Laserfiche WebLink
Ui Q O.� <br /> Permit#: FA2305-005 N <br /> Site Address: 3301 Seaway Blvd #N 1 <br /> Applicant: Cris Davis W ,p o <br /> Application Date:5/10/2023 crWo H <br /> Description: Adding Devices to Existing Fire System Q m e <br /> Review Status: tat Review by City&Peer Reviewers J V <br /> Review Date: 5/17/2023OUSE <br /> UH <br /> �<Hrna <br /> EVERETT eve•e.r L<tv g <br /> 14 <br /> Everett Fire Dept.Permit Review IV{EVLB LAB WAREH T 1 I <br /> Status:Approved In 0 8 <br /> Reviewed By:(Brown __ O m <br /> 05/17/2023 11:58:12 ro Z v 3 <br /> FIRE ALARM SYSTEM AM Naa <br /> Z W, <br /> 00nN <br /> W Op�pQ� <br /> X�1� <br /> PROJECT INFORMATION DEVICE LEGEND smn st sw - - 3' ♦ <br /> SYMBOL MANUFACTURER PART NO DESCRIPTION CITY W L N W <br /> NAME. EVLB LAB WAREHOUSE T.I. l U I <br /> ADDRESS: SEAWAY WEST BUILDING NAc INTELLIKNIGHT POWER MODULE FOR 5820XL 5A 24VDC Wl Iity Center Byram Healthcare J v O�VV <br /> 0 SILENT KNIGHT 5895XL 1 Hearthstone de at <br /> 3301 SEAWAY BLVD. 5815xL sLc EXPANSION CARD Q Applied Technical Q Merrill C`reek� W ^ <br /> EVERETT,WA 98203 0 QFunko Warehouse 2 Services LL d SILENT KNIGHT SK-PHOTO ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR 67 <br /> f Fri lo Lay Ever <br /> Cintas Uniform Services Q distribution cen <br /> SCOPE OF WORK SYSTEM SENSOR PC2WL 2-WIRE,HORN STROBE,WHITE 21 <br /> •33111 Seaway Blvd, Altasciences Preclinical Estes Ex <br /> INSTALLATION OF NEW FIRE ALARM COMPONENTS IN A TENANT IMPROVEMENT OFFICE xC SYSTEM SENSOR BOWL STROBE,WHITE 5 ®� Everett,WA 98203 &BQanalysis Services <br /> AND WAREHOUSE SPACE.NEW COMPONENTS WILL BE CONNECTED TO A NEW 5895XL A <br /> SILENT KNIGHT POWER SUPPLY WITH ADDED 5815XLEXISTING <br /> SLC EXPANSION CARD.THE NEW SK ! _ m <br /> POWER SUPPLY WILL CONNECT BACK TO THE EXISTING FIRE ALARM CONTROL PANEL VIA FIRE ALARM CABLE AND WIRE LEGEND <br /> eck <br /> RESISTANCE sed 811E Pallet Shelter) <br /> S-BUS. LABEL WIRE TYPE MFR. PART NO. AWG DESCRIPTION Boeing Bldg40-41 i� seaw <br /> �MN -ight&Camera Lab <br /> eya�o <br /> FIRE ALARM CONTRACTOR A SOUTHWIRE 55-46-88-03 16 4.09 2 COND.SOLID COPPER FPLP Q 6 Sanctuary-, NQ <br /> g © �Ce fN M. STEIK <br /> NAME: ELECTRO TECH B ------------------- COMTRAN 38700 14 3.07 2COND.SOLID COPPER FPLR ANALOG UNSHIELDED eonby Pertmelaq Bfl ori20ns nutnonxiny1Of E'g1°`e^09 Te�lh°kbn,­ <br /> Fluke Corpo aT�n Y-. �° <br /> ADDRESS: PO BOX 13889 at Everett fca0on Number:093706 <br /> MILL CREEK,WA 98082 C ------------------------ COMTRAN 38700 14 3.07 2 COND.SOLID COPPER FPLR ANALOG UNSHIELDED a si9naNre: <br /> PHONE: (425)405-0583 D -------------------"- COMTRAN M6W 18 6.7000 4 COND.SOLID COPPER FPLR