Laserfiche WebLink
TABLE R602.3(1) - FASTENING SC:HEI TT.F. <br /> ITEM DESCRIPTION OF BUILDING NUMBER AND TYPE OF SPACING AND LOCATION ITEM DESCRIPTION OF BUILDING NUMBER AND TYPE OF SPACING AND LOCATION 2018 WSEC - 6.0 CREDITS REQUIRED <br /> ELEMENTS FASTENERa,b,c ELEMENTS FASTENERa,h,c <br /> Heating Option 2-1.0 credits <br /> Roof Floor <br /> 4-8d box (2'/2" x 0.113")or 4-8d box(2'/2' x 0.113'); or 1.3-0.5 credits <br /> Blocking between ceiling joists or 3-8d common (2'/z" x 0.131')-, or 3- 3-8d common (2'/2' x 0.131"); or 3- Prescriptive compliance is based on Table R402.1.1 with the following modifications: <br /> , top plate or girder Toe nail vertical fenestration U =0.28 <br /> rafters to top plate 10d box (3" x 0.128"); or 10d box(3" x 0.128'); or Floor R-38 <br /> 3-3" x 0.131" nails 3-3' x 0.131' nails Slab on grade R-10 perimeter and under entire slab <br /> 4-8d box (2/2" x 0.113") or 8d box(2/2° x 0.113") 4", o.c. toenail Below grade slab R-10 perimeter and under entire slab <br /> ; <br /> , <br /> or <br /> 2 Ceiling joists to top plate 3-8d common (2'/z" x 0.131'); or 3- per joist toe nail 22 Rim joist, band joist or blocking to sill or 8d common (2%2" x 0.131'); or 10d Compliance based on Section R402.1.4: Reduce the Total conductive UA by 5%. <br /> 10d box(3" x 0.128'); or top plate (roof applications also) box(3' x 0.128"); or 6" o.c. toe nail <br /> 3-3" x 0.131" nails 3' x 0.131" nails 2.4-2.0 credits <br /> : <br /> Ceiling joist not attached to parallel 3-8d box(2/z" x 0.113"); or Compliance based on Section R402.4.1.2 � <br /> 4-10d box(3" x 0.128"),- or , Reduce the tested air leakage to 0.6 air changes per hour maximum at 50 Pascals .� <br /> rafter, laps over partitions � x 2-8d common (2/z" x 0.131"); or 3- or .^ <br /> 3 3-16d common (3/2' x 0.162')-, or 4- Face nail 23 1 " 6" subfloor or less to each joist Face nail C U) <br /> (see Section R802.52 and Table 3' x 0.131' nails 10d box(3" x 0.128"); or For R-2 Occupancies, optional compliance based on Section R402.4.1.2: Reduce the tested air leakage to 0.15 cfm/ft2 <br /> R802.5.2 2 staples, 1"crown, 16 ga., 13/" long maximum at 50 Pascals .� <br /> Ceiling joist attached to parallel rafter 3-16d box (3'/2" x 0.135"); or and (� <br /> 24 2" subfloor to joist or girder Blind and face nail All whole house ventilation requirements as determined by Section M1507.3 of the International Residential Code or •� Q <br /> (heel joint) 2-16d common 3/2' x 0.162" Section 403.8 of the International Mechanical Code shall be met with a heat recovery ventilations stem with minimum <br /> 4 Table R802.5.2 Face nail ry Y A(see Section R802.5.2 and Table 25 2" planks (plank& beam-floor& roof) 3-16d box (3'/2' x 0.135'); At each bearing, face nail or sensible heat recovery efficiency of 0.80. Duct installation shall comply with Section R403.3.7. <br /> , <br /> R802.5.2 2-16d Common 3/" x 0.162") To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the � M <br /> 3-16d common (3'/z" x 0.162")4-10 maximum tested building air leakage and shall show the heat recovery ventilation system. <br /> 4-10d box(3" x 0.128')- or `V <br /> Collar tie to rafter, face nail or 1'/4" x 20 box 3' x 0.128" , or L- <br /> ( � 3.5-1.5 credits <br /> 5 3-10d common (3" x 0.148"); or 4-3" Face nail each rafter i 26 Band or rim joist to joist End nail <br /> ga. ridge strap to rafter 4-3" x 0.131" nails; or Air-source, central) ducted heat um with minimum HSPF of 11.0. <br /> x 0.131' nails Y pump .