Laserfiche WebLink
MITI <br /> Hilts PROM Engineering 3.0.40 <br /> www.hilti.com • <br /> Company: Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: 45-767 Date: 4/5/2019 <br /> Fastening point: <br /> 4 Shear load <br /> Load V.[Ib) Capacity 4 V.Lib] Utilization Yy=V./0 V. Status <br /> Steel Strength' 2,960 4,940 60 OK <br /> Steel failure(with lever arm)' N/A N/A N/A N/A <br /> Pryout Strength'" 2,960 12,042 25 OK <br /> Concrete edge failure in direction x+•' 2,960 7,381 41 OK <br /> 'highest loaded anchor "anchor group(relevant anchors) <br /> 4.1 Steel Strength <br /> =ESR value refer to ICC-ES ESR-1917 <br /> 4 V, ,2 V„a ACI 318-14 Table 17.3.1.1 <br /> Variables <br /> As..v rn') f„t,[psi] <br /> 0.16 106,000 <br /> Calculations <br /> Vu.w[lb] 11111 <br /> 7,600 <br /> Results <br /> V„..[lb] +0.4 OnonductlN 4 VM..[Ib] V.(Ib) <br /> 7,600 0.650 1.000 4,940 2,960 <br /> i <br /> Input data and restate must be checked for conformity with the existing conditions and for plausibility) <br /> PROFIS Engineering(c)2003.2009 HIIO AG,FL-9494 Schaan Hid is a registered Trademark of kith AG,Schoen <br /> 04/05/19 Boeing Flightline Stall 113 Page 116 <br />