Laserfiche WebLink
22014830 <br /> REGISTERED <br /> aIs �1 11 I ARCHITECT <br /> AUG 01 2024 ELIZABETH LAY <br /> STATEOFWAS INGTON <br /> CITY OF EVERET"T <br /> LITTLE PANDAS PLAY CAFE Permit Services <br /> TENANT IMPROVEMENT J W <br /> J 3 <br /> Z <br /> m � <br /> w yyJJ� <br /> WI <br /> GENERAL NOTES SHEET INDEX PROJECT TEAM PROJECT DESCRIPTION <br /> wa W a <br /> OWNER <br /> 1.THESE GENERAL NOTES PERTAIN TO WORK DESCRIBED ON ALL CONTRACT DOCUMENTS. PEARSON FAMILY INVESTMENTS PLAY CAFE TENANT IMPROVEMENT o w _ <br /> TENANT:KISHAN AND AZKA MISTRY(LITTLE PANDAS PLAY CAFE) ., <br /> 2.THE CONTRACT DOCUMENTS CONSIST OF THE OWNER CONTRACTOR AGREEMENT,THE CONDITIONS OF CONTRACT PROJECT ADDRESS:210 SW EVERETT MALL WAY,EVERETT,WA 98204 i 8 <br /> (GENERAL,SUPPLEMENTARY,AND OTHER CONDITIONS),THE DRAWINGS,THE SPECIFICATIONS,AND ALL ADDENDA ISSUED w <br /> PRIOR TO AND ALL MODIFICATIONS ISSUED AFTER EXECUTION OF THE CONTRACT. ARCHITECTURAL GENERAL CONTRACTOR ay v T8 <br /> 3.CLAY DESIGN,LLC IS THE AUTHOR OF THESE PLANS AND CLAIMS A COPYRIGHT IN THESE PLANS AND THE DESIGNS s m <br /> CONTAINED IN THESE PLANS.THIS CLAIM IS MADE UNDER TITLE 17 OF THE UNITED STATES CODE AND ALL APPLICABLE A0.2 CODE ANALYSIS/EXITING PLAN JBC GENERAL CONSTRUCTION P:(206)-355.6039 " <br /> TREATIES AND FOREIGN LAWS.THESE COPYRIGHTED DRAWING FILES ARE TO BE USED FOR REFERENCE ONLY.CLAY DESIGN, A1.1 SITE PLAN 2319 S 126TH ST PROPERTY INFORMATION 0 <br /> LLC WILL TAKE NO RESPONSIBILITY FOR ANY CHANGES MADE TO THESE DOCUMENTS BY ANOTHER PARTYAND NO LICENSE IS A2.0 DEMOLITION PLAN SEATTLE,WA 98146 IVAN@JBCCONSTRUCT.COM c0i¢ LL � <br /> GIVEN FOR TRANSFER OF THESE COPYRIGHTS TO ANOTHER PARTY. A2.1 FLOOR PLAN ADDRESS 210 SW EVERETT MALL WAY,EVERETT WA 98204 <br /> 4.THE WORK COMPRISES THE COMPLETED CONSTRUCTION REQUIRED BY-HE CONTRACT DOCUMENTS AND INCLUDES ALL A3.1 ELEVATIONS ARCHITECTURAL <br /> PARCEL 28042400102700 o co a f w = 5 <br /> LABOR NECESSARY TO PRODUCE SUCH CONSTRUCTION,AND ALL MATERIALS AND EQUIPMENT INCORPORATED OR TO BE - - CLAY DESIGN,LLC. P:(208)-660-0890 Z <br /> INCORPORATED IN SUCH CONSTRUCTION. 2911 112 HEWITT AVE,SUITE 5, - SIZE 32,234 SF1.74 AC" z a g c <br /> EVERETT,WA 98201 ELIZABETH CLAYDESIGNLLC.ONMICROSOFT.COM c <br /> 5.SHOP DRAWINGS,PRODUCT DATA AND SAMPLES ARE NOT A PART OF THE CONTRACT DOCUMENTS.THE ARCHITECT WILL 4 w r�-5 m a i <br /> REVIEW THEM,BUT ONLY FOR CONFORMANCE WITH THE DESIGN CONCEPT OF THE WORK AND WITH THE INFORMATION GIVEN 13 h J <br /> IN THE CONTRACT DOCUMENTS.THE CONTRACTOR SHALL NOT BE RELIEVED OF RESPONSIBILITY