Laserfiche WebLink
a0or <br /> N Q1 pap c <br /> GENERAL NOTES N #10 <br /> �0D <br /> �g <br /> 1. BATTERY CALCULATIONS FROM THE FULL EXISTING N Q do a <br /> BUILDING HAVE BEEN ADDED FOR REFERENCE ONLY.ALLdo <br /> CIRCUITS THAT HAVE BEEN ADDED OR ALTERED FOR THIS _3 t <br /> T.I.'S SCOPE OF WORK HAVE BEEN OUTLINED IN BOLD W tl c <br /> WITH A'SCOPE OF WORK"TEXT DESIGNATION. e Q O- <br /> pHmeh <br /> UL N <br /> UOta a <br /> O O a <br /> W Z s 3 <br /> LOW VOLTAGE SYSTEMS eY /•� <br /> PANEL PSI(PSN-106)BATTERY CALCULATION / • <br /> (SECONDARY POWER SOURCE REQUIREMENTS) °'°ry omm <br /> PANEL POWER SUPPLY MAX CURRENT=10A TOTAL USED CAPACITY(IN ALARM)=6.691A(66.91%) ""'°""°""""""-1- V <br /> STANDBY CURRENT(AMPS) SECONDARY ALARM CURRENT(AMPS) 19630 40TH AVE WEST <br /> CITY PART NO. DESCRIPTION CURRENTDRAEi TOTAL(A) CURRENTDRAW(A) TOTAL <br /> PANEL COMPONENTS 1 PSN-106 MAIN BOARD PSN-106 MAIN BOARD 6.075 0.075 0.075 0.075 LYNNWOOb,WA 98036 <br /> CIRCUIT SYMBOL OTY PART NO DESCRIPTION CURRENTDRAW(A) TOTAL(A) CURRENTDRAW(A) TOTAL(A) C425�-774-9099 <br /> Addressable Relay Module <br /> PS1•AUX1 0 4 AOM-2RF W/FlaahScan,2 Fonn-C 0.018 0.072 0.018 0.072 <br /> Dry Contacts <br /> R. Horn Strobe,Ceiling,White F <br /> Lp� 2 CHS-24W Soled <br /> 0 0.143 0286 <br /> Horn Strobe Ceiling,White <br /> 2 CHS-24W 75cd 0 0 0.223 OA46 <br /> PS1-NAC1 W� 3 CS-24W Strobe,Ceiling,White 15cd 0 0 0.12 0.36 <br /> M 1 CS-24W Strobe,Ceiling,White 75cd 0 0 0.2 02 <br /> Outdoor Horn Strobe,Fixed <br /> �WP 1 HS-24WW-WP 75 Candela,Standard 0 0 0.226 0226 <br /> Enclosure,White 75cd Z <br /> SL Lp� Horn Strobe,Ceiling,White 4 CHS-24W 0 0 0.143 0.572 <br /> 30cd CIRCUIT SETTINGS TOTALS <br /> 2 CS-24W Strobe,Ceiling,White 30cd 0 00.12 0.24 Starting Calculation Voltage: 20.4 Max.Voltage Drop: 1.97 <br /> PSi•NAC2 PSI NAC2 LUMP SUM REPORT Min.Operational Voltage: 16 End Of Line Voltage: 18.43 <br /> Outdoor Hom Strobe,Fixed Max.Circuit Current(A): 3 Voltage Drop Percent: 9.66% <br /> Enclosure,Whhiteite 7 755cd <br /> 4 HS-24WW-VIP 75 Candela, M 0 0 0.226 0.904 Wire Resistance(MFI): 3.07 Total Circuit Current(A): 1.716 <br /> HornStrobe,Ceiling,White Circuit Wiring Properties:V' shie 1412 FPLPIR(NAC)14 AWG,2 Cond.Solid Copper FPLPIR Analog Unlded Total Circuit Length(Ft) 187 Spare Current(A): 1.284 <br /> 1 CHS-24W 15od 0 0 0.143 0.143 Distance measured using drawn segment lengths With 10.00%additional length calculated Total Circuit Resistance(0): 1.148313 Spare Current(A)Percent: 42.80% <br /> Horn Strobe,Ceiling,White Symbol Part No. Description Qty. Device Current(A) Total Current(A) <br /> 1 CHS-24W 30� 0 0 0.143 0.143 w <br /> /I CS24W Strobe,Ceiling,White 30cd 2 0.12 10.24 0 <br /> PSI-NAC3 Horn Strobe,Ceiling,White 1. <br /> 2 CHS-24W 75cd 0 0 0.223 0.446 DEVICE TOTALS CHS-24W Hom Strobe,30od ng,White 4 0.143 0.572 <br /> y� 1 CS-24W Strobe,Ceiling,White 15cd 0 0 0.12 0.12 Outdoor Horn Strobe,Fixed <br /> 2 CS-24W Strobe,Ceiling,White 75cd 0 0 0.2 0.4 WP HS-24WW-WP 75 Candela,Standard 4 0.226 Ill <br /> Enclosure,White 75cd <br /> Horn Strobe,Ceiling,White Calculation Methods: <br /> 2 CHS-24W 0 0 00.23 0.446 PS7•NAC4 75cd Total Resistance(0)=Wire Resistance(Ol x 2 x Total