Laserfiche WebLink
T CODE CALCULATIONS: �\ <br /> 1. REQUIRED EGRESS WIDTH: \� J <br /> 1.1. BUILDING IS FULLY SPRINKLERED(W/QR HEADS)STAIRS:0.2"/000UPANT <br /> 1 1.2. EGRESS WIDTHS REQUIRED PER IBC 1005.3.1&1005.3.2: <br /> 1.4. STAIRS:OMPONENTS: <br /> ' 1.4. OTHER COMPONENTS:0.2"/OCCUPANT <br /> 2. (2)MINIMUM EXITS REQUIRED PER IBC 1006.2.1/1006.3.2. W <br /> (B)EXITS HAVE BEEN PROVIDED. <br /> 3. "COMMON PATH OF EGRESS TRAVEL"FOR B OCCUPANCY TO BE 100'-0"OR <br /> LESS(75'-V WITHOUT OR SPRINKLERS THROUGHOUT BLDG)AS ALLOWED PER <br /> IBC TABLE 1006.2.1. T <br /> li �o <br /> L•�•� 4. "EXIT ACCESS TRAVEL DISTANCE"FOR B OCCUPANCY TO BE 300'-0"OR LESS ON <br /> fi" (200'-0"WITHOUT OR SPRINKLERS THROUGHOUT BLDG)AS ALLOWED PER IBC .�-. <br /> Pi RY TABLE 1017.2. U .� <br /> 4.1. EXIT TRAVEL DISTANCE SHALL BE MEASURED TO EXIT DISCHARGE OR Ln <br /> EXIT STAIR,BUT CONTINUE DOWN A EXIT ACCESS STAIR. LLI <br /> 5. DEAD-END CORRIDORS TO BE LESS THAN 20'-0".(50'-0"IF FULLY SPRINKLERED Z <br /> AND B4OCCUPANCY)PER IS 1020.4. j W <br /> c <br /> 2 N P <br /> SUITE A OCCUPANT LOAD: V a' <br /> REFER TO IBC TABLE 1004.5 FOR LOAD FACTOR N_ 3 <br /> Occupancy Room Name <br /> Room Square Load Occupan N <br /> ® n Number Footage Factor t Load � 0) <br /> 14 P OO <br /> S-1 WAREHOUSE 40,751 oS n 81.5 <br /> EXIT <br /> GENERAL <br /> 48 B OFFICE 1,388 si o 9.3 <br /> w ® a ® 5 4 4 B SERVER 111 176 — 0.6 Sports Art <br /> 4S' �— EXIT EXIT B BREAK ROOM 105 178 s 11.9 BRIDGE POINT EVERETT <br /> 46' 1(� TOTAL 42,493 103 500 <br /> L� 5900 36TH AVE WEST <br /> LEGEND: BLDG C-SUITE 100 <br /> EVERETT,WA 98203 <br /> COMMON PATH Of EGRESS TRAVEL <br /> ® EM E H E. <br /> IXITACCESS TRAVEL DISTANCE <br /> JXX OCCUPANT LOAD THROUGH OPENING <br /> N DESIGN JPC <br /> FJ(�7 PROTECTED EXIT DRAWN JC,TL <br /> ROOM USE <br /> pY � CHECKED JC <br /> ROOM U <br /> 101—ROOM NUMBER NO. 24-0187 <br /> N�- 0. B 200 SF ROOM AREA <br /> ® o ® o ® o EM o ® EM 1.150 1.3 0L OCCUPANT LOAD <br /> OCCUPANT LOAD FACTOR <br /> �SF,o I EXIT SIGN <br /> FIRE EXTINGUISHER <br /> TYP. <br /> THROUGHOUT CR CARD READER <br /> SCOPE OF ______________COMM N TH OF TRAVEL SUITE B FIRE-RATED WALLS <br /> WORK 9,�T,_,_._,_,�,.,.,.,.,.._,_,_,_,_ N.I.C.U.N.O. 82-5 _�i�DIAMOND QUANTITY INDICATES HOURLY RATING. <br /> ® ® EM + EM '---•—'—'—"S"INDICATES SMOKE PARTITION. <br /> WAREHOUSE112 I TYP. FLOOR PLAN KEYNOTES: <br /> Si 40751 SF I D NEW PAINT ONLY AT NEWWALL CONSTRUCTION. <br /> 1:500 81.50E <br /> IQ FULL HEIGHT R-8 BATi