Laserfiche WebLink
EXECUTIVE SUMMARY <br />At the request of Ms. Ashley Previs on behalf of Veritas Construction, Inc. (Client), Earth <br />Solutions NW, LLC (ESNW) has completed a Phase I Environmental Site Assessment (ESA) <br />for the subject site located northwest of the terminus of 36t' Avenue West in Everett, <br />.� Washington (see Vicinity Map - Plate 1). This Phase I ESA was prepared in general <br />accordance with the American Society for Testing and Materials (ASTM) Standard Practice for <br />Environmental Site Assessments: Phase I Environmental Site Assessment Process, <br />Designation E-1527-13. <br />The site consists of consists of one tax parcel (Snohomish County Parcel Number <br />28040300200100) comprising a total of 39.48-acres of land area (see Site Plan - Plate 2). The <br />site is currently undeveloped forested land. We understand development of a light industrial <br />business center is currently proposed at the subject property. The proposed development will <br />include a series of warehouse/office buildings, paved parking and drivelanes, and associated <br />infrastructure improvements. <br />No hazardous materials spills, staining, stressed vegetation, or other visible signs of hazardous <br />materials release were noted at the site. The subject site is not a recorded source of soil or <br />groundwater contamination. <br />No underground storage tanks (USTs) or above ground storage tanks (ASTs) were listed on <br />the regulatory databases for the subject property or observed during the site reconnaissance. <br />Visual observation did not reveal vent pipes or fill ports associated with underground storage <br />tanks on the subject property. <br />The Environmental Data Resources Inc. (EDR) report did not identify the subject site on federal <br />and state regulatory databases. The EDR report did identify one nearby property on the state <br />regulatory database, CSCSL list. However, given the distance between the listed site and the <br />subject site and the inferred hydraulic groundwater gradient, the listed site does not represent <br />an environmental concern to the subject property. <br />The reconnaissance of the subject property and adjacent properties, a review of regulatory lists <br />and files, a review of the subject property history, and interviews with knowledgeable persons <br />revealed no recognized environmental conditions (RECs) in connection with the subject site. <br />Please see section 8.1 of this report for overall recommendations regarding the subject site. <br />This is an executive summary of findings and should not be relied upon without consulting the <br />attached report for a more detailed description of the Phase I ESA performed by ESNW for of <br />Veritas Construction, Inc. This report is subject to the limitations included in Section 1.5 of this <br />report. <br />Earth Solutions NW, LLC <br />