My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-05 2025-04-14
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-05
>
3003 W CASINO RD BLDG 45-05 2025-04-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/14/2025 7:51:54 AM
Creation date
4/14/2025 7:46:39 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-05
Imported From Microfiche
No
该页面上没有批注。
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
166
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AFT HARDSTAND FOUNDATION <br /> Pole Foundation Gravity and Lateral Design <br /> Per IBC 2015 Section 1807.3 <br /> Input <br /> Service Vertical Load, Pv 250 lbs <br /> Service Lateral Load, PH 250 lbs h „„ <br /> Height of Pa Above Ground Surface, h 4.0 ft <br /> Allowable Vertical Bearing Pressure, ov 1500 psf ''�` —_- <br /> Allowable Lateral Bearing Pressure' <br /> Per Foot Below Grade,7Kp 303 psi/ft' 1MIT4 iKCD S1 <br /> curio i n on b Cl <br /> Output <br /> Min Pole Diameter for Vertical Load, brt.N = 0.5' ft Si <br /> trtt <br /> Pole Diameter Override, b' 1.6 ft <br /> cc- <br /> Figure 1 <br /> Uniform Allowable Lateral Bearing Pressure IYICel/3 <br /> for Peon-Constrained Pole, Si = 30d' psf 5, 'y <br /> ft <br /> A= 1.22' ft R � <br /> • <br /> I lion-Constrained Pole Depth Required,d = 3.Q0' ft — - — <br /> 2 Constrained Pole Depth Required,d = 2.50 ft Figure 2 <br /> i lion-Constrained: No constraint provided at the ground surface, such as a rigid floor or <br /> rigid ground surface pavement, and no lateral constraint is provided above the ground <br /> surface, such as a structural diaphragm. [per IBC 2009 Section 1807.3.2.1] <br /> 2 Constrained: Constraint is provided at the ground surface, such as a rigid floor or rigid <br /> ground surface pavement. [per IBC 2009 Section 1807.3.2.2) <br /> Limitations: Pole foundations shall not be used to provide lateral support for structural or <br /> non-structural materials such as plaster, masonry or concrete unless adequate bracing is <br /> provided to limit deflections as required. <br /> Allowable Increases: The values generated by the equations above are intended to <br /> minimize movement at the ground surface. If short-term ground surface movements up to <br /> 1/2"are acceptable for the structure under consideration, IBC 2009 Section 1606,3.4 <br /> permits a 100%increase in lateral bearing pressure,-;Kp. Additionally, an increase in 7Ka of <br /> one-third is permitted when using the alternate load combinations in IBC 2009 Section <br /> 1605.3.2 that include wind and earthquake loads. <br /> • Bacicfill Requirements: See IBC Section 2009 1807.3.3 for backfill requirements at pole foundations. <br /> - br <br /> ACOFFMAN location ab <br /> NGINEERS danllob <br /> no <br /> 04/0 Boeing Fliahtline Stall 113 �«*� Page 13 <br /> Oats <br />
The URL can be used to link to this page
Your browser does not support the video tag.