Permit#: K2309-020 <br /> Site Address: 1302 SE Everett Mall Way Suite 102 L ow <br /> Applicant: Dion Smith EVERETT <br /> Application Date:Relocation <br /> Everett Fire Dept.Permit Review tl I C I N I T Y P L A N <br /> Description: Relocation of 112 heads and adding 10 Status:Approved <br /> pendant heads Reviewed By:KBrown <br /> 09/26/2023 11:09:49 <br /> Review Status: 1st Review by City&Peer Reviewers AM TRADER JOE'S #139 <br /> Review Dale: 09/26/2023 <br /> 1302 SE EVERETT MALL WAY <br /> APPROVED SUITE 102 c <br /> PUBLIC WORKS DEPARTMENT EVERETT, WA 92802 <br /> BY: 0EVERETVERET <br /> Teleran- <br /> DATE: <br /> CITE:F T REVIEWED FOR PERMIT <br /> r r t <br /> I r s __ IV <br /> 4M <br /> l� II <br /> i!V on <br /> UPRIGHT <br /> TRUSS GIRDER ROOF JOISTS SPRINKLER ;t",/ ir •^ ,'r y <br /> j;Lill <br /> U.L. LISTED VICTAULIC AH-2 Flexible Sprinkler Drop O <br /> DROP FROM - <br /> OVERHEAD SALES 'I <br /> PIPING <br /> l <br /> Y: <br /> NOTE:COORDINATE EXACT LOCATION OF SPRINKLERS BRANCHLIKE AND NEW 1"AR MOVER <br /> AT COOLERS/FREEZERS WITH LIGHTS,EVAPORATORS MECHANICAL TEE WHERE REQUIRED <br /> LIGHTS AND OTHER OBSTRUCRONS. NOTE THAT FINAL ® _ <br /> LIGHT AND EVAPORATOR LOCATIONS MAY DIFFER <br /> CONDENSER FROM THOSE SHOWN ON PLANS Multi-Port Bracket <br /> DRY CONCEALED Adjustable Hub <br /> PENDENT SPRINKLER / <br /> GROCERY <br /> STORAGE <br /> FREEZER/COOLER <br /> 6 FREEZER SECTION Sprinkler Head SCOPE OF WORK BY BURNS FIRE SYSTEMS <br /> NO SCALE ROOM OCCUPANCY DESIGNATIONS <br /> THIS SUBMITTAL IS FOR MODIFYING EXISTING SYSTEM FOR SPRINKLER PROTECTION TO CONFORM ALL AREAS ARE ORDINARY HAZARD GROUP 2 OCCUPANCIES UNLESS NOTED OTHERWISE <br /> TO TRADER JOE'S TENANT IMPROVEMENT- <br /> EX I STING PIPING IS TO REMAIN.WORK CONSISTS OF REPLACING PENDANT HEADS WITH NEW L LIGHT HAZARD Light hazard occupancies shall be defined as occupancies or portions of other occupancies <br /> PENDANT HEADS SUPPLIED FROM EXISTING PIPE OUTLETS OR NEW CONNECTIONS TO EXISTING PIPE.BUILDING IS PRIMARILY RETAIL SALES WITH RESTROOMS,STOCK ROOM,AND OTHER Where the quantity and/or combustibility y of contents is low and fires With relative) low rates <br /> SUPPORT AREAS.BURNS FIRE PROTECTION SYSTEMS TO START AT EXISTING RISER MANIFOLD, Of heat release are expected <br /> OPTION "A" INSTALLATION PROCEDURE OPTION "B" INSTALLATION PROCEDURE NSIDEOF THE BUILDING. H ORDINARY HAZARD ordinary hazard (Group 1) occupancies shall be defined as occupancies or portions <br /> of other occupancies where combustibility is low, quantity of combustibles is moderate, <br /> stockpiles of combustibles do not exceed 8 ft (2.4 an, and fires with moderate rates of heat <br /> 1. CORE DRILL 2 1/2"DIAMETER HOLE IN THE FREEZER/COOLER INSULATED 1. CORE DRILL 2 1/2"DIAMETER HOLE IN THE FREEZER/COOLER INSULATED GENERAL NOTES: ^ release are expected. <br /> CEILING PANEL. LOCATE HOLE AND REQUIRED SPRINKLER PROTECTION CEILING PANEL FROM BELOW. LOCATE HOLE AND REQUIRED SPRINKLER 1. DESIGN AND INSTALLATION TO CONFORM WITH NFPA #13 2016 AND THE CITY OF EVERETT. �/k4\� Ordinary hazard (Group 2 occupancies Shall be defined OS occupancies CieS Or portions <br /> IN ACCORDANCE'NTH NFPA 13 OBSTRUCTION CRITERIA(SSP TYPE PROTECTION IN ACCORDANCE NTH NFPA 13 OBSTRUCTION CRITERIA(SSP 2. ALL MATERIALS TO BE NEW AND UT OR FM LISTED. ZH ORDINARY HAZARD y ( P ) P P P <br /> SPRINKLERS). MAINTAIN 6"CLEARANCE FROM COOLER SEAMS. TYPE SPRINKLERS). MAINTAIN 6"CLEARANCE FROM COOLER SEAMS. 