ANALOG UNSHIELDED Boeing 40-029 m <br /> FAX: (866)798-9241 a„e PMmer•r Ra 9115 <br /> N4Q N79 Boeing40-889 <br /> E, <br /> APPLICABLE CODES AND STANDARDS 75tb St sw <br /> NFPA 72 NATIONAL FIRE ALARM CODE 2019EDITION GENERAL NOTES Boeing40-569 Boeing40-589 F--SnohomishcountyPUD, <br /> INTERNATIONAL BUILDING CODE 2015 EDITION <br /> ! -Operations Center <br /> INTERNATIONAL FIRE CODE 2015 EDITION <br /> NFPA 70 NATIONAL ELECTRICAL CODE 2020 EDITION • ALL FIRE ALARM SYSTEM WORK COMPLETED UNDER THE SCOPE OF THIS FIRE ALARM PLAN REVIEW SHALL BE FIELD VERIFIED BY FIRE INSPECTION <br /> PERSONNEL AND THE FIRE CODE OFFICIAL. N <br /> • VISIBLE NOTIFICATION APPLIANCES SHALL REMAIN ACTIVE(FLASHING)WHEN THE AUTOMATIC AND MANUAL FIRE ALARM SYSTEM IS SILENCED. Z <br /> • FIRE ALARM SYSTEM SHALL TRANSMIT TROUBLE,SUPERVISORY AND FIRE SIGNALS DIRECTLY TO THE COMMUNICATIONS CENTER REMOTE SUPERVISING O <br /> STATION. VICINITY MAP <br /> CIRCUIT LABELING LEGEND MOUNT PULL STATIONS AT42"AT ACTIVATOR WITHIN 5'OF LATCH SIDE OF EXIT DOORS <br /> • MOUNT AUDIO VISUAL DEVICES AT 80"ABOVE FLOOR LEVEL <br /> • A DEDICATED 120VAC,20A BRANCH CIRCUIT BREAKER SHALL BE PROVIDED,MARKED IN RED,LOCK-ON PROVISION AND IDENTIFIED AS"FIRE ALARM <br /> DEVICE IDENTIFIER CIRCUIT CONTROL".THE LOCATION OF THE CIRCUIT BREAKER WILL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. <br /> SLC1•### SLC=SIGNALING LINE CIRCUIT <br /> NAC=NOTIFICATION APPLIANCE CIRCUIT <br /> CIRCUIT IDENTIFIER <br /> SHEET INDEX <br /> ABBREVIATIONS SHEET NO. SHEET DESCRIPTION <br /> FAD.1 TITLE SHEET <br /> .IIIIIIII� IrL <br /> A AMPERE J-BOX JUNCTION BOX FAO.2 OVERALL BUILDING PLAN-FIRE ALARM SYSTEM <br /> AFF ABOVE FINISHED FLOOR kV KILOVOLT <br /> AHU AIR HANDLING UNIT kVA KILOVOLT AMPERE FA1.1 FLOOR PLAN SOUTH-FIRE ALARM SYSTEM <br /> IMMM­ <br /> AL ALUMINIUM kW KILOWATT FIRE ALARM SYSTEM OUTPUTS FA1.2 FLOOR PLAN NORTH-FIRE ALARM SYSTEM Q u II <br /> AMP AMPERE kWh KILOWATT HOUR LU (1, W <br /> AWG AMERICAN WIRE GAUGE MFR MANUFACTURER FACP& C.S. NOTIFICATION FA2.1 FIRE ALARM RISER DIAGRAM&CIRCUIT CALCULATION LU > O <br /> BLDG BUILDING MECH MECHANICAL ANNUNCIATORS MONITORING &CONTROL EQUIPMENT <br /> C CONDUIT MIN MINIMUM <br /> CB CIRCUIT BREAKER (A) NEW -1 I I <br /> CCTV CLOSED CIRCUIT TELEVISION NAC NOTIFICATION APPLIANCE CIRCUIT qCS, 'v W <br /> CKT CIRCUIT NEC NATIONAL ELECTRIC CODE <br /> CLG CEILING NEUT NEUTRAL <br /> CO CONDUITONLY NFPA NATIONAL FIRE PROTECTION ASSOCIATION �./Sp�gLglq �.P F,9 �PK. TYPICAL DEVICE MOUNTING DETAIL IO W <br /> COMM COMMUNICATION NC NORMALLY CLOSED <br /> CU COPPER NIC NOT IN CONTRACT �`gGfB� lC2<<tS Gp F.t, ROOF DECK li <br /> DCV DOUBLE CHECK VALVE NO NUMBER;NORMALLY OPEN O cc 9 f 6 �O `9 G` MOUNTTo <br /> DIA DIAMETER NTS NOT TO SCALE gG�lfe�/.S J C�Yq� lFj����L �O STRUCTURE <br /> DISC DISCONNECT OD OVERHEAD DOOR;OVERALL DIAMETER 6� i�G°C''C c �s `�° BASE HEAD <br /> DIN DOWN PIV POST INDICATOR VALVE �2f.