Cimuit Length IN) <br /> 4 CS-24W Strobe,Ceiling,White 75cd 0 0 0.2 0.6Total Voltage Drop=Total Resistance(0)x Total Circuit Cunent(A) <br /> Hom Strobe,Ceiling,White1 CHS-24W 15� 0 0 0.143 0.143 CIRCUIT SETTINGS TOTALS <br /> PS1•NAC5 Starting Calculation Voltage: 20.4 Max.Voltage Drop: 1A6 <br /> 3 CHS-24W Horn Strob,CCeeiling,White 0 0 0.223 0.669 AiL <br /> STEIKPSI Ill LUMP SUM REPORT Min.Operational Voltage: i6 Entl Of Line Voltage: 18.94Max.Circuit Current(A): 3 Voltage Drop Percent: 7.13% o�,,LornaTOTAL STANDBY(A) 0.147 TOTAL ALARM(A) 6.691 Wire Resistance((LIeFQ: 3.07 Total Circuit Cunent(A): 1.152 nxr.B9a7MREQUIRED STANDBY TIME=24 HOURS ••=µ��SCOPE OF WORK REQUIRED ALARM TIME=5 MINUTES Circuit Wiring Properties:V'1412 FPLPIR(NAG)14 AWG,2 Cond.Solid Copper FPLP/R Analog Unshielded Total Circuit Length(Ft): 189 Spare Current(A): 1.748 <br /> SECONDARY STANDBY LOAD(A) 0.147 24 3.53 Distance measured using drawn segment lengths With 10.00%additional length calculated Total Circuit Resistance(0): 1.162178 Spare Current(A)Pattenk 58.27% <br /> SECONDARY ALARM LOAD(A) 6.691 0.08 0.56 Symbol Part No. Description Qty. Device Current(A) Total Current(A) <br /> STANDBY AND ALARM SUBTOTAL(AMP HOURS) 4.09 GS-24W Strobe,Ceiling,White 75cd 1 0.12 0.12 ■ <br /> DERATING FACTOR 12 Horn Strobe,Ceiling,White H <br /> SECONDARY LOAD REQUIREMENTS(AMP HOURS) 4.9 CHS-24W SOW 1 0.143 0.143 0- <br /> PROVIDE(2)12V 7AH BATTERIES DEVICE TOTALS Horn Strobe,Ceiling,White ■ <br /> 'BATTERY BOX SIZE CAPACITY NOT SPECIFIED.REFER TO MANUFACTURER DOCUMENTATION. ��✓ CHS-24W 15cd 1 0.143 0.143 H <br /> CS-24W Strobe,Ceiling,White 75cd 2 0.2 0.4 O O <br /> Horn Strobe,Ceiling,White 0 <br /> 2 0.223 0.446 <br /> CIRCUIT SETTINGS TOTALS CHS-24W 75cd N <br /> Stating Calculation Voltage: 20.4 Max.Voltage Drop: 0.74 Calculation Methods; <br /> PSI AUX1 LUMP SUM REPORT Min.Operational Voltage: 16 End Of Line Voltage: 20.26 Total Resistance(0)=Wire Resistance(Ol x 2 x Total Circuit Length(Ft) <br /> Max.Circuit Ctl(A): 3 Voltage Drop Percent: 0.70% ITotal Voltage Drop=Total Resistance(0)x Total Circuit Current(A) 0� V <br /> W re Resistance((VkFt): 3.07 Total Circuit Current(A): 0.072 LU1611 yt/ J <br /> Circuit Wiring Properties:'P'1412 FPLPIR(AUX)14 AWG,2 Cord.Solid Copper FPLPIR UnShiekled Total Circuit Length(Ft): 324 Spare Current(A): 2.g2g CIRCUIT SETTINGS TOTALS Q <br /> Distance measured using drawn segment lengths with 10.00%additional length calculated Total Circuit Resistance(0): 1.9879 Spare Current(A)Percent 97.60% Starting Calculation Voltage: 20.4 Max.Voltage Drop: 1.71 <br /> No. Min <br /> Symbol Part Description Qty. IDEA.Current(A) Total Current(A) PS1 NAC4 LUMP SUM REPORT Operational Voltage: 16 End Of Line Voltage: 18.69 Q <br /> AddressaS Relay Module Mu.Circuit Current 3 Voltage Drop Percent: 8.38%DEVICE TOTALS AOM-2RF WI Flesh can,2 Formi 4 0.018 0.072 O <br /> Wire Resistance(QAeFQ: 3.07 Total Circuit Current A): 1.248 0 <br /> Dry Contacts Circuit Wiring Properties:V 1412 FPLPIR(NAC)14 AWG,2 Cond.Solid Copper FPLPIR Analog Unshielded Total Circuit Length(Ft): 224 Spare Current(A): 1.754 J U <br /> Calculation Methods: Distance measured using drawn segment lengths