INSULATION.STICK PINNED TO CONCRETE PANEL,TYP. s4aS REGISTERED <br /> O HIGH BAY FIXTURES UNDER SEPARATE ELECTRICAL PERMIT.RELOCATE ANY ARCHITECT <br /> ® o ® n ® o I ® o EM ® 3 LIGHTS IN CONFLICT WITH NEW CONSTRUCTION. <br /> H <br /> W I OO PROVIDE AND INSTALL NEW EDGE OF DOCK LEVELER.SERCO SM7230. STATE OF WASNINGTON <br /> I O PROVIDE AND INSTALL MECHANICAL DOCK LEVELER WITH PIT.SERCO WL8700 <br /> 07 ______ _ ___________—\ <br /> - 35,000 LBS. <br /> I l � <br /> 3 <br /> 04.19.2024 PERMITSET <br /> 06.05.2024 PERMIT REVISION REV7 <br /> _ I I <br /> I I <br /> CODE KEYNOTES: <br /> I I <br /> 12 Ci FIRE EXTINGUISHER CABINET, <br /> I I <br /> I I <br /> EXIT 2 48" C2 ADA CLEAR SPACE PER ICC/ANSI A117.1 SECTION 305. <br /> EX EXIT <br /> — -- <br /> ALL COUNTERS ARE 34"HIGH PER[CC/ANSI At 17.1 SECTION 902. <br /> I I <br /> ADA CLEAR SPACE FOR REFRIGERATORS/FREEZES PER ANSI A117.1 SECTION 904 <br /> UNOBSTRUCTED TURNING SPACE i © CLEARANCE ERCC/ANSI Al 17A SECTIONPERMITTED TO INCLUDE KNEE AND TOE <br /> 04 <br /> °oe Doe <br /> o 0 <br /> CODE NOTES: <br /> Y o 0 1. MEANS OF EGRESS ILLUMINATION:THE MEANS OF EGRESS(EXIT PATHWAY) <br /> EVo o AND THE EXIT DISCHARGE DOOR SHALL BE ILLUMINATED AT ALL TIMES THE <br /> EV EV EV BUILDING IS OCCUPIED ATAN ILLUMINATION LEVEL NOT LESS THAN 1-FOOT <br /> ® ® ® ® LIGHTING WALKINGNDLE (IOLUX AT THE TI G MUST BE PROVIDED WITH EMERGENCY BATTERY BACK-UP PER IBC <br /> 1008.3. <br /> 2. EGRESS LIGHTING SHALL BE DESIGNED BY LICENSED ELECTRICAL <br /> ENGINEER ACCORDING TO APPLICABLE CODES/ORDINANCES IN JURISDICTION. JURISDI-ON-P <br /> SHALLENGINEER MAY REFERENCE THIS CODE SUMMARY SHEET.HOWEVER,IT OVERALL FLOOR <br /> SHALL REMAIN THE SOLE RESPONSIBILITY OF THE ENGINEER TO COMPLETE A <br /> SCOPE OF WORK ADDRESSING ALL EGRESS LIGHTING I.E.;ROOMS, <br /> $ SPECIALIZED SPACES,PATHWAYS,ETC.PER THE AFOREMENTIONED CODES, PLAN, EXIT PLAN & <br /> FINAL EGRESS LIGHTING DESIGN SUBJECT TO BUILDING OFFICIAL DISCRETION. <br /> 3. EGRESS DOORS WITH CARD READERS SHALL BE FAIL-SAFE TO REMAIN C 0 D E SUMMARY <br /> UNLOCKED DURING AN EVENTIEMERGENCY PER IBC 1010.1.9. <br /> ' 4. NON-EGRESS DOOR WITH CARD READERS SHALL BE FAIL SECURE TO REMAIN <br /> LOCKED DURING AN EVENTIEMERGENCY.DOOR CAN STILL BE OPENED WITH A <br /> OVRALL FLOOR PLAN & EXIT PLAN KEY DURING SUCH EVENT/EMERGENCY. I C�`J. 1 <br /> 3 „ 5. FIRE EXTINGUISHERS MUST BE WITHIN A 75'MAXIMUM TRAVEL DISTANCE OF <br /> SCALE:1/16"=1'-O" ANY LOCATION. <br /> ©2024,JPC Ardii,egs.LLC <br />