FOR ANY DEVIATION FROM 20NE ZONE B w w <c a< 'fit <br /> o:� . � io We S <br /> THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE ARCHITECTS REVIEW OF SHOP DRAWINGS,PRODUCT DATA OR 9 �Roo a <br /> SAMPLES. -. `ti <br /> _ J <br /> 6.THE CONTRACTOR SHALL CAREFULLY STUDYAND COMPARE THE CONTRACT DOCUMENTS AND SHALL AT ONCE REPORT TO Additional Permits Are Required pj Z THE ARCHITECTANY ERROR,INCONSISTENCY OR OMISSIONS HE MAY DISCOVER.THE CONTRACTOR SHALL PERFORM NO w <br /> PORTION OF THE WORK ATANY TIME WITHOUT CONTRACT DOCUMENTS OR,WHERE REQUIRED,APPROVED SHOP DRAWINGS, For Tt11S Project To Include: $ v v g E <br /> PRODUCT DATA OR SAMPLES FOR SUCH PORTION OF THE WORK. w F v <br /> Plumbing ®Sprinkler r o E a v a E i a <br /> 7.ALL WORK IS TO CONFORM WITH THE CONTRACT DOCUMENTS.DRAWINGS ARE NOT TO BE SCALED FOR INFORMATION IF Mechanical -'0 a v,o r¢a a g i <br /> UNABLE TO LOCATE DIMENSIONS FOR ANY R anIC81 Fire ITEM OF WORK,CONSULT WITH THE ARCHITECT BEFORE PROCEEDING WITH C� re Alarm <br /> CONSTRUCTION. Electrical �o <br /> 8.IN THE EVENT CERTAIN FEATURES OF THE CONSTRUCTION ARE NOT FULLY SHOWN ON THE CONTRACT DOCUMENTS,THEN a w <br /> THEIR CONSTRUCTION SHALL BE OF THE SAME CHARACTER AS FOR SIMILAR CONDITIONS THAT ARE SHOWN OR CALLED FOR THESE DOCUMENT <br /> ya RD (� <br /> AND SHALL BE REVIEWED BY THE ARCHITECT. MENNSHAVENOTBEENCODES = 19.ALL WORK SHALL BE PERFORMED WITHIN STRICT CONFORMANCE TO THE MINIMUM STANDARDS OF THE CURRENT EDITION APPRO WORED KS THEISSUANCE OF 4 J L U I ppZ I�SUPP PUBLIC MECHANICAL FIRE _ w <br /> OF THE INTERNATIONAL BUILDING CODE AND ALL APPLICABLE NATIONAL,STATE,AND LOCAL LAWS,REGULATIONS AND PLUMBING 1 N ELECTRICAL OR <br /> ORDINANCES. <br /> ERMI7S. C'1 j OF= rRE I.� BASED ON THE FOLLOWING CODES: a CI rY OF VE ETT <br /> 10.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE GENERAL SAFETY DURING CONSTRUCTION,AND ALL WORK SHALL Cc 1'r0 F nE E-1 I' ' BASED <br /> International Building Per It ervi(es <br /> CONFORM TO PERTINENT SAFETY REGULATIONS. �EV IEWED F V P, g Code i o <br /> 2021 International Exist.Bldg Code,Prescriptive 301.3.1 <br /> 11.THE CONTRACTOR SHALL COORDINATE LOCATIONS OF ANY AND ALL MECHANICAL,TELEPHONE,ELECTRICAL,LIGHTING AND 2021 International Mechanical Code rc <br /> PLUMBING INCLUDING ALL PIPING,DUCT WORK AND CONDUIT.COORDINATE ALL REQUIRED CLEARANCES FOR INSTALLATION This dppfOV8l Only applies t0 2021Washington State Energy Code ao <br /> 2021 International Fire Code <br /> AND MAINTENANCE OF THE ABOVE EQUIPMENT. APPROVE the work being performed under 2021 Uniform