2 of 5 <br />The results are summarized below: <br />Typical Piles: <br />Maximum Demand (allowable): 14.0 kips/pile <br />Available Capacity (allowable): 25.2 kips/pile <br />By inspection, the pile capacities of the installed piles exceed the maximum loading demand as determined <br />by L120's analysis. Therefore, the installed piles comply with the structural design/demand. <br />Please contact us if you have any questions. <br />Sincerely, <br />Jason Tien <br />L120 Engineering & Design (L120) <br />jtien@1120engineering.com <br />Mans R. Thurfjell, P.E. <br />L120 Engineering & Design (L120) <br />mthurfjell@1120engineering.com <br />* F A a f <br />TOUR*+• <br />4r S ': .0 f <br />� Y <br />■ r <br />• NAL • <br />