INTEGRATED 24 HR WHOLE N I A SYSTEM <br /> Window,Skylight and Door Schedule M1507.1 GENERAL LOCAL EXHAUST OR WHOLE-HOUSE MECHANICAL MECHANICAL HEATING EQUIPMENT <br /> Pmject Information Contact Information VENTILATION SYSTEMS AND EQUIPMENT SHALL BE DESIGNED IN ACCORDANCE ALL WARM-AIR FURNACES SHALL BE LISTED AND LABELED BY AN NO <br /> Lot 50 Cohasset Beach a En Washington State Energy Cede Residential REVISIONS: <br /> LENTZ DESIGNS Prescriptive Energy Code Compliance for All Climate Zones in Washington WITH THIS SECTION. WARM-AIR FURNACES SHALL BE INSTALLED IN A ROOM USED OR DESIGNED <br /> xxxx South Cohasset st 26506 187th Ave SE Single Family New&Additions(effective February 1,2021) TO BE USED AS A BEDROOM, BATHROOM, CLOSET OR IN ANY ENCLOSED DATE: xx-xx-xx <br /> lWestport We.98595 ICOVINGTON,WA 9BD42 M1507.2 RECIRCULATION OF AIR EXHAUST AIR FROM BATHROOMS AND TOILET SPACE WITH ACCESS ONLY THROUGH SUCH ROOM OR SPACE, EXCEPT DIRECT <br /> ROOMS SHALL NOT BE RECIRCULATED WITHIN A RESIDENCE OR TO ANOTHER VENT FURNACE, ENCLOSED FURNACES AND ELECTRICAL HEATING FURNACES. <br /> Width Height These requirements apply to all IRC building types,including detached one-and two-family EXH UST AIRLLING T AND SHALL BE FROM BATHROOMS RAND STED TOILLETDIRECTLY TO THE OUTDOORS.ROOMS SHALL NOT DISCHARGE NQAEP PIT. BASEMENTMORASIMIILARNING OCAT10N APPLIANCES <br /> WHERE HEAVIER THAN IA AIR GASD <br /> dwellings and multiple single-family dwellings(townhouses).Ref.U-factor Qt.Feet Inch Feet Inch Area UA INTO AN ATTIC CRAWL SPACE OR OTHER AREAS OF THE BUILDING. MIGHT COLLECT. APPLIANCES SO FUELED SHALL NOT BE INSTALLED IN AN <br /> Exempt Swinging Door(:24 sq.ft.max.) 0.0 0.00 Proect lnrormet/on Contact ABOVE GRADE UNDER FLOOR SPACE OR BASEMENT UNLESS SUCH LOCATION <br /> Lot 26 Cohasset Beach M1507.3 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM WHOLE-HOUSE IS PROVIDED WITH AN APPROVED MEANS FOR REMOVAL OF UNBURNED GAS. <br /> Exempt Glazed Fenestration(15 sq.R max.) 0.0 0.00 xxxx South Cohasset at 126506187th Ave SE COVINGTON WA.98042 MECHANICAL VENTILATION SYSTEMS SHALL BE DESIGNED IN ACCORDANCE HEATING AND COOLING EQUIPMENT LOCATED IN A GARAGE WHICH GENERATES <br /> WITH SECTIONS M1507.31 THROUGH M1507.3.3 A GLOW, SPARK OR FLAME CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL <br /> Vertical Fenestration(Windows and doors) Instructions:This single-family project will use the requirements of the Prescriptive Path below and BE INSTALLED WITH THE PILOTS AND BURNERS FOR HEATING ELEMENTS AND <br /> incorporate the minimum values listed.Based on the size of the structure,the appropriate number of M1507.3.1 SYSTEM DESIGN EACH DWELLING UNIT OR GUESTROOM SHALL BE SWITCHES AT LEAST 