"' ° EXISTING ... . <br /> VENT FLASHING � NEW PLYWOOD SHEATHING <br /> COLLAR ISOMETRIC REMOVABLE VENT EXISTING OR NEW VINYL V CHANNEL TO MATCH NEW W.R.B,TYP. <br /> I WALKWAY FRAMING PLAN <br /> -{---5"" COVER.ATTACH WITH �PERSTRUCTURAL EXISTING NEW LAP SIDING <br /> GASKETED FASTENERS EXISTING OR NEW VENTED VINYL PROVIDE 1/8"SEALANT GAP AT SIDING I TRIM JOINT PER <br /> VENT COVER ISOMETRIC O NEW 2-PIECE 24 GA.METAL SADDLE SOFFIT,TYP. MANUFACTURER'S SPECIFICATIONS,APPLY SEALANT <br /> ISOMETRICS NOT TO SCALE <br /> FLASHING WRAP-HEM ALL EXPOSED EXISTING OR NEW 518"TYPE'X'GYPSUM NEW 1 X FIBER-CEMENT TRIM,ALIGN WITH POST ABOVE TO <br /> EXISTING POST EDGES,-SET IN SEALANT,TYP. SHEATHING MATCH EXISTING ELEVATION <br /> NEW 1 X 2 TRIM TO MATCH EXISTING <br /> O EXISTING ORSHEATHING NEW 518"TYPE <br /> 'X'GYPSUM EXISTING OR NEW VINYL'J'CHANNEL TO MATCH <br /> — EXISTING <br /> PLAN VIEW <br /> 24GA,METAL EDGE FLASHING W/ <br /> 112"HEMMED DRIP EDGE <br /> Vent Collar and Cover-Isometim Saddle Flashing at Base of Post Vinyl Soffit Termination under Stair Siding Transion <br /> Sms N.T.S L Scale:3"=1'-0" �`�J Scale:3"=1'-0" `t Scale:3"=1'-0" <br /> Bluffs at Evergreen <br /> Walkway Repair <br /> (Bldg.F) <br /> 2 West Casino Road <br /> Everett,WA 98024 <br /> NEW PT.B X 6 POST PER STRUCTURAL BEYOND Release Date <br /> permit 11.4.2022 <br /> SECTION <br /> NEW PT.2 X 8 CAP WI SLOPE <br /> NEW POST PER STRUCTURAL <br /> SECTION <br /> PLANE TOPPING SLAB EDGE TO SEALANT NEW PT.POST PER STRUCTURAL,-PAINT <br /> 6 <br /> ACCEPT FLASHING <br /> NEW SELF-ADHESIVE FLASHING MEMBRANE <br /> NEW WATERPROOF DECK <br /> 'Y COATING-INSTALL PER NEW CONCRETE TOPPING SLAB PER STRUCTURAL <br /> NEW PT.GLB PER STRUCTURAL MANUFACTURER'S <br /> SPECIFICATIONS <br /> z V.I.F FLASHING <br /> HEMMED <br /> DRIP EDGE,SET IN BED OF SEALANT <br /> s <br /> NEW 24 GA,2-PIECE METAL <br /> NEW IXCEDAR BLOCKING AS REQUIRED SADDLE FLASHING,-SET IN <br /> s^ SEALANT,SEE DETAIL#2/A-2.2 <br /> _ NEW WATERPROOF DECK COATING- <br /> NEW 2X2 PICKET PER STRUCTURAL <br /> NEW CONCRETE TOPPING SLAB INSTALL PER MANUFACTURER'S <br /> 4" TO MATCH EXISITNG SPECIFICATIONS <br /> FRAMING PER <br /> NEW IX FIBER-CEMENT TRIM 4 d' <br /> ,.: — - ��• <br /> STRUCTURAL NEW WAS,TYR <br /> EXTERIOR � <br /> WALKWAY p NEW SHEATHING PER STRUCTURAL SHEATHIN PE ITRUCTURAL <br /> WALKWAY <br /> FRAMING PER <br /> STRUCTURAL <br /> Details <br /> Railing Top-Section � Flashing wl Post at Walkway Edge Flashing wl Post at Walkway Edge <br /> Scale:3"=1'-0" v Scale:3"=1'-0^ Scale:3"=1'-0^ CITY OFEVERETT <br /> REVIEWED FOR PERMIT <br /> A-2.2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.