Plumbing Cade <br /> Office of CommunityPlanning&Economic Develo menl 9 W <br /> , n9 p Permit#�Z`�ds-0 2020 National Electrical Code ~ <br /> 12.THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK USING HIS/HER BEST SKILL AND ATTENTION,HE/SHE SHALL BE PUNNING DEPARTMENT i I 2021 Washington Amendments a SOLELY COORDINATING <br /> ALL <br /> PORTIONS <br /> ALL CONSTRUCTION MEANS,METHODS,TECHNIQUES,SEQUENCES AND PROCEDURES AND FOR and does not recognize any 20171CC/ANSI At17.1 �� U_ <br /> COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. GI�� DATE:; Y existing structure that may not Q <br /> Name_ <br /> 13.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACTS AND OMISSIONS OF HIS/HER EMPLOYEES,SUBCONTRACTORS meet Zoning Code. <L <br /> AND THEIR AGENTS AND EMPLOYEES,AND OTHER PERSONS PERFORMING ANY WORK UNDER A CONTRACT WITH THE <br /> CONTRACTOR. o <br /> DEFERRED SUBMITTALS:ELECTRICAL,PLUMBING <br /> 14.THE CONTRACTOR SHALL PURSUE WORK IN A CONTINUOUS AND DILIGENT MANNER TO INSURE TIMELY COMPLETION OF THE PROJECT. SYMBOL LIST OCCUPANCY GROUP A-2 ^ <br /> 15.THE CONTRACTOR AT ALL TIMES SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIALS OR I.i <br /> RUBBISH CAUSED BY HISMER OPERATIONS.AT THE COMPLETION OF THE WORK,HE/SHE SHALL REMOVE ALL HIS/HER.WASTE FLOOR AREA 2,153 S.F. <br /> NORTH ARROW WOOD FRAMING <br /> MATERIALS AND RUBBISH FROM AND ABOUT THE PROJECT AS WELL AS ALL HISMER TOOLS,CONSTRUCTION EQUIPMENT, /NORTH c2 '^ <br /> (THROUGH MEMBER) ASPHALT FULLY SPRINKLERED YES Ee vJ � <br /> MACHINERY,AND SURPLUS MATERIALS. WOOD FRAMING OVERALL OCCUPANT LOAD 45 air Q > <br /> 16.THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE LOCATION AND/OR PROTECTION OF ALL EXISTING AND PROPOSED (INTERRUPTED MEMBER) BATT INSULATION a W <br /> PROPERTY CONSTRUCTION TYPE VB z m >+PIPING,UTILITIES,STRUCTURES,ADJACENT STREETS,AND IMPROVEMENTS DURING THE PERIOD OF CONSTRUCTION.. a m <br /> F.F. CORNER {,Or_On CEILING HEIGHT BRICK Z <br /> 17.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS,THE CONTRACTOR SHALL PROVIDE AND PAY FOR ALL 0, 0„ SPOT ELEVATION ❑z <br /> 12 <br /> LABOR,MATERIAL,EQUIPMENT,TOOLS,CONSTRUCTION EQUIPMENT,MACHINERY,WATER,HEAT,UTILITIES,TRANSPORTATION, <br /> J�x���7 Y <br /> AND OTHER FACILITIES AND SERVICES NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. �6,6bCy CMU BLOCK <br /> LEVEL ELEVA w o <br /> _ J� TION 3 r- ROOF SLOPE <br /> 18.WHERE CONFLICTS OCCUR,COORDINATE THE LAYOUT AND EXACT LOCATION OF ALL PARTITIONS,DOORS,TELEPHONES 1/2" ROOF SLOPE PLAN 77 0 <br /> AND ELECTRICAL/COMMUNICATION