18"ABOVE THE FLOOR LEVEL. <br /> Component Width Height additional credits are checked as chosen by the permit applicant. EQUIPPED WITH A VENTILATION SYSTEM COMPLYING WITH SECTION M150.3.4, <br /> Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and M1507.3.6, OR M1507.3.7 COMPLIANCE IS ALSO PERMITTED TO BE TEMPERATURE CONTROL <br /> Fenestration Requirements by Component,Table R406.2-Fuel Normalization Credits and 406.3-Energy Credits. DEMONSTRATED THROUGH COMPLIANCE WITH THE INTERNATIONAL MECHANICAL THE PRIMARY SPACE CONDITIONING SYSTEM `WITHIN EACH DWELLING UNIT <br /> A 0.28 3 70 48 70.0 21.00 q 9y CODE OR ASHRAE STANDARD 62.2. SHALL BE PROVIDED WITH AT LEAST ONE PROGRAMMABLE THERMOSTAT FOR <br /> 0.28 <br /> Au OdzBd Representative DWIGHT LENTZ-LENTZ DESIGNS Date 03/73/2022 THE REGULATION OF TEMPERATURE WSEC SEC.403.1.1 <br /> 0.28 M1507.3.2 CONTROL AND OPERATION <br /> 028 1. LOCATION OF CONTROLS. CONTROLS FOR ALL VENTILATION SYSTEMS VENTILATION <br /> All Climate Zones(Table R402.1.1) SHALL BE READILY ACCESSIBLE BY THE OCCUPANT. EVERY FACTORY BUILT CHIMNEY, TYPE, L VENT, TYPE B GAS VENT OR TYPE <br /> 028 R-Vew. usaw. 2. INSTRUCTIONS. OPERATING INSTRUCTIONS FOR THE WHOLE-HOUSE B GAS BENT SHALL BE INSTALLED IN ACCORDANCE WITH THE TERMS OF ITS <br /> 0.28 Fenestration U-Factorb We 0.30 VENTILATION SYSTEMS SHALL BE PROVIDED TO THE OCCUPANT BY THE LISTING, MFR'S A TYPE L VENTING SYSTEM SHALL TERMINATE NOT LESS THAN <br /> SkylightU-Factorb Ma 0.50 0.P8INSTALLER OF THE SYSTEM. 2 FEET ABOVE THE HIGHEST POINT WHERE THE VENT PASSES THROUGH THE <br /> 3. LOCAL EXHAUST SYSTEMS. LOCAL EXHAUST SYSTEMS SHALL BE ROOF OF THE BUILDING AN AT LEAST 2' HIGHER THAN ANY PORTION OF THE <br /> 0.28 Glazed Fenestration SHGC b,e n/a Na CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS, OR OTHER BUILDING WITHIN 10'OF THE VENT. <br /> 0.28 Caine. w1 0.026 APPROVED MEANS. xn <br /> Wood Frame Wall g, 21 int 0.056 4. CONTINUOUS WHOLE-HOUSE VENTILATION SYSTEMS. CONTINUOUS <br /> 0.28 UTILITY ROOM NOTES/MAKE UP AIR: >� <br /> Floor 30 0.029 WHOLE-HOUSE VENTILATION SYSTEMS SHALL OPERATE CONTINUOUSLY rn <br /> 0.28 Below Grade Wall c,h 10/15121 int+TB 0.042 AND BE EQUIPPED WITH AN OVERRIDE CONTROL A"FAN ON" SNATCH 1. WHERE THE EXHAUST DUCT IS CONCEALED N1hIIN THE BUILDING <br /> 0.28 SHALL BE PERMITTED AS AN OVERRIDE CONTROL CONTROLS SHALL BE CONSTRUCTION THE EQUIVALENT LENGTH OF THE EXHAUST DUCT SHALL N <br /> BE IDENTIFIED ON A PERMANENT LABEL. OR TAG. THE LABEL OR TAG a <br /> 0.28 2018 Washington State Energy Cede Residential CAPABLE OF OPERATION THE VENTILATION SYSTEM W/O ENERGIZING SHALL BE LOCATED WITHIN 6 FT OF THE EXHAUST DUCT CONNECTION. 