Laserfiche WebLink
A This is a beta release of the new ATC Hazards by Location website.Please contact us with feedback <br /> 0 The ATC Hazards by Location website will not be updated to support ASCE 7-22.Find out why_ <br /> L1TC Hazards by Location <br /> Search Informationptiot„ Granite Falls <br /> ulalip Getchell <br /> Address: Everett,WA 98201,USA fit ft'�'lle - Lochsloy <br /> Coordinates: 47.9990269,-122.1914014 • O <br /> ei.m°i - 4111•hfdbey .77: Lake Stevens <br /> Elevation: 62 ft aw tin Aland Until? v Brett Lake Roesiger <br /> Timestamp: 2023-05-25T22:52:51.905Z Q °' -► ` <br /> A <br /> Hazard Type: Seismic laMite() r t; i ' <br /> i 0 t <br /> Reference Document: ASCE7-16 lei • ,''i' <br /> - Map data©2023 Google Report a map error <br /> Risk Category: II <br /> Site Class: D-default <br /> Basic Parameters <br /> Name Value Description <br /> SS 1.194 MCER ground motion(period=0.2s) <br /> Sr 0.424 MCER ground motion(period=1.0s) <br /> SMS 1.432 Site-modified spectral acceleration value <br /> SMt *null Site-modified spectral acceleration value <br /> SOS 0.955 Numeric seismic design value at 0.2s SA <br /> SO1 *null Numeric seismic design value at 1.0s SA <br /> 'See Section 11 4.8 <br /> Additional Information <br /> Name Value Description <br /> SDC *null Seismic design category <br /> Fa 1.2 Site amplification factor at 0.2s <br /> Fv 'null Site amplification factor at 1.0s <br /> CRs 0.906 Coefficient of risk(0.2s) <br /> CR1 0.893 Coefficient of risk(1.Os) <br /> PGA 0.511 MCEG peak ground acceleration <br /> FpGA 1.2 Site amplification factor at PGA <br /> PGAM 0.613 Site modified peak ground acceleration <br /> TL 6 Long-period transition period(s) <br /> SsRT 1.194 Probabilistic risk-targeted ground motion(0.2s) <br /> SsUH 1.317 Factored uniform-hazard spectral acceleration(2%probability of <br /> exceedance in 50 years) <br /> SsD 2.985 Factored deterministic acceleration value(0.2s) <br /> S1RT 0.424 Probabilistic risk-targeted ground motion(1.Os) <br /> Si UH 0.475 Factored uniform-hazard spectral acceleration(2%probability of <br /> exceedance in 50 years) <br /> S1D 1.116 Factored deterministic acceleration value(1.0s) <br /> PGAd 1.023 Factored deterministic acceleration value(PGA) <br /> See Section 11 4.8 <br /> The results indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any <br /> output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design <br /> Please note that the ATC Hazards by Location website will not be updated to support ASCE 7-22.Find out why <br /> Disclaimer <br /> L\ I 5 2 <br />