Laserfiche WebLink
• <br /> Project Name/Number:retain pro <br /> Use menu item Settings> Printing&Title Block Title 9649-6' Page 2 <br /> to set these five lines of information Dsgnr: chris Date. '5 SEP 2022 <br /> for your program. Description..., <br /> This Wall in File: C:\Users\Chris\Desktop\retain pro.RPX <br /> lietainPro(c)19E7-2018, Build i1.18.12.04 <br /> License:KW-06060593 Cantilevered Retaining Wall Code: IBC 2012,ACI 318-11,ACI 530-11 <br /> License To:STRUCTURAL DESIGN ASSOCIATES <br /> Concrete Stem Rebar Area Details <br /> Bottom Stem Vertical Reinforcing Horizontal Reinforcing <br /> As(based on applied moment): 0.0873 in2/ft <br /> (4/3)*As: 0.1164 in2/ft Min Stem T&S Reinf Area 1.152 in2 <br /> 200bd/fy:200(12)(6.25)/40000: 0.375 in2/ft Min Stem T&S Reinf Area per ft of stem Height:0.192 in2/ft <br /> 0 0018bh:0.0018(12)(8): 0.1728 in2/ft Horizontal Reinforcing Options. <br /> One layer of: Two layers of: <br /> Required Area: 0.1728 in2/ft #4@ 12.50 in #4@ 25.00 in <br /> Provided Area: 0.2 in2/ft #5@ 19.38 in #5@ 38.75 in <br /> Maximum Area• 1.27 in2/ft #6@ 27.50 in #6@ 55.00 in <br /> Footing Dimensions&Strengths 1 Footing Design Results <br /> Toe Width = 1.25 ft Toe Heel <br /> Heel Width = 1.75 . Factored Pressure = 1,668 740 psf <br /> Total Footing Width = 3.00 Mu': Upward - 1,203 500 ft-# <br /> Footing Thickness = 10.00 in Mu': Downward = 219 514 ft-# <br /> Mu: Design = 984 14 ft-# <br /> Key Width = 12.00 in Actual 1-Way Shear = 9.27 0.36 psi <br /> Key Depth = 12.00 in Allow 1-Way Shear = 40.00 40.00 psi <br /> Key Distance from Toe = 2.00 ft Toe Reinforcing = #4 @ 9.99 in <br /> fc = .500 psi Fy = 40,000 psi Heel Reinforcing = #4 @ 9.99 in <br /> Footing Concrete Density = 150.00 pcf Key Reinforcing = None Spec'd <br /> Min As% = 0.0018 Other Acceptable Sizes&Spacings <br /> Cover @ Top 2.00 @ Btm= 3.00 in <br /> Toe: Not req'd:Mu<phi"5*lambda*sgrt(fc)"Sm <br /> Heel:Not req'd:Mu<phi*5*lambda*sgrt(fc)*Sm <br /> Key: Not req'd:Mu<phi*5*lambda*sgrt(fc)*Sm <br /> Min footing T&S reinf Area 0.65 in2 <br /> Min footing T&S reinf Area per foot 0.22 in2 /ft <br /> If one layer of horizontal bars: If two layers of horizontal bars, <br /> #4@ 11.11 in #4@ 22.22 in <br /> #5@ 17.22 in #5@ 34.44 in <br /> #6@ 24.44 in #6@ 48.89 in <br /> Summary of Overturning& Resisting Forces & Moments <br /> ANcsbAnimmaimtai <br /> OVERTURNING RESISTING <br /> Force Distance Moment Force Distance Moment <br /> Item lbs ft ft-# lbs ft ft-# <br /> Heel Active Pressure = 701 9 2.11 1,481.9 Soil Over Heel = 655.4 2.46 1,611.2 <br /> Surcharge over Heel = Sloped Soil Over Heel = <br /> Surcharge Over Toe = Surcharge Over Heel = <br /> Adjacent Footing Load = Adjacent Footing Load = <br /> Added Lateral Load = Axial Dead Load on Stern= 750.0 1.58 1,'i 87-5 <br /> Load @ Stem Above Soil= `Axial Live Load on Stem = 500.0 1.58 791 7 <br /> = Soil Over Toe - 0.63 <br /> Surcharge Over Toe = 50.0 0.63 31 3 <br /> Total 701.9 O.T.M. 1,481.9 Stem Weight(s) = 600.0 1.58 950 0 <br /> Earth @ Stem Transitions= <br /> = = Footing Weight = 375 0 1 50 562 5 <br /> Resisting/Overturning Ratio = 3.18 Key Weight = 150.0 2,50 375.0 <br /> Vertical Loads used for Soil Pressure= 3,080.4 lbs Vert.Component = <br /> Total= 2,580.4 lbs R.M.= 4,717.5 <br /> *Axial live load NOT included in total displayed or used for overturning <br /> resistance,but is included for soil pressure calculation <br /> Vertical component of active lateral soil pressure IS NOT considered in <br /> the calculation of Sliding Resistance. <br /> Vertical component of active lateral soil pressure IS NOT considered in <br /> the calculation of Overturning Resistance. <br /> 21ISS <br />