'c LLI 00 <br /> 0 28 Prescriptive Energy Code Compliance for All Climate Zones in Washington OTHER ENERGY-CONSUMING APPLIANCES. A CLEARLY VISIBLE LABEL 2. INSTALLATIONS EXHAUSTING MORE THAN 200 CFM SHALL BE PROVIDED J rn <br /> Single Family New&Additions(effective February 1,2021) SHALL BE AFFIXED TO THE CONTROLS THAT READS WHOLE-HOUSE WITH MAKE-UP AIR WHERE A CLOSET IS DESIGNED FOR THE LU <br /> Sum of Vertical Fenestration Area and UA 70.0 21.00 VENTILATION (SEE OPERATION INSTRUCTIONS)". INSTALLATION OF A CLOTHES DRYER, AN OPENING HAVING AN AREA OF N U) >Q <br /> Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2(fuel 5. INTERMITTENT WHOLE-HOUSE VENTILATION SYSTEMS. INTERMITTENT NOT LESS THAN 100 s INCHES FOR MAKE UP AIR SHALL BE PROVIDED CD Z Q Ln Vertical Fenestration Area Weighted U=UA/Area 0.28 normalization credits and Table 406.3(energy y credits)to achieve the followin minimum number ofq' N (7 <br /> permit 9 FOLLOWING: <br /> WHOLE-HOUSEWING: VENTILATION SYSTEMS SHALL COMPLY WITH THE IN THE CLOSET ENCLOSURE, OR MAKE UP AIR SHALL BE PROVIDED BY -Z <br /> credits.To claim this credit,the building permit drawings shall specify the option selected and the H !q p <br /> FOLLOWING: OTHER APPR. MEANS. n r3 <br /> Overhead Glazingmaximum tested building air leakage,and show the qualifying ventilation system and its control sequence 5.1 THEY SHALL BE CAPABLE OF OPERATING INTERMITTENTLY = 111 °D H <br /> of operation. -100 sq. INCHES TRANSFER GRILL PER IRC G2439.4(614.6) (� .. 0 U CD <br /> AND CONTINUOUSLY. CDComponent Width Height " N Z <br /> 1.Small Dwelling Unit:3 credits 5.2 THEY SHALL HAVE CONTROLS CAPABLE OF OPERATING THE � a w �- <br /> Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA Dwelling units less than 1,500 sf in conditioned floor area with less than 300 sf of fenestration area. EXHAUST FANS, FORCED-AIR SYSTEM FANS, OR SUPPLY FANS d Z > <br /> 0.0 0.00 Additions to existing building that are greater than 500 sf of heated floor area but less than 1,500 sf. W/O ENERGIZING OTHER ENERGY-CONSUMING APPLIANCES. U LU a ID O <br /> LO <br /> 0.0 0.00 2.Medium Dwelling Unit:6 credits 5.3 THE SYSTEM SHALL BE DESIGNED SO THAT IT CAN CONTINUOUS WHOLE-HOUSE (� <br /> All dwelling units that are not included in#1 or#3 OPERATE AUTOMATICALLY BASED ON THE TYPE OF CONTROL <br /> 0.0 0.00 3.Large Dwelling Unit:7 credits DWELLING LINT AREA NUMBER OF BEDROOMS <br /> Dwelling units exceeding 5,000 sf of conditioned floor area TIMER INSTALLED. m 50�T.) <br /> 0.0 0.00 5.4 THE INTERMITTENT MECHANICAL VENTILATION SYSTEM SHALL <br /> 4.Additions less than 500 square feet:above <br /> credits o-+ z-3 - s-7 - <br /> OPERATE AT LEAST ONE HOUR OUT OF EVERY FOUR. <br /> 0.0 0.00 All other additions shall meet 1-3 above Airflow in CFM <br /> 5.5 THE SYSTEM SHALL HAVE A MANUAL CONTROL AND -lsoo 3o As so 75 yo <br /> 0.0 0.00 Before selecting your credits on this Summary table,review the details in Table 406.3(Single Family),on page 4. AUTOMATIC CONTROL, SUCH AS A 24-HOUR CLOCK TIMER. <br /> 5.6 AT THE TIME OF THE FINAL INSPECTION, THE AUTOMATIC 1501-3000 45 eo )s So IM <br /> Sum of Overhead Glazing Area and UA 0.0 0.00 Summary of Table R406.2 CONTROL SHALL BE SET TO OPERATE THE WHOLE-HOUSE FAN Scam-.Sao Bo 7s Bo fps 120 <br /> Heating Credits-select ONE ACCORDING TO THE SCHEDULE USED TO CALCULATE THE Asm_BOpO is w Its 120 1. <br /> Overhead Glazing Area Weighted U=UA/Area 0.00 Option i Fuel Normalization Descriptions heating option User Notes WHOLE-HOUSE FAN SIZING. N <br /> 1 Combustion heating minimum NAECAb 0.0 ❑ 5.7 A LABEL SHALL BE AFFIXED TO THE CONTROL THAT READS eom-7500 ao 1. 1. 13s ISO <br /> Total Sum of Fenestration Area and LIA(for heating system sizing calculations) 2 Heat pumpc 1.0 ❑ "WHOLE-HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)". 7600-UP 1. 12. 136 150 1. <br /> INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORS l� <br /> 3 Electric resistance heat only-furnace or zonal -1.0 ❑ M15073.21 OPERATING INSTRUCTIONS INSTALLERS SHALL PROVIDE THE RUN-ME xIN <br /> 4D Pwith zonal electric resistance per option 3.4 0.5 ❑ MANUFACTURER'S INSTALLATION, OPERATING INSTRUCTIONS, AND A uSEGMEM a 25.00% 3xomr so.aox ea.aos 7aaos +m.00x <br /> 5 All other heating systems -1.0 ❑ WHOLE-HOUSE VENTILATION SYSTEM OPERATION DESCRIPTION. FACTOR v1 <br /> Brindle HeatingSystem Size:Washington State Credits-select ONE EACTaH a 3 z 1.s 1.3 i.o <br /> This re tin s tern izin r b on the Pr n iv it 1 w shin ton state Ener Code WSEc and ACCA Energy Energy Credit Option Descriptions energy opton from as h M1507.3.3 MECHANICAL VENTILATION RATE THE WHOLE-HOUSE MECHANICAL MINIMUM REQUIRED I HAUST RAM W <br /> Manuals J and S.This calculator will Calculate heatina loads onl.ACCA Pmcaduma for sizino coolino systemsshould be used to determine wolinoOption VENTILATION SYSTEM SHALL PROVIDE OUTDOOR AIR TO EACH DWELLING UNIT <br /> loads. 1.1 Efficient Building Envelope 0.5 ❑ AT A CONTINUOUS RATE OF NOT LESS THAN THAT DETERMINED IN AREA TO BE VENTED DBIAUST RATES <br /> Please 1.2 Efficient Building Envelope 1.0 ❑ ACCORDANCE WITH TABLE M1507.3.3 1 x10,ms IN CM INTERMITTENT OR H <br /> some values will <br /> all of thegreendfop-0ownsou boxes thatareapplicableu your projectop As youmake se,pleasinthe drop-downs foreach sector, 1.3 Efficient Building Envelope 0.5 ❑ EXCEPTION: THE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM IS 25CFM carmN000S-Y <br /> hies will be calculated for you.If you do not See the selection you need in the drop-down options,please CaII Me WBU Energy Extension 9 Pe 5o act WTERMITIDIT OR <br /> Program at(360)956-2042 for assistance. 