^ <br /> 4-3" x 14 ga. staples, 7/16"crown To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the N• <br /> ' " x 0.135" ; or 3- Nail each layer as follows: 32' heating equipment type and the minimum equipment efficiency. 1 <br /> 3-16d box nails (3/2 ) 2 toe nails on one side and 1 y <br /> 10d common nails (3'x0.148"); or 4- 20d common (4' x 0.192'); or C.C. at top and bottom and 5.3-1.o credits <br /> 6 Rafter or roof truss to plate toe nail on opposite side of <br /> CNI <br /> 10d box 3' x 0.128" ; sta Bred. <br /> ( ) Water heating system shall include one of the following: <br /> each rafter or truss' 10d box 3" x 0.128" ; or 3° x 0.131" 24' o.c. face nail at to and Energy Star rated as or propane water heater with a minimum LIEF of 0.91 <br /> or 4-3" x 0.131" nails ( ) P gY g p p <br /> Built-up girders and beams, 2-inch <br /> 4-16d (3'/z" x 0.135")- or 27 nails bottom staggered on opposite or <br /> lumber layers And: Solar water heating supplementing a minimum standard water heater. Solar water heating will provide a rated minimum <br /> 3-10d Common (3" x 0.148"); Toe nail savings of 85 therms or 2000 kWh based on the Solar Rating and Certification Corporation(SRCC)Annual Performance <br /> Roof rafters to ridge, valley or hip <br /> or 4-10d box (3" x 0.128"), or 2-20d common (4' x 0.192'); or Face nail at ends and at each of OG-300 Certified Solar Water Heating Systems <br /> or 3" x 0.128"box ; <br /> 7 rafters or roof rafter to minimum 2" 4-3" x 0.131" nails 3-10d ( ) splice or <br /> 3-16d box 3'/2' x 0.135'); or 3-3" x 0.131" nails Water heater heated by ground source heat pump meeting the requirements of Option 3.3. <br /> ridge beam , 4-16d box 3'/2" x 0.135" ,- or To qualify to claim this credit,the building permit drawings shall specify the option being selected and shall specify the <br /> 10d b common (3/z" x 0.162°); or 3- ( ) water heater equipment type and the minimum equipment efficiency and,for solar water heating systems,the <br /> 10d box 3" x 0.128" ; or End nail 3-16d common (3/z" x 0.162"); or 4- <br /> ( ) 23 Ledger strip supporting joists or rafters At each joist or rafter, face nail calculation of the minimum energy savings. <br /> 3-3" x 0.131" nails 10d box (3" x 0.128'); or <br /> 4-3' x 0.131" nails <br /> DESCRIPTION OF BUILDING NUMBER AND TYPE OF 2-10d box(3" x 0.128'), or <br /> ITEM ELEMENTS FASTENERa,b,c SPACING AND LOCATION 29 Bridging or blocking to joist 2-8d common (2'/2' x 0.131"; or Each end, toe nail <br /> Wall 2-3" x 0.131'-, nails <br /> SPACING OF FASTENERS �- <br /> 16d common (3'/2" x 0.162") 24" o.c. face nail DESCRIPTION OF BUILDING NUMBER AND TYPE OF FASTENEW,b, Intermediate <br /> 8 Stud to stud (not at braced wall panels) ITEM Edges �- <br /> ELEMENTS supports` e <br /> 10d box(3" x 0.128"); or (inches)" (inches) o <br /> 3' x 0.131' nails 16° o.c. face nail <br /> Stud to stud and abutting studs at 16d box(3'/z" x 