My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3301 SEAWAY BLVD 1 2023 TERRA POWER Plans 2025-04-08
>
Address Records
>
SEAWAY BLVD
>
3301
>
TERRA POWER
>
Plans
>
3301 SEAWAY BLVD 1 2023 TERRA POWER Plans 2025-04-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/8/2025 9:31:41 AM
Creation date
4/8/2025 9:31:22 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
3301
Unit
1
Tenant Name
TERRA POWER
Permit
FA2305-005
Year
2023
Notes
ADDING DEVICES TO EXISTING FIRE SYSTEM
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ui Q O.� <br /> Permit#: FA2305-005 N <br /> Site Address: 3301 Seaway Blvd #N 1 <br /> Applicant: Cris Davis W ,p o <br /> Application Date:5/10/2023 crWo H <br /> Description: Adding Devices to Existing Fire System Q m e <br /> Review Status: tat Review by City&Peer Reviewers J V <br /> Review Date: 5/17/2023OUSE <br /> UH <br /> �<Hrna <br /> EVERETT eve•e.r L<tv g <br /> 14 <br /> Everett Fire Dept.Permit Review IV{EVLB LAB WAREH T 1 I <br /> Status:Approved In 0 8 <br /> Reviewed By:(Brown __ O m <br /> 05/17/2023 11:58:12 ro Z v 3 <br /> FIRE ALARM SYSTEM AM Naa <br /> Z W, <br /> 00nN <br /> W Op�pQ� <br /> X�1� <br /> PROJECT INFORMATION DEVICE LEGEND smn st sw - - 3' ♦ <br /> SYMBOL MANUFACTURER PART NO DESCRIPTION CITY W L N W <br /> NAME. EVLB LAB WAREHOUSE T.I. l U I <br /> ADDRESS: SEAWAY WEST BUILDING NAc INTELLIKNIGHT POWER MODULE FOR 5820XL 5A 24VDC Wl Iity Center Byram Healthcare J v O�VV <br /> 0 SILENT KNIGHT 5895XL 1 Hearthstone de at <br /> 3301 SEAWAY BLVD. 5815xL sLc EXPANSION CARD Q Applied Technical Q Merrill C`reek� W ^ <br /> EVERETT,WA 98203 0 QFunko Warehouse 2 Services LL d SILENT KNIGHT SK-PHOTO ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR 67 <br /> f Fri lo Lay Ever <br /> Cintas Uniform Services Q distribution cen <br /> SCOPE OF WORK SYSTEM SENSOR PC2WL 2-WIRE,HORN STROBE,WHITE 21 <br /> •33111 Seaway Blvd, Altasciences Preclinical Estes Ex <br /> INSTALLATION OF NEW FIRE ALARM COMPONENTS IN A TENANT IMPROVEMENT OFFICE xC SYSTEM SENSOR BOWL STROBE,WHITE 5 ®� Everett,WA 98203 &BQanalysis Services <br /> AND WAREHOUSE SPACE.NEW COMPONENTS WILL BE CONNECTED TO A NEW 5895XL A <br /> SILENT KNIGHT POWER SUPPLY WITH ADDED 5815XLEXISTING <br /> SLC EXPANSION CARD.THE NEW SK ! _ m <br /> POWER SUPPLY WILL CONNECT BACK TO THE EXISTING FIRE ALARM CONTROL PANEL VIA FIRE ALARM CABLE AND WIRE LEGEND <br /> eck <br /> RESISTANCE sed 811E Pallet Shelter) <br /> S-BUS. LABEL WIRE TYPE MFR. PART NO. AWG DESCRIPTION Boeing Bldg40-41 i� seaw <br /> �MN -ight&Camera Lab <br /> eya�o <br /> FIRE ALARM CONTRACTOR A SOUTHWIRE 55-46-88-03 16 4.09 2 COND.SOLID COPPER FPLP Q 6 Sanctuary-, NQ <br /> g © �Ce fN M. STEIK <br /> NAME: ELECTRO TECH B ------------------- COMTRAN 38700 14 3.07 2COND.SOLID COPPER FPLR ANALOG UNSHIELDED eonby Pertmelaq Bfl ori20ns nutnonxiny1Of E'g1°`e^09 Te�lh°kbn, <br /> Fluke Corpo aT�n Y-. �° <br /> ADDRESS: PO BOX 13889 at Everett fca0on Number:093706 <br /> MILL CREEK,WA 98082 C ------------------------ COMTRAN 38700 14 3.07 2 COND.SOLID COPPER FPLR ANALOG UNSHIELDED a si9naNre: <br /> PHONE: (425)405-0583 D -------------------"- COMTRAN M6W 18 6.7000 4 COND.SOLID COPPER FPLR ANALOG UNSHIELDED Boeing 40-029 m <br /> FAX: (866)798-9241 a„e PMmer•r Ra 9115 <br /> N4Q N79 Boeing40-889 <br /> E, <br /> APPLICABLE CODES AND STANDARDS 75tb St sw <br /> NFPA 72 NATIONAL FIRE ALARM CODE 2019EDITION GENERAL NOTES Boeing40-569 Boeing40-589 F--SnohomishcountyPUD, <br /> INTERNATIONAL BUILDING CODE 2015 EDITION <br /> ! -Operations Center <br /> INTERNATIONAL FIRE CODE 2015 EDITION <br /> NFPA 70 NATIONAL ELECTRICAL CODE 2020 EDITION • ALL FIRE ALARM SYSTEM WORK COMPLETED UNDER THE SCOPE OF THIS FIRE ALARM PLAN REVIEW SHALL BE FIELD VERIFIED BY FIRE INSPECTION <br /> PERSONNEL AND THE FIRE CODE OFFICIAL. N <br /> • VISIBLE NOTIFICATION APPLIANCES SHALL REMAIN ACTIVE(FLASHING)WHEN THE AUTOMATIC AND MANUAL FIRE ALARM SYSTEM IS SILENCED. Z <br /> • FIRE ALARM SYSTEM SHALL TRANSMIT TROUBLE,SUPERVISORY AND FIRE SIGNALS DIRECTLY TO THE COMMUNICATIONS CENTER REMOTE SUPERVISING O <br /> STATION. VICINITY MAP <br /> CIRCUIT LABELING LEGEND MOUNT PULL STATIONS AT42"AT ACTIVATOR WITHIN 5'OF LATCH SIDE OF EXIT DOORS <br /> • MOUNT AUDIO VISUAL DEVICES AT 80"ABOVE FLOOR LEVEL <br /> • A DEDICATED 120VAC,20A BRANCH CIRCUIT BREAKER SHALL BE PROVIDED,MARKED IN RED,LOCK-ON PROVISION AND IDENTIFIED AS"FIRE ALARM <br /> DEVICE IDENTIFIER CIRCUIT CONTROL".THE LOCATION OF THE CIRCUIT BREAKER WILL BE PERMANENTLY IDENTIFIED AT THE FIRE ALARM CONTROL UNIT. <br /> SLC1•### SLC=SIGNALING LINE CIRCUIT <br /> NAC=NOTIFICATION APPLIANCE CIRCUIT <br /> CIRCUIT IDENTIFIER <br /> SHEET INDEX <br /> ABBREVIATIONS SHEET NO. SHEET DESCRIPTION <br /> FAD.1 TITLE SHEET <br /> .IIIIIIII� IrL <br /> A AMPERE J-BOX JUNCTION BOX FAO.2 OVERALL BUILDING PLAN-FIRE ALARM SYSTEM <br /> AFF ABOVE FINISHED FLOOR kV KILOVOLT <br /> AHU AIR HANDLING UNIT kVA KILOVOLT AMPERE FA1.1 FLOOR PLAN SOUTH-FIRE ALARM SYSTEM <br /> IMMM <br /> AL ALUMINIUM kW KILOWATT FIRE ALARM SYSTEM OUTPUTS FA1.2 FLOOR PLAN NORTH-FIRE ALARM SYSTEM Q u II <br /> AMP AMPERE kWh KILOWATT HOUR LU (1, W <br /> AWG AMERICAN WIRE GAUGE MFR MANUFACTURER FACP& C.S. NOTIFICATION FA2.1 FIRE ALARM RISER DIAGRAM&CIRCUIT CALCULATION LU > O <br /> BLDG BUILDING MECH MECHANICAL ANNUNCIATORS MONITORING &CONTROL EQUIPMENT <br /> C CONDUIT MIN MINIMUM <br /> CB CIRCUIT BREAKER (A) NEW -1 I I <br /> CCTV CLOSED CIRCUIT TELEVISION NAC NOTIFICATION APPLIANCE CIRCUIT qCS, 'v W <br /> CKT CIRCUIT NEC NATIONAL ELECTRIC CODE <br /> CLG CEILING NEUT NEUTRAL <br /> CO CONDUITONLY NFPA NATIONAL FIRE PROTECTION ASSOCIATION �./Sp�gLglq �.P F,9 �PK. TYPICAL DEVICE MOUNTING DETAIL IO W <br /> COMM COMMUNICATION NC NORMALLY CLOSED <br /> CU COPPER NIC NOT IN CONTRACT �`gGfB� lC2<<tS Gp F.t, ROOF DECK li <br /> DCV DOUBLE CHECK VALVE NO NUMBER;NORMALLY OPEN O cc 9 f 6 �O `9 G` MOUNTTo <br /> DIA DIAMETER NTS NOT TO SCALE gG�lfe�/.S J C�Yq� lFj����L �O STRUCTURE <br /> DISC DISCONNECT OD OVERHEAD DOOR;OVERALL DIAMETER 6� i�G°C''C c �s `�° BASE HEAD <br /> DIN DOWN PIV POST INDICATOR VALVE �2f.