1.4 Efficient Building Envelope 1.0 ❑ PERMITTED TO OPERATE INTERMITTENTLY WHERE THE SYSTEM HAS CONTROLS BATHROOMMUNDRY/SWILAR AREAS 200"'OONTNU_ <br /> 1.5 Efficient Building Envelope 2.0 ❑ THAT ENABLE OPERATION FOR NOT LESS THAN 25X OF EACH 4-HOUR <br /> Pro ecc lnromlation Contact Information 1.8 Eficient Building Envelope 3.0 ❑ SEGMENT AND THE VENTILATION RATE PRESCRIBED IN TABLE M1507.3.3(2) AIR LEAKAGE <br /> lM 50 Cohasset Beach PaciRc NW Oesl n antl Build INC. <br /> Avg South Cohassetn 1562684th AveE 1.7 Efficient Building Envelope 0.5 ❑ M1507.3.5 WHOLE-HOUSE VENTILATION INTEGRATED WITH A FORCED-AIR IECCwen rtwa.98595 pu allu WA 98375 2.1 Air Leakage Control and Efficient Ventilation 0.5 ❑ SYSTEM. THIS SECTION ESTABLISHES MINIMUM PRESCRIPTIVE REQUIREMENTS THE /WA STATE R AL E AIR LEAKAGE BE CONSTRUCTED <br /> Heating System Type: xAll rnnesve.na Hex Camp 2.2 Air Leakage Control and Efficient Ventilation 1.0 ❑ FOR WHOLE-HOUSE VENTILATION SYSTEMS INTEGRATED WITH FORCED-AIR THE BUILDING THERMAL ENVELOPE SHALL BE CONSTRUCTED TO <br /> VENTILATION SYSTEMS. A SYSTEM WHICH MEETS ALL THE REQUIREMENTS OF LIMIT AIR LEAKAGE IN ACCORDANCE WITH THE REQUIREMENTS OF <br /> To.Design emperattor eau,:action,Plane your wlsor on the word^Insuuctiens•. 2.3 Air Leakage Control and Efficient Ventilation 1.5 ❑ THIS SECTION SHALL BE DEEMED TO SATISFY THE REQUIREMENTS FOR A SECTIONS R 402.4.1 THROUGH R402.4.4. <br /> Design Temperature 2.4 Air Leaka a Control and Efficient Ventilation 2.0 1 ❑ WHOLE-HOUSE VENTILATION SYSTEM. LUDesign Temperature Difference(AT) 51 R402.4.1.2 THE BUILDING OR DWELLING UNIT SHALL BE TESTEDM1507 p <br /> AT eapp,vo a»a»y auMp.roaep.r..,+ 3.ia HighEffiden HVAC 1.0 AND VERIFIED AS HAVING AN AIR LEAKAGE RATE OF NOT <br /> Area of Building WHOLE J <br /> 3.2 High Efficiency HVAC 1.0 ❑ WHOLE 3.O INTEGRATED WHOLE-HOUSE VENTILATION SYSTEMS, INTEGRATED LU <br /> HOUSE VENTILATION SYSTEMS SHALL PROVIDE OUTDOOR AIR AT THE EXCEEDING 5 AIR CHANGES PER HOUR. TESTING SHALL BE <br /> Conditioned Floor Area 3.3e High Efficiency HVAC 1.5 ❑ RATE CALCULATED USING SECTION M1507.3.3. INTEGRATED WITH FORCED-AIR CONDUCTED WITH A BLOWER DOOR AT A PRESSURE OF 0.2 m <br /> Conditioned Floor Ama(sq ft) 2,412 3A High Efficien HVAC 1.5 ❑ VENTILATION SYSTEMS SHALL DISTRIBUTE OUTDOOR AIR TO EACH HABITABLE INCHES W.G. (50 PASCALS). WHERE REQUIRED BY THE CODE 0 <br /> Average Ceiling Height Conditioned volume 3.5 High Efficien HVAC 1.5 ❑ SPACE THROUGH THE FORCED-AIR SYSTEM DUCTS. INTEGRATED FORCE-AIR OFFICIAL, TESTING SHALL BE CONDUCTED BY AN APPROVED THIRD E <br /> Average Ceiling Height(ft) 1D.o 24,120 3.6s High Efficienc HVAC 2.0 ❑ VENTILATION SYSTEMS SHALL HAVE AN OUTDOOR AIR INLET DUCT PARTY. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL N <br /> Glazing and Doors U-Factorx Area = UA CONNECTING A TERMINAL ELEMENT ON THE OUTSIDE OF THE BUILDING TO BE SIGNED BY THE PARYT CONDUCTING THE TEST AND PROVIDED <br /> 4.1 High Efficiency HVAC Distribution System 0.5 ® THE RETURN OF AIR PLENUM OF THE FORCED-AIR SYSTEM. AT A POINT TOT HE CODE OFFICIAL. TESTING SHALL BE PERFORMED AT ANY v <br /> 0.300 676 172.80 4.2 High Efficiency HVAC Distribution System 1.0 ❑ WITHIN 4FT UPSTREAM OF THE AIR HANDLER. THE OUTDOOR AIR INLET DUCT TIME AFTER CREATION OF ALL PENETRATIONS OF THE BUILDING <br /> Skylights ufaMorx area UA CONNECTION TO THE RETURN AIR STREAM SHALL BE LOCATED UPSTREAM OF THERMAL ENVELOPE. ONCE VISUAL INSPECTION HAS CONFIRMED v <br /> THE FORCED-AIR SYSTEM BLOWER AND SHALL NOT BE CONNECTED DIRECTLY SEALING(SEE TABLE R02.4.1.1) OPERABLE WINDOWS AND DOORS <br /> 0.50 O - Energy Credits-select N <br /> a Energy Credit Option Descriptions(cont.energy option fro User Notes TO A FURNACE CABINET TO PREVENT THERMAL SHOCK TO THE HEAT MANUFACTURED BY SMALL BUSINESS SHALL BE PERMITTED TO BE d1 <br /> insulation Option each category d EXCHANGER THE SYSTEM WILL BE EQUIPPED WITH A MOTORIZED DAMPER SEALED OFF AT THE FRAME PROIR TO THE TEST. a' O <br /> Attic U-Fectorx Area = UA CONNECTED TO THE AUTOMATIC VENTILATION CONTROL AS SPECIFIED IN ♦-N <br /> 5.1d Efficient Water Heating 0.5 ❑ <br /> o.a26 369 3s.ss SECTION M7507.3.2. THE REQUIRED FLOW RATE SHALL BE VERIFIED BY FIELD DURING TESTING: U LUo0 <br /> 5.2 Efficient Water Heating 0.5 ® Z W OT <br /> TESTING WITH A FLOW HOOD OR A FLOW MEASURING STATION. 1. EXTERIOR WINDOWS AND DOORS, FIREPLACE AND STOVEIx <br /> Single Rarer or ufaaorx Area uA 5.3 Eficient Water Heating 1.0 ❑ DOORS SHALL BE CLOSED, BUT NOT SEALED, BEYOND THE <br /> 0 5.4 Efficient Water Heating 1.5 ❑ M15073.5.2. VENTILATION DUCT INSULATION. ALL SUPPLY DUCTS IN THE INTENDED WEATHER STRIPPING OR OTHER INFILTRATION <br /> n.w.Oaa,w,n.I»ADase1L�� ufaMorx Area UA 5.5 Efficient Water Heating 2.0 ❑ CONDITIONED SPACE SHALL BE INSULATED TO A MINIMUM OF R-4. CONTROL MEASURES. 55 L- <br /> II 0.os5 0 5.e Efficient Water Heating 2.5 ❑ 2. DAMPERS INCLUDING EXHAUST, INTAKE, MAKEUP AIR, fn 7 W <br /> M1507.3.5.3 OUTDOOR AIR INLETS INLETS SHALL BE SCREENED OR THERE BACKDRAFT AND FLUE DAMPERS SHALL BE CLOSED, BUT <br /> Ploors U-Factorx Area UA 8.1e Renewable Electric Energy(3 credits max) 1.0 U 0 <br /> WISE PROTECTED FROM ENTRY BY LEAVES OR OTHER MATERIAL OUTDOOR NOT SEALED BEYOND INTENDED INFILTRATION CONTROL d' N W <br /> 0.029 z,a12 69.9s 7.1 Appliance Package 0.5 AIR INLETS SHALL BE LOCATED SO AS NOT TO TAKE AIR FROM THE MEASURES. 