0.135"); or Wood structural panels, subfloor, roof and interior wall <br /> 12" o.c. face nail <br /> 9 intersecting wall corners (at braced 3' x 0.131' nails sheathing to framing and particleboard wall sheathing to framing <br /> wall panels) [see Table R602.3(3)for wood structural panel exterior wall sheathing to wall framing] <br /> 16d common (3'/z" x 0.162') 16' o.c. face nail <br /> 10 Built-up header(2"to 2" header with ''/2" 16d common (3'/2" x 0.162') 16' o.c. each edge face nail 6d common (2' x 0.113") nail (subfloor, <br /> spacer) 16d box(3'/z" x 0.135") 12" o.c. each edge face nail 33 3/$^ /Z" wall)'8d common (2'/z" x 0.131') nail 6 12' <br /> 5-8d box(2'/2' x 0.113"); or (roof); or RSRS-01 (2%' x 0.113") nail <br /> 11 Continuous header to stud 4-8d common (2'/2' x 0.131"); or 4- Toe nail (roof) <br /> 10d box(3' x 0.128")16d common (3'/2" x 0.162') 16' o.c. face nail O ,,11 '' <br /> ■�■ <br /> 8d common nail (2'/2" x 0.131"); or RSRS <br /> 12 Top plate to top plate 10d box(3' x 0.128"); or 31 19/32"-1" 6 12' <br /> 3' x 0.131' nails 12"o.c. face nail 01; (23/8" x 0.113°) nail (roofp <br /> 8-16d common (3'/2" x 0.162"); or 12- LU LU <br /> Face nail on each side of end 10d common (3" x 0.148") nail- or 8d >• <br /> 16d box(3'/z° x 0.135"); or � " � 6 12 +F-- <br /> 13 Double top plate splice joint (minimum 24' lap splice 32 1/� -1/" 2'/z^ x 0.131" deformed nail <br /> 12-10d box (3" x 0.128"); or length each side of end joint) ( ) O LU <br /> 12-3" x 0.131' nails Other wall sheathing9 _ <br /> Bottom plate to joist, rim joist, band 16d common (3'/2" x 0.162") 16' o.c. face nail 1'/2'galvanized roofing nail, 7/16' head <br /> i 4 joist or blocking (not at braced wall 16d box(3'/" x 0.135"); 12"or face nail /4 33 /2° structural cellulosic fiberboard diameter, or 1' " Ion le with 3 6 <br /> panels) 3" x 0.131" nails o.c. sheathing 7/16 g 16 ga. staple <br /> " or 1' crown <br /> 3-16d box(3'/z" x 0.135"); or 3 each 16'o.c. face nail <br /> Bottom plate to joist, rim joist, band , 13/4'galvanized roofing nail, 7/16" head <br /> 15 2-16d common (3/z' x 0.162'); or 4- 2 each 16' o.c. face nail 25/32'structural cellulosic fiberboard <br /> joist or blocking (at braced wall panel) 3" x 0.131' nails 4 each 16" o.c.face nail 34 diameter, or 1'/" long 16 ga. staple with 3 6 <br /> sheathing <br /> 4-8d box(2'/2' x 0.113")- or 7/16' or 1' crown <br /> 3-16d box (3'/z" x 0.135"); or 1'/2" galvanized roofing nail; staple <br /> 4-8d common (2'/2" x 0.131"); or 4- Toe nail 33 '/2'gypsum sheathing' galvanized, 1'/z' long-, 1'/' screws,Type 7 7 <br /> 10d box(3" x 0.128'); or W or S O <br /> 16 Top or bottom plate to stud 4-3' x 0.131' nails 13/4" galvanized roofing nail-, staple <br /> 3-16d box (3'/2" x 0.135'); or 36 V gypsum sheathing' galvanized, 15/' long- 1%' screws,Type 7 7 <br /> 2-16d common (3'/2' x 0.162"); or End nail I W or S <br /> 3-10d box (3" x 0.128')-, or Wood structural panels, combination subfloor underlayment to framing Q <br /> 3-3" x 0.131" nails 6d deformed (2' x 0.120") nail; or 8d O <br /> 37 3/4" and less 6 12 <br /> Top plates, laps at corners and 3-10d box(3" x 0.128"), or common (2'/2' x 0.131') nail r <br /> 17 2-16d common (3'/z' x 