3. PROTECTION OF SPRINKLER FROM PAINT BY OTHERS. of other occupancies where the quantity and combustibility of contents are moderate t0 high, <br /> 4. ALL THREADED PIPE To BE SCHEDULE 40 BLACK STEEL PIPE. where stockpiles of contents with moderate rates of heat release do not exceed 12 ft (3.66 m) <br /> 2. INSTALL DRY PENDENT SPRINKLER PER MANUFACTURERS INSTALLATION ALL 1%" TO 4" PIPE JOINED WITH GROOVED FITTINGS DYNAFLOW BLACK STEEL PIPE WITH <br /> REQUIREMENTS. 2. INSTALL TYCO DRY PENDENT SPRINKLER PER MANUFACTURERS INSTALLATION W 5.ELDED OUTLETS. and Stockpiles of contents with high rates of heat release do not exceed 8 ft (2.4 m). <br /> REQUIREMENTS. INSERT BOOT PRIOR TO MAKE-UP WITH PIPING. 6. FITTINGS TO BE BLACK CAST IRON OR PAINTED GROOVED. <br /> 3. COMPLETELY FILL ANNULAR CEILING OPENING BETWEEN THE ESCUTCHEON AND 3. COMPLETELY SEAL INTERFACE BETWEEN BOOT FLANGE AND TOP OF 7. ALL PIPE ELEVATIONS ARE TAKEN FROM CENTER LINE OF PIPE AND ARE AS MARKED ON THE HYDRAULIC CALCULATION DESIGN PARAMETERS <br /> TOP OF CEILING PANEL WITH OPEN-CELL POLYETHYLENE FOAM BACKER ROD. DRAWINGS. <br /> EXPANDED FOAM IS NOT PERMITTED. FREEZER/COOLER PANEL WITH ADHESIVE PROVIDED WITH BOOT IN 8. SYSTEM IS DESIGN TO DELIVER PER THE NOTES ON THE PLAN. NFPA#13 2016- <br /> ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 9. ALL SWAY BRACING TO BE 1" SCH40 PIPE FASTENED PER APPROPRIATE DETAIL. <br /> 4. INJECT DOW CORNING 739 PLASTIC ADHESIVE SEALANT INTO AND AROUND 10. ALL GROOVED COUPLING ARE TO BE RIGID UNLESS NOTED OTHERWISE. HYDRAULIC CALCULATION PREFORMED TO BASE OF RISER.DEMAND REQUIRED FOR <br /> THE TOP OF THE FREEZER/COOLER CEILING CORE OPENING IN ACCORDANCE 4. APPLY STRAP TIES ON BOOT AROUND DRY SPRINKLER BARREL PER 11. FLOW AND TAMPER SWITCHES To BE PROVIDED AND INSTALLED BY BURNS FIRE SYSTEMS. TENANT IMPROVEMENT DOES NOT EXCEED DEMAND REPORTED IN CORE AND SHELL <br /> WITH SEALANT MANUFACTURERS INSTRUCTIONS MANUFACTURERS INSTRUCTIONS. 12. ALL ELECTRICAL WIRING TO BE PERFORMED BY OTHERS. CALCULATIONS DATED 2�8�2023 <br /> 13. ALL FLOW SWITCHES AND TAMPER SWITCHES SHALL BE TAMPERED/MONITORED AS REQUIRED BY <br /> CODE. SALES AREA ORDINARY GRP 2-.20 GPM DENSITY OVER REMOTE 945 SQ.FT.DESIGN AREA <br /> 15-15. THE Q ER IS To PROVIDE MONITORING AS REQUIRED. DESIGN AREA ADJUSTED PER NFPA#13 FOR QUICK RESPONSE HEADS AND 12'MAXIMUM <br /> IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN ADEQUATE HEAT TO PREVENT FREEZING <br /> SUPPLY FROM WET SUPPLY FROM WET WATER IN THE PIPES. CEILING HEIGHT. <br /> PIPE SPRINKLER SYSTEM PIPE SPRINKLER SYSTEM 16. SPRINKLER HEADS ARE TO BE SPACED PER NFPA #13 AND PER THEIR U.L. LISTING. Calculation results for Design Area 1 -Retail Area <br /> 17. ALL PENETRATIONS THIRD RATED WALL SHALL BE FIRECAULKED. This system as shown on company print no dated <br /> 18. THIS ADDITION IS ORDINARY GROUP 2 OCCUPANCY. for Trader Joe.Federal Way at 1302 Everett Mall Way <br /> TEE WITH PLUG TEE WITH PLUG 20.TOTAL NUMBER OF ADDED SPRINKLERS = 122. contract no is designed to discharge at a rate of 0.2 gpm/ft'(L/min/m°)of floor area over <br /> 20. AREA OF TENANT IMPROVEMENT 13,230 SQ.FT. a maximum area of 945 W when supplied with water at a rate of 278.8 opm at 44.4 psi at the base of the riser. <br /> Hose