0 LO> <br /> Total Credits LLN 11 CLEAR FORM I FOLLOWING AREAS: 3. INTERIOR DOORS, IF INSTALLED AT THE TIME OF THE TEST, p LO W <br /> e.N"oa»w.II.( U-Factorx Area UA 1. CLOSER THAN 10 FT FROM AN APPLIANCE VENT OUTLET, UNLESS SHALL BE OPEN, ACCESS HATCHES TO CONDITIONED CRAWL <br /> a.An alternative healing source sized at a maximum of 0.5 W/sf(equivalent)of heated floor area or 500 W, <br /> 0.0za 2,7as 76.69 SUCH VENT OUTLET IS 3FT ABOVE THE OUTDOOR AIR INLET. SPACES AND CONDITIONED ATTICS SHALL BE OPEN. <br /> whichever is bigger,may be installed in the dwelling unit. 2. WHERE IT WILL PICK UP OBJECTIONABLE ODORS, FUMES OR FLAMMABLE 4. EXTERIOR OPENINGS FOR CONTINUOUS VENTILATION SYSTEMS <br /> F-Faworx Len h UA b. VAPORS. AND HEAT RECOVERY VENTILATORS SHALL BE CLOSED AND <br /> Equipment listed in Table C403.3.2(4)or C403.3.2(5) S <br /> 0.303 t - c.Equipment listed in Table C403.3.2(1)or C403.3.2(2) <br /> 3. A HAZARDOUS OR UNSANITARY LOCATION. SEALED. <br /> d.You cannot select more than one option from any category EXCEPT in category 5.Option 5.1 may be combined y <br /> sl.e p.Daa.I.»Ra F-Factorx Lend J UA with tions 5.2 through 5.6.See Table 406.3. 4. A ROOM SPACE HAVING ANY FUEL-BURNING APPLIANCES THEREIN. 5. HEATING AND COOLING SYSTEMS, IF INSTALLED AT THE TIME <br /> P 9 5. CLOSER THAN 10FT FROM A VENT OPENING OF A PLUMBING DRAINAGE OF THE TEST, SHALL BE TURNED OFF, AND <br /> a.1.0 credit for each 1,200 kWh of electrical generation provided annually,up to 3 credits max. SYSTEM UNLESS THE VENT OPENING IS AT LEAST 3FT ABOVE THE AIR 6. SUPPLY AND RETURN REGISTERS, IF INSTALLED AT THE TIME <br /> See the complete Table R406.2 for all requirements and option descriptions. INLET. OF THE TEST, SHALL BE FULLY OPEN. <br /> Location of Ducts 6. ATTIC, CRAWL SPACES, GARAGES. <br /> Duct Leakage Coefficient R402.4.2 FIREPLACES. <br /> 1.10 M1507.4 LOCAL EXHAUST LOCAL EXHAUST SHALL BE PROVIDED IN EACH NEW WOOD-BURNING FIREPLACES SHALL HAVE CO..: <br /> Sum of UA 355.03 KITCHEN BATHROOM, WATER CLOSET, LAUNDRY ROOM, INDOOR SWIMMING TIGHT-FITTING FLUE DAMPERS AND OUTDOOR <br /> POOL, SPA, AND OTHER ROOMS WHERE WATER VAPOR OR COOKING ODOR IS COMBUSTION AIR. <br /> Envelope Heat Load 18,107 Stu Hour PRODUCED. LOCAL EXHAUST SYSTEMS SHALL BE DESIGNED TO HAVE THE R402.4.3 AIR LEAKAGE OF FENESTRATION. <br /> Figure 1. suaauAxAT CAPACITY TO EXHAUST THE MINIMUM AIR FLOW RATE DETERMINED IN WINDOWS, SKYLIGHTS AND SLIDING GLASS DOORS SHALL <br /> Air Leakage Heat Load 13,285 BN/Hour ACCORDANCE WITH THE TABLE M1507.4. HAVE AN AIR INFILTRATION RATE OF NO MORE THAN 0.3 ENERGY <br /> Building Design Heat Load 31,392 Btu/Hour CFM SQUARE FOOT(1.5 L/S/M2), AND SWINGING DOORS NO <br /> L,.