OUTLETS AND SWITCHES WITH ARCHITECT IN THE FIELD BEFORE PROCEEDING WITH <br /> SLOPE CONCRETE W i <br /> CONSTRUCTION. J W <br /> 2 BUILDING SECTION 3-12 DOOR SYMBOL - - E.I.F.S. <br /> 19.WHERE CONFLICT IS ENCOUNTERED BETWEEN THE CONTRACT DOCUMENTS THAT WILL MATERIALLY AFFECT THE QUALITY A9.1 CUT y <br /> OR EXTENT OF THE WORK,SUCH CONFLICT SHALL BE RESOLVED TO THE SATISFACTION OF THE ARCHITECT BEFORE THE e WINDOW SYMBOL GRADE/EARTH <br /> AFFECTED ITEMS AND/OR MATERIALS ARE PURCHASED,FABRICATED AND/OR INSTALLED. 12 N <br /> 20.WHERE PRE MANUFACTURED OR PREFABRICATED ITEMS AND/OR MATERIALS ARE TO BE INSTALLED-THE CONTRACTOR A9.1 WALL SECTION CUT 12 ACCESSORY SYMBOL GRAVEL VICINITY MAP J <br /> SHALL VERIFY ROUGH OR FINISHED DIMENSIONS IN THE FIELD PRIOR TO PURCHASE OR FABRICATION. <br /> 72 PROPOSED <r`• ''.-a ''T; GYPSUM BOARD - PROJECT LOCATION <br /> 21.THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS TO BE FREE FROM DEFECTS FOR A MINIMUM OF ONE DETAIL CALLOUT CONTOUR LINE <br /> YEAR FROM DATE OF FINAL ACCEPTANCE,AND PROMPTLY REMEDY SUCH DEFECTS AND ANY SUBSEQUENT DAMAGE CAUSED A9.1 72 <br /> BY THE DEFECTS OR REPAIR THEREOF,AT NO EXPENSE TO THE OWNER.GUARANTEE PERIODS OF GREATER THAN ONE YEAR EXISTING ' GYPSUM SHEATHING <br /> MAY BE REQUIRED AND CONTAINED WITHIN THE CONTRACT DOCUMENTS. 1 CONTOUR LINE <br /> PROPERTYLINE ORIENTED STRAND <br /> 22.UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL SECURE AND PAY FOR THE � ur <br /> BUILDING PERMrr AND FOR ALL OTHER PERMITS AND GOVERNMENTAL FEES,LICENSES AND INSPECTIONS NECESSARY FOR THE 2 A8.1 4 ELEVATION BUBBLE BOARD Z <br /> PROPER EXECUTION AND COMPLETION OF THE WORK. ^� MATCH LINE PLYWOOD SHEATHING O <br /> 3 B �r y <br /> 23.WHERE ANY ITEM AND/OR MATERIAL F INDICATED IN THE CONTRACT DOCUMENTS,AND NOT NECESSARILY DETAILED RI NAME ----- CENTERLINE RIGID INSULATION EACH SPECIFIC CASE,BUT IS REQUIRED FOR IL COMPLETE AND PROFESSIONAL INSTALLATION-SUCH ITEM AND/OR MATERIAL ROOM NAME& <br /> SHALL BE PROVIDED AS IF SHOWN AND DETAILED IN FULL.PROVIDE MEANS TO FURNISH AND INSTALL. NUMBER SAND/PLASTER <br /> / U <br /> �H H- PHONE LINE ;. ':'.'.�'`.:`i:;, <br /> REVISION CLOUD& h _J a w <br /> NUMBER G-G- GAS LINE 7/%�i7�%�////// STEEL 0 o y <br /> L Z o <br /> CHANGE IN FLOOR ELECTRICAL LINE STONE 0 r <br /> TIL, E�CARPiT MATERIAL E-E �� �LL�1I W <br /> n -X-X- FENCE LINE IL[.fV1J1WL111(JIY1I11L TECTUM vL♦ } a <br /> SS-SS- SANITARYSEWER ® WOOD FINISH */i CC U ri <br /> + <br /> GRID LINES TV-TV- TELEVISION LINE G m fV Z <br /> ZGLASS <br /> -W-W- WATERLINE a <br />