My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1326 55TH ST SW 2025-08-20
>
Address Records
>
55TH ST SW
>
1326
>
1326 55TH ST SW 2025-08-20
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/20/2025 1:40:15 PM
Creation date
4/9/2025 2:11:35 PM
Metadata
Fields
Template:
Address Document
Street Name
55TH ST SW
Street Number
1326
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'AirvrcIcvvCa <br /> vgt.iviksi=ic lltrvatii <br /> Level, BM-1 <br /> 1 piece(s)5 1/2"x 7 1/2" 24F-V4 DF Glulam <br /> _ ._•a __ 1t1: E. 1 <br /> M <br /> 0 0 <br /> I I <br /> r <br /> 3 1•: 1:2 <br /> II 0 <br /> All locations are measured from the outside face of left support(or left cantilever end).All dimensions are horizontal. <br /> Design Results Actual B Location Allowed Result LDF Load:Combination(Pattern) System:Roof <br /> Member Reaction(Ibs) 3311 @ 2" 12513(3.50") Passed(26%) -- 1.0 D+1.0 L(All Spans) Member Type:Drop Beam <br /> Building Use:Residential <br /> Shear(Ibs) 2669 @ 11" 7288 Passed(37%) 1.00 1.0 D+1.0 L(All Spans) Building Code:IBC 2018 <br /> Pos Moment(Ft-Ibs) 7286 @ 4'8 3/4" 10313 Passed(71%) 1.00 1.0 D+1.0 L(All Spans) Design Methodology:ASD <br /> Live Load Defl.(in) 0.215 @ 4'8 3/4" 0.456 Passed(L/509) -- 1.0 D+1.0 L(All Spans) Member Pitch:0/12 <br /> Total Load Defl.(in) 0.314 @ 4'8 3/4" 0.608 Passed(L/349) -- 1.0 D+1.0 L(All Spans) <br /> • Deflection criteria:LL(L/240)and TL(L/180). <br /> •Allowed moment does not reflect the adjustment for the beam stability factor. <br /> •Critical positive moment adjusted by a volume factor of 1.00 that was calculated using length L=9'1 1/2". <br /> •The effects of positive or negative camber have not been accounted for when calculating deflection. <br /> •The specified glulam is assumed to have its strong laminations at the bottom of the beam.Install with proper side up as indicated by the manufacturer. <br /> •Applicable calculations are based on NDS. <br /> Bearing Length Loads to Supports(Ibs) <br /> Supports Total Available Required Dead Floor Live Roof Live Snow Factored Accessories <br /> 1-Column-HF 3.50" 3.50" 1.50" 1041 2270 189 236 3311 Blocking <br /> 2-Column-HF 3.50" 3.50" 1.50" 1041 2270 189 236 3311 Blocking <br /> •Blocking Panels are assumed to carry no loads applied directly above them and the full load is applied to the member being designed. <br /> Lateral Bracing Bracing Intervals Comments <br /> Top Edge(Lu) 9'6"o/c <br /> Bottom Edge(Lu) 9'6"o/c <br /> •Maximum allowable bracing intervals based on applied load. <br /> Dead Floor Live Roof Live Snow <br /> Vertical Loads Location(Side) Tributary Width (0.90) (1.00) (non-snow:1.25) (1.15) Comments <br /> 0-Self Weight(PLF) 0 to 9'5 1/2" N/A 10.0 -- -- <br /> 1-Uniform(PSF) 0 to 9'5 1/2"(Front) 12' 15.0 40.0 - - Default Load <br /> 2-Uniform(PSF) 0 to 9'5 1/2"(Front) 2' 15.0 - 20.0 25.0 <br /> Weyerhaeuser Notes <br /> Weyerhaeuser warrants that the sizing of its products will be in accordance with Weyerhaeuser product design criteria and published design values.Weyerhaeuser expressly disclaims any other warranties <br /> related to the software.Use of this software is not intended to circumvent the need for a design professional as determined by the authority having jurisdiction.The designer of record,builder or framer is <br /> responsible to assure that this calculation is compatible with the overall project.Accessories(Rim Board,Blocking Panels and Squash Blocks)are not designed by this software.Products manufactured at <br /> Weyerhaeuser facilities are third-party certified to sustainable forestry standards.Weyerhaeuser Engineered Lumber Products have been evaluated by ICC-ES under evaluation reports ESR-1153 and ESR-1387 <br /> and/or tested in accordance with applicable ASTM standards.For current code evaluation reports,Weyerhaeuser product literature and installation details refer to <br /> www.weyerhaeuser.com/woodproducts/document-library. <br /> The product application,input design loads,dimensions and support information have been provided by ForteWEB Software Operator <br /> ForteWEB Software Operator Job Notes 8/24/2022 10:43:16 PM UTC <br /> Caitlin Wilhelm,PE <br /> Caitlin Rose Engineering,LLC ForteWEB v3.4, Engine: V8.2.2.122, Data:V8.1.2.2 <br /> (360)982-1115 <br /> caitlin@caitlinroseengineering.com Weyerhaeuser File Name: 22-29-Kaas Addition <br />
The URL can be used to link to this page
Your browser does not support the video tag.