My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2801 BAKER AVE 2025-04-09
>
Address Records
>
BAKER AVE
>
2801
>
2801 BAKER AVE 2025-04-09
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/9/2025 8:57:03 AM
Creation date
4/9/2025 8:49:44 AM
Metadata
Fields
Template:
Address Document
Street Name
BAKER AVE
Street Number
2801
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
66
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■n SFM FRAME <br />MICRDRAIL 71 <br />kiIAPJlAli W aIN*011 471aINAIM11 <br />UL CODE COMPLIANCE NOTES ■ <br />INSTALLATION GUIDE I PAGE <br />The system fire class rating requires installation in the manner specified in the performance Is Inherent In the SFM design, and no additional mitigation measures <br />SUNFRAME MICRORAIL(SFM) Installation Guide SFM has been classified to are required. The fire classification rating is valid for any roof pitch .There isno <br />the system level fire portion of UL 1703. This UL 1703 classification has been required minimum or maximum height limitation above the roof deck to maintain <br />incorporated into the UL 2703 product certification SFM has achieved Class A, the Class A,B& C fire rating for SFM. SUNFRAME MICRORAIL components shall <br />B& C system level performance for lowslope& steep sloped roofs when used be mounted over a fire resistant roof covering rated for the application. <br />in conjunction with type 1 and type 2 modules. Class A, B & C system level fire <br />Module <br />Type <br />Roof Slope <br />System Level Fire <br />Rating <br />Micr it Direction <br />i Module Orientation <br />Mitigation <br />Required <br />Type 1 <br />and T <br />e2 <br />Steep Slope & <br />Low Slope <br />I Class A,B&C <br />I East West <br />I Landscape OR Portrait <br />None Required <br />UL2703 TEST MODULES <br />See pages 22 and 23 for a list of modules that were electrically and mechanically tested or <br />qualified with the SUNFRAME M ICRORAIL (SFM) components outlined within this Installation Guide. <br />Maximum Area of Module =2776 sgft <br />UL2703 Design Load Ratings <br />a) <br />Downward Pressure —113 PSF/5400 Pa <br />b) <br />Upward Pressure —50 <br />PSF/2400 Pa <br />c) <br />Down -Slope Load <br />—21.6 PSF/1034 Pa <br />Tested <br />Loads. <br />a) <br />Downward Pressure <br />—170 PSF/8000 Pa <br />b) <br />Upward Pressure— <br />75 PSF/3500 Pa <br />c) <br />Down -Slope Load <br />—32.4 PSF/1550 Pa <br />Maximum Span = 6ft <br />Use with a maximum over current protection device OCPD of 30A <br />System conforms to ULStd 2703, certified to LTRAE-001-2012 <br />Rated fora design load of 2400 Pa/5400 Pa with 24 inch span <br />PV modules may have a reduced load rating, independent of the SFM load rating. Please consult <br />the PV module manufacturer's installation guide for more information <br />Down Slope design load rating of 30 PSF/ 1400 Pa for module areas of 223 sq ft or less <br />aVaav_ATUR <br />osMXBWi CM <br />HERBNCOWANEDSHALLNOTBE <br />SEDFORTHEBENEFUMME <br />CONTRACTOR'. <br />BPS FIELD OPs <br />385 498 6700 <br />SPEC SHEET <br />so» AGE55 <br />
The URL can be used to link to this page
Your browser does not support the video tag.