stream allowance of is included in the above. <br /> 1"DRY 1"DRY 2 NYLON STRAP TIES C`�/h,1 D C` Occupancy classification:OH 2 Number of heads flowing:10 <br /> SPRINKLER DROP SPRINKLER DROP (INSTALL OPPOSITE DIRECTIONS) - PIPING SYMBOLS:LJOLJ. Commodity classifcation: System Type: Wet <br /> OPEN CELL Maximum storage height: Maximum velocity: 22.17 fVs <br /> DOW CORNING 739 TYCO RUBBER SEAL Storage arrangement: <br /> POLYETHYLENE PLASTIC ADHESIVE BOOT MODEL DSB-2 ro Approximate Hanger Location <br /> FOAM BACKER ROD ? r Flow from In-Rack sprinklers: 0 gpm pressure Required at Source: 44.4 psi <br /> FREEZER/COOLER FREEZER/COOLER SEALANT PER BOOT w J Approximate Bracing Location Flow from Overhead sprinklers: 278.8 gpm Pressure Available at Source: 52.9 psi <br /> CEILING CEILING MANUFACTURER �' Flow from Inside Hoses: 0 gpm Surplus Pressure at Source: 8.4 psi <br /> Approximate Location of Grooved Coupling <br /> Flow from Outside Hoses: 0 gpm <br /> +0-0 Elevation from Floor to Centerline of Pipe Other fixed flows: oppm <br /> Total flow in system piping: 278.8 gpm <br /> -0 BOJ Elevation down from Joist to Centerline of Pipe Additional flow at/beyond source: 0all <br /> Total of all flows: 278.8 gpm <br /> -0 BOB Elevation down from Beam to Centerline of Pipe <br /> SPRINKLER CUP CONCEALED 200T DRY SPRINKLER CUP CONCEALED 2007 DRY INSTALLATION NOTES <br /> PENDENT SPRINKLER PENDENT SPRINKLER (0-0') Center to Center Dimension of Pipe <br /> COVER PLATE 2k" COVER PLATE 2y" O'-0" Cut Dimension of Pipe Q REMOVE EXISTING PENDANT HEADS.ADD 1"DROP TO 18"ABOVE CEILING <br /> O Hydraulic Reference Point FLEX DROP ARMOVERS TO NEW PENDANT HEAD LOCATIONS <br /> OPTION A OPTION B ADD MECHANICAL TEE CONNECTION TO EXISTING PIPE <br /> O 9 Rise/Drop <br /> - EXISTING AND TO REMAIN U.N.O. <br /> NOTE: CONTRACTOR TO SEAL DRY PENDENT SPRINKLERS AT FREEZER/COOLER USING ONE OF THE OPTIONS ABOVE. NO OTHER SEALANTS ARE PERMITTED. ® Main Sprinkler Riser NEW PIPING INCLUDED IN THIS SUBMITTAL <br /> 4 FREEZER COOLER DRY PENDENT SPRINKLER (NAS) No Automatic Sprinklers ('12)TOTAL RELOCATED <br /> (TUTS) NOT TO SCALE I},`�_ PENDANT HEADS To DE To AND r ouILET <br /> NO SCALE <br /> USED TO SUPPLY NEW PENDANT HEAD <br /> TYPICAL UNLESS NOTED OTHERWISE <br /> ( TOTAL ADDED <br /> NEW PENDANT HEADS SUPPLIED FROM <br /> NEW MECHANICAL TEE <br /> N NOTES REVISIONS SPRINKLER SYMBOLS NOTES AND <br /> ........ DATE DESCRIPTION 9 <br /> WASHINGTON STATE - <br /> SW CNT POSITION FINISH TEMP K NIT SIN MFG. MODEL BFPS, INC T�AD�� Jo]E s T. I. DETAILS <br /> CERTIFICATE OF COMPETENCY / 6 SIDE CHROME 155 11.20 1' TY...S TYCO DS3 EXISTING HEADS <br /> FIRE PROTECTION SPRINKLER SYSTEMS( 159 PEND CHROME 155 5.60 1/2' TY3231 Tyco TY-FRB EXISTING HEADS PERMIT NO. <br /> w O E David <br /> Vatee o 112 IPEND CHROME 1155 1 5.60 11/2- ITY3231 Tyco TY-FRB NEW HEADS P.O.B. 1110 1302 EVERETT MALL WAY CONTRACT NO. <br /> 2605-0898-C Lave13 (W 10 IPEND CHROME 1155 1 5.60 1' TY3235 Tyco IDS-1 NEW HEADS <br /> •Burns Fire Protection Systems,Inc. ; <br /> DYATES <br /> B Fire teu GRANITE FALLS, WA EVERETT, WA DRAWN <br /> APPROVAL <br /> clrY of EVERETT <br /> / 9 20 Fsplrcs: ; <br /> 425-388-0124 SCALE BY <br /> 3 Signal re Dale 12B1123 • SCALE 1/8" = 1'-0" <br /> ................................ <br /> DESIGN QUESTIONS 360-580-1062 CONTRACTOR: <br /> KsED 9/2o/2a <br /> T1ED FP 1 <br />