--E...,1..,^.. M1507.4.1 LOCAL EXHAUST FANS EXHAUST FANS PROVIDING LOCAL EXHAUST MORE THAN 0.5 CFM PER SQUARE FOOT(2.6 L/S/M2), SHEET <br /> Building and Duct Heat Load M,531 Btu/Hour SHALL HAVE A MINIMUM FAN FLOW RATING NOT LESS THAN 50 cfm AT 0.25 WHEN TESTED ACCORDING TO NFRC 400 OR <br /> Du­nu,mnanl.,ae„­ BulldH.elmxl.lo INCHES WATER GAUGE FOR BATHROOMS, LAUNDRIES, OR SIMILAR ROOMS, AAMA/WDMA/CSA 101/I.S.2/A440 BY AN ACCREDITED, <br /> »a�muma as,m aNH..I lo..x, AND 100 cfm AT 0.25 INCHES WATER GAUGE FOR KITCHENS. INDEPENDENT LABORATORY AND LISTED AND LABELED BY <br /> Maximum Heath Equipment output Aa,341BW/Hour MANUFACTURERS' FAN FLOW RATINGS SHALL BE DETERMINED AS PER HVI THE MANUFACTURER. <br /> au,m.o moues H„I r,:•;x,Ys,„H„, p » 916 (APRIL 1995) OR AMCA 210. <br /> EXCEPTION: WHERE A RANGE HOOD OR DOWN DRAFT EXHAUST FAN <br /> (07/DI/13) IS USED TO SATISFY THE LOCAL EXHAUST REQUIREMENTS FOR EXCEPTIONS: DRAWN BY. OILKITCHENS, THE RANGE HOOD OR DOWN DRAFT EXHAUST SHALL NOT BE 1. FIELD-FABRICATED FENESTRATION PRODUCTS (WINDOWS, <br /> LESS THAN 10 cfm AT 0.10 INCHES WATER GAUGE. SKYLIGHTS AND DOORS). DATE: O'COM22 <br /> 2. CUSTOM EXTERIOR FENESTRATION PRODUCTS MANUFACTURED <br /> M1507.4.2 LOCAL EXHAUST CONTROLS LOCAL EXHAUST SYSTEMS SHALL BE BY A SMALL BUSINESS PROVIDED THEY MEET THE SCALE: 1/a•=ra• <br /> CONTROLLED BY MANUAL SWITCHES, DEHUMIDISTATS, TIMERS OR OTHER APPLICABLE PROVISIONS OF CHAPTER 24 OF THE PROJECT NUMBER A-0186 <br /> APPROVED MEANS. LOCAL EXHAUST SYSTEM CONTROLS SHALL BE READILY INTERNATIONAL BUILDING CODE. <br /> ACCESSIBLE. 3. CUSTOM EXTERIOR WINDOWS AND DOORS MANUFACTURED BY SHEETNO: <br /> A SMALL BUSINESS PROVIDED THEY MEET THE APPLICABLE <br /> PROVISIONS OF CHAPTER 24 OF THE INTERNATIONAL <br /> BUILDING CODE. ONCE VISUAL INSPECTION HAS CONFIRMED I� QV. <br /> THE PRESENCE OF A GASKET, OPERABLE WINDOWS AND „ <br /> DOORS MANUFACTURED BY SMALL BUSINESS SHALL BE <br /> PERMITTED TO BE SEALED OFF AT THE FRAME PRIOR TO <br /> THE TEST. <br /> ALL vARIATONS FROM OONDIMONS AND DIMENSIONS SHOWN ON THE DRAWING SHALL BE REPORTED TO THE DESIGNER FOR RESOWTON PRIOR OR PROCEEDING TO THE WORK OR OTHERWISE.THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE <br /> FOR COSTS OF ANY NECESSARY REMEDIAL WORK.REUSE OF DOCUMENTS UNAUTHORIZED ALTERATION OF MY OF THE INFORMATION ON THIS DOCUMENT WILL INVALIDATE THE DOCUMENT. <br /> THE IDEAS AND DESIGNS INCORPORATED HERON,AS AN INSTRUMENT OF PROFESSIONAL SERVICE IS THE PROPERTY OF NORTHWEST VINTAGE HOMES AND IS NOT TO BE USED IN MOLE OR IN PART,FOR ANY OTHER PROJECT WITHOUT WRITTEN AUTHORIZATION FROM NORTHWEST MNTAGE HOMES <br />