�SG�y.�'L�j,�'� Gq���,p YG J.BOX ABOVE CEILINGJ-Box LU <br /> DO DOOR OPERATOR PNL PANEL sG q� G.o 9,oA OB .p S,S, LU <br /> (E) EXISTING PVC POLYVINYL CHLORIDE(PLASTIC) qt' F'P .1y, `rT Fj,'Y° SUPPORT SUPPORT <br /> BRACKET BRACKET <br /> EF EXHAUSTFAN QTY QUANTITY FIRE ALARM SYSTEM INPUTS qEA EACH PWR POWER `IT, Fs°��'�O2'�O� ��FS'�4��°`�2 PLASTER RING N <br /> ELEC ELECTRIC REQD REQUIRED SYSTEM SMOKE/HEAT DETECTORS �`sE HEAD CEILING I� <br /> ELEV ELEVATOR RH RANGE HOOD SMOKE OR HEAT DETECTOR MANUAL PULL STATION NOTIFICATION <br /> CEILING MOUNT <br /> NonFican O <br /> EMT ELECTRICAL METALLIC TUBING RMC RIGID METALLIC CONDUIT <br /> EOL END OF LINE RESISTOR SF SUPPLY FAN;SQUARE FEET SYSTEM TROUBLE 0 0 1M' <br /> EOLR END OF LINE RESISTOR SLC SIGNALING LINE CIRCUIT BATTERY FAULT 0 0 � 1'1 I I <br /> W EXIST EXISTING SPEC SPECIFICATION ` <br /> F FIXED ST SHUNT TRIP OPEN CIRCUIT/SHORT 0 WALL MOUNT W �/ <br /> FA FIRE ALARM STD STANDARD GROUND FAULT NOTIFICATION APPLIANCE ` J <br /> FAA FIRE ALARM ANNUNCIATOR TEL TELEPHONE <br /> FACP FIRE ALARM CONTROL PANEL TELCO TELEPHONE COMPANY LOSS OF PRIMARY POWER 4 t^ I I <br /> FAPS FIRE ALARM POWER SUPPLY TEMP TEMPORARY ® Q / <br /> FARA FIRE ALARM REMOTE ANNUNCIATOR TS TAMPER SWITCH GENERAL NOTES: <br /> FBO FURNISHED BY OTHERS TYP TYPICAL • REFERENCE NUMBERS ARE SHOWN IN PARENTHESES(1)FOR"NOTES/NOTATIONS"INDICATED BELOW AND IN <br /> FDC FIRE DEPARTMENT CONNECTION UGND UNDERGROUND HEADINGS TO THE RIGHT. FIRE ALARM <br /> FEC FIRE EXTINGUISHER CABINET ILL UNDERWRITERS LABORATORIES • FIRE ALARM SYSTEM DEVICES ARE POINT ADDRESSABLE. CONTROL PANEL <br /> FH FIRE HYDRANT UON UNLESS OTHERWISE NOTED <br /> FPL FIRE POWER LIMITED V VOLT —FIRE ALARM <br /> FPLR FIRE POWER LIMITED RISER VA VOLTAMPERE ANNUNCIATOR H— <br /> FPLP FIRE POWER LIMITED PLENUM VAC VOLTAGE,ALTERNATING CURRENT <br /> FS WATER FLOW SWITCH VDC VOLTAGE,DIRECT CURRENT MANUAL ■ ■ w <br /> FSD FIRE/SMOKE DAMPER VR VANDAL RESISTANT ® PULL W 2 <br /> BB STATION <br /> G GROUND W WATT 000mm <br /> GEC GROUNDING ELECTRODE CONDUCTOR W/ WITH <br /> GEN GENERATOR W/0 WITHOUT ,`a JRC <br /> HT HEATTRACE WP WEATHERPROOF DRAwNer: <br /> IDC INITIATING DEVICE CIRCUIT Z IMPEDANCE Adrian I, <br /> 72' 60' 80" CHECKED BY: Adrian M. Stelk <br /> PLOT DATE: 3/11/2 3 <br /> PROJECT NUMBER: 2 3-025 <br /> I <br /> 1 <br /> FAO , <br /> DRAWING ONLY TO SCALE IF PLOTTED AT 30"X 42"' SHEET NUMBER: <br />