0.162"),- or 3- Face nail 8d common (2'/2' x 0.131") nail; or 8d <br /> intersections 38 '/8"-1" 6 12 <br /> 3" x 0.131" nails deformed (2'/z° x 0.120') nail <br /> 3-8d box (2'/2' x 0.113'); or 10d common (3' x 0.148") nail; or 8d <br /> 2-8d common (2'/2' x 0.131"); or 2- Face nail 39 1/e"-1,/4" deformed (2'/2° x 0.120') nail 6 12 <br /> 18 1" brace to each stud and plate <br /> 10d box(3' x 0.128"); or <br /> 2 staples 13/" For SI: 1 inch=25.4 mm, 1 foot=304.8 mm,1 mile per hour=0.447 m/s; 1 ksi=6.895 MPa. <br /> a.Nails are smooth-common,box or deformed shanks except where otherwise stated.Nails used for framing and sheathing connections shall <br /> 3-8d box(2'/2' x 0.113"); or have minimum average bending yield strengths as shown:80 ksi for shank diameter of 0.192 inch(20d common nail),90 ksi for shank <br /> 2-8d common (2'/2" x 0.131"); or 2- diameters larger than 0.142 inch but not larger than 0.177 inch,and 100 ksi for shank diameters of 0.142 inch or less. <br /> 19 1' x 6'sheathing to each bearing 10d box(3' x 0.128"); or Face nail b.Staples are 16 gage wire and have a minimum 7/16-inch on diameter crown width. <br /> c.Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater. <br /> 2 staples, 1'crown, 16 ga., 13/4" long d.Four-foot by 8-foot or 4-foot by 9-foot panels shall be applied vertically. <br /> e.Spacing of fasteners not included in this table shall be based on Table R602.3(2). CITY OF EVERETT <br /> 3-8d box(2'/z" x 0.113"); or f.For wood structural panel roof sheathing attached to gable end roof framing and to intermediate supports within 48 inches of roof edges and t� r-�R B <br /> 3-8d common (2'/2" x 0.1 31"); or 3- ridges,nails shall be spaced at 6 inches on center where the ultimate design wind speed is less than 130 mph and shall be spaced 4 inches on W�il E 1'�r E L} F©u� F E R itli!T Oq-23-2022 <br /> 10d box(3" x 0.128'), or center where the ultimate design wind speed is 130 mph or greater but less than 140 mph. <br /> 3 staples, 1"crown, 16 ga., 13/4" long g•Gypsum sheathing shall conform to ASTM C1396 and shall be installed in accordance with GA 253.Fiberboard sheathing shall conform to REV15 ED <br /> 1' x 8"and wider sheathing to each ASTM C208. <br /> 20 Wider than 1' x 8"4-8d box 2'/2" x Face nail h.Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required blocking and at floor 03-12-2023 <br /> bearing ( perimeters only.Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and required blocking. <br /> 0.113')-, or Blocking of roof or floor sheathing panel edges perpendicular to the framing members need not be provided except as required by other <br /> 3-8d common (2'/2' x 0.131"); or 3- provisions of this code.Floor perimeter shall be supported by framing members or solid blocking. <br /> 10d box(3" x 0.128"), or i.Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule,provide two toe nails on one side of the rafter <br /> 4 staples, 1" crown, 16 ga., 13/4" long and toe nails from the ceiling joist to top plate in accordance with this schedule.The toe nail on the opposite side of the rafter shall not be <br /> required. <br /> j.RSRS-01 is a Roof Sheathing Ring Shank nail meeting the specifications in ASTM F1667. <br />