With 10.00%additional length calculated Total Circuit Resistance(0): 1.372599 Spare Current(A)Percent: 58.47% J <br /> Total Resistance(0)=Wine Resistance(OIFt)x 2 x Total Circuit Length(Ft) S mbol Part No. Description Qty. Device current(A) Total Current(A)yl.1 <br /> Total Voltage Drop=Total Resistance(0)x Total Circuit Current(A) c <br /> DEVICE TOTALS CS-24W Strobe,Ceiling,White 75cd 4 0.2 0.8 C <br /> L6 0 <br /> CIRCUIT SETTINGS TOTALS � CHS14W Hom Strobe,Ceiling,White 2 0 �1 z <br /> Starting Calculation Voltage: 20.4 Max.Voltage Drop: 1.79 75cd .223 0.446 1 <br /> PSI NAC1 LUMP SUM REPORT Min,Operational Voltage: 16 End Of Line Voltage: 18.61 Calculation Methods; �IrrN <br /> Max.Circun Cuumnl(A), 3 Voltage Drop Percent: 8.78% Total Resistance(0)=Wire Resistance(Q/FQ x 2 x Total Circuit Length(Ft) 1 Ly <br /> Wine Resistance(OIkFQ: 3.07 Total Circuit Current(A): 1.518 Total Voltage Drop=Total Resistance(0)x Total Circuit Current(A) Uj LLI W LIJ <br /> Circuit Wring Properties:V 1412 FPLPIR(NAC)14 AWG,2 Cond.Solid Capper FPLPIR Analog Unshielded Total Circuit Length(Ft): 192 Spare Current(A): 1.482 >Distance measured using drawn segment lengths with 10.00%additional length calculated Total Circuit Resistance(0): 1.180454 Spam Current(A)Percent 49.40% CIRCUIT SETTINGS TOTALS w F- <br /> symbol Part No. Description Qty. Device Current(A) Total Current(A) Starting Calculation Voltage: 20.4 Max.Voltage Drop: 1.17 III <br /> CS-24W Strobe,Ceiling,White 15cd 3 0.12 0.36 PSI NAGS LUMP SUM REPORT Min.Operational Voltage: 16 End Of Line Voltage: 19.23 m <br /> Max.Circuit Current(A): 3 Voltage Drop TrentPercent: 5.8% N e <br /> Horn Strobe,Ceiling,White Win:Resistance QAeFt: 3.07 Total Circuit Curren[A: 0.872 C <br /> CHS24W 30cd 2 0.143 0.186 ( ) () Q Ly <br /> Circuit Wiring Properties:V 1412 FPLPIR(NAC)14 AWG,2 Conti.Solid Copper FPLPIR Analog Unshielded Total Circuit Length(Ft): 235 Spare Current(A): 2.166 (Y� <br /> DEVICE TOTALS CS-24W Strobe,Ceiling,White 75cd 1 0.2 0.2 Distance measured using drawn segment lengths With 10.00%additional length calculated Total Circuit Resistance(Ol 1.445033 Spare Current(A)Percent: 72.93% a- <br /> LU <br /> �7. Hom Strobe,Ceiling,White Symbol Pail No. Description Qty. Device Current(A) Total Current(A) J <br /> gl CHS24W 2 0.223 0.446 Q <br /> 75cd Horn strobe,Ceiling,White F W <br /> CHS-24W 1 0.143 0.143 <br /> Outdoor Hom Strobe,Fixed DEVICE TOTALS 75cd <br /> WP HS24WW-WP 75 Candela,Standard 1 0.226 0.226 SZ Horn Strobe,Ceiling,White w III <br /> CHS-24W 3 0.223 0.889 w <br /> Enclosure,White 75cd 75cd = LL <br /> Calculation Methods: Calculation Methods: r^ <br /> Total Resistance(Q)=W re Resistance((lll't)x 2 x Total Circuit Length(Ft) Total Resistance(0)=Wire Resistance(Q/Ft)x 2 x Total Circuit Length(Ft) <br /> Total Voltage Drop=Total Resistance(0)x Total Circuit Current(A) Total Voltage Drop=Total Resistance(0)x Total Circuit Current(A) JDRAWN BY: JA Ad <br /> �( <br /> CHECKED BY: Adrilan M.Stei-` <br /> PLOTDATe 9/15/23 <br /> PROIECr NUMBER: 23-124 <br /> A SFIRE ALARM BATTERY AND CIRCUIT CALCULATIONS - PS1 <br /> =NOT TO SCALE FA2 ,3 <br /> DRAWING ONLY TO SCALE IF PLOTTED AT 24"X 36' SHEET NUMBER: <br />