�SG�y.�'L�j,�'� Gq���,p YG J.BOX ABOVE CEILINGJ-Box LU <br /> DO DOOR OPERATOR PNL PANEL sG q� G.o 9,oA OB .p S,S, LU <br /> (E) EXISTING PVC POLYVINYL CHLORIDE(PLASTIC) qt' F'P .1y, `rT Fj,'Y° SUPPORT SUPPORT <br /> BRACKET BRACKET <br /> EF EXHAUSTFAN QTY QUANTITY FIRE ALARM SYSTEM INPUTS qEA EACH PWR POWER `IT, Fs°��'�O2'�O� ��FS'�4��°`�2 PLASTER RING N <br /> ELEC ELECTRIC REQD REQUIRED SYSTEM SMOKE/HEAT DETECTORS �`sE HEAD CEILING I� <br /> ELEV ELEVATOR RH RANGE HOOD SMOKE OR HEAT DETECTOR MANUAL PULL STATION NOTIFICATION <br /> CEILING MOUNT <br /> NonFican O <br /> EMT ELECTRICAL METALLIC TUBING RMC RIGID METALLIC CONDUIT <br /> EOL END OF LINE RESISTOR SF SUPPLY FAN;SQUARE FEET SYSTEM TROUBLE 0 0 1M' <br /> EOLR END OF LINE RESISTOR SLC SIGNALING LINE CIRCUIT BATTERY FAULT 0 0 � 1'1 I I <br /> W EXIST EXISTING SPEC SPECIFICATION ` <br /> F FIXED ST SHUNT TRIP OPEN CIRCUIT/SHORT 0 WALL MOUNT W �/ <br /> FA FIRE ALARM STD STANDARD GROUND FAULT NOTIFICATION APPLIANCE ` J <br /> FAA FIRE ALARM ANNUNCIATOR TEL TELEPHONE <br /> FACP FIRE ALARM CONTROL PANEL TELCO TELEPHONE COMPANY LOSS OF PRIMARY POWER 4 t^ I I <br /> FAPS FIRE ALARM POWER SUPPLY TEMP TEMPORARY ® Q / <br /> FARA FIRE ALARM REMOTE ANNUNCIATOR TS TAMPER SWITCH GENERAL NOTES: <br /> FBO FURNISHED BY OTHERS TYP TYPICAL • REFERENCE NUMBERS ARE SHOWN IN PARENTHESES(1)FOR"NOTES/NOTATIONS"INDICATED BELOW AND IN <br /> FDC FIRE DEPARTMENT CONNECTION UGND UNDERGROUND HEADINGS TO THE RIGHT. FIRE ALARM <br /> FEC FIRE EXTINGUISHER CABINET ILL UNDERWRITERS LABORATORIES • FIRE ALARM SYSTEM DEVICES ARE POINT ADDRESSABLE. CONTROL PANEL <br /> FH FIRE HYDRANT UON UNLESS OTHERWISE NOTED <br /> FPL FIRE POWER LIMITED V VOLT —FIRE ALARM <br /> FPLR FIRE POWER LIMITED RISER VA VOLTAMPERE ANNUNCIATOR H— <br /> FPLP FIRE POWER LIMITED PLENUM VAC VOLTAGE,ALTERNATING CURRENT <br /> FS WATER FLOW SWITCH VDC VOLTAGE,DIRECT CURRENT MANUAL ■ ■ w <br /> FSD FIRE/SMOKE DAMPER VR VANDAL RESISTANT ® PULL W 2 <br /> BB STATION <br /> G GROUND W WATT 000mm <br /> GEC GROUNDING ELECTRODE CONDUCTOR W/ WITH <br /> GEN GENERATOR W/0 WITHOUT ,`a JRC <br /> HT HEATTRACE WP WEATHERPROOF DRAwNer: <br /> IDC INITIATING DEVICE CIRCUIT Z IMPEDANCE Adrian I, <br /> 72' 60' 80" CHECKED BY: Adrian M. Stelk <br /> PLOT DATE: 3/11/2 3 <br /> PROJECT NUMBER: 2 3-025 <br /> I <br /> 1 <br /> FAO , <br /> DRAWING ONLY TO SCALE IF PLOTTED AT 30"X 42"' SHEET NUMBER: <br />
The URL can be used to link to this page
Your browser does not support the video tag.