Command Centers Installation, Warranty, and Training <br /> System command centers shall be Radionics D1255 Installation of the system, wiring of initiating devices and <br /> Command Center, D1256 Fire Command Center, and signaling circuits shall be the responsibility of the <br /> D1257 Fire Annunciator. Each of these shall be equipped installing company. <br /> with a 16-character alphanumeric display, distinct fire and <br /> burglary tones, and backlighted multi-key touchpad. Warranty on all components shall be for one year, subject <br /> to manufacturer's limitations. Training in the complete <br /> The D1255, D1256, and D1257 shall have the ability to operation of the system shall be furnished by the <br /> display the following for each detection point: alarm, installing company upon completion of the installation. <br /> trouble, service,faulted, and custom text. In addition, <br /> expanded, addressable point displays shall include Listings and Approvals <br /> missing and extra, point information. System wide <br /> displays shall include: local system test, sensor reset, Fire <br /> fire test mode, and user programming prompts. UL: Central Station, Local, Auxiliary, Remote Station, and <br /> Remote Diagnostics and Controls Household Fire Warning. <br /> Remote control through the use of the Remote Account CFSM,FM and NYC-MEA approved. <br /> Manager software shall include: reset of audible signals, <br /> activation/deactivation of D8129 relays, interrogation of Burglary <br /> battery, point and armed status, the enabling or disabling UL: Central Station, Local, Police Connect, Bank Safe and <br /> of reporting functions, and the shunting of reporting points Vault, Mercantile Safe and Vault, and Grade A Household <br /> during servicing. systems. <br /> System Test DOD: Approved for installations in Sensitive Compart- <br /> The Fire Test mode shall support single person mented Information Facilities (SCIF). <br /> operation. All reports to the central station shall be <br /> suppressed while the fire test is being conducted. The <br /> Fire Test mode shall be activated by entering a user <br /> passcode at the D1255R. All testing data shall be visible <br /> on command center and annunciator displays during <br /> testing. <br /> Hardware <br /> The D9112 shall provide up to 246 individually identified <br /> addresses. Each shall accommodate normally open and/ <br /> or normally closed devices with End-Of-Line resistor <br /> supervision. Each point shall be programmable for fire, <br /> fire supervisory or burglary applications. Also, silent or <br /> steady and/or pulsed audible, and local or remote <br /> reporting to a receiver. <br /> External Hardware <br /> The D9112 shall allow the use of up to three on-site <br /> parallel printers using Radionics D9131A Printer Interface <br /> Modules. Events shall print as they are stored in logger. <br /> The printer shall print the time, date, account number, <br /> event,point ID,point text and user text. <br /> Radionics' <br /> © 1997 Radionics,Inc.,Salinas,CA, USA.All rights reserved. ISO 9002 <br /> Ell <br /> nA The Radionics logo is a registered trademark of Radionics, Inc.,Salinas,CA. CERTIFICATE NO.3946 <br /> L772 P/N 32236C (10/97) Radionics, Inc., 1800 Abbott Street, L772 P/N 32236C <br /> Salinas,CA,93901, U.S.A. <br /> 38 <br />