Laserfiche WebLink
FIELD DENSITY TESTING REPORT <br />MAYES lferracon <br />Report Number: M7231404.0015 <br />Service Date: 10/06/23 <br />Report Date: 10/10/23 <br />Client <br />Brixton Everett LLC <br />Attn: Kyle Godat <br />120 S Sierra Ave <br />Solana Beach, CA 92075 <br />Permit No.: B2208-032 <br />20225 Cedar Valley Rd Ste 110 <br />Lynnwood, WA 98036-6365 <br />425-742-9360 <br />Project <br />Everett Mall Redevelopment <br />1402 SE Everett Mall Way <br />Everett, WA <br />Project Number: M7231404 <br />General Information <br />Joe Lang with Bayley Construction requested Mayes Terracon be on site for field density testing and fill <br />placement observation. Earthwork is being performed by Bayley Construction. The results of observation(s) for <br />today were reported to Joe Lang. Mayes Terracon representative arrived on site at 1030 and departed at 1130. <br />The construction documents referenced for this inspection include the Permit Set. <br />Observed Locations <br />Future Trader Joe's, grid lines B-D/1-7 slab -on -grade <br />Fill Placement <br />Fill Type Placed Proctor No.(s) Fill Description Source of Fill <br />Existing native subgrade 0013A Coarse sand with silt On site existing native subgrade <br />The fill placed appeared firm and stable during the application of compaction efforts. <br />Density Test Results <br />Field density tests were conducted on the previously placed fill utilizing the nuclear method (ASTM D6938). Four <br />field density tests were performed. The test results met the minimum specified 95% compaction requirement as <br />compared to ASTM D 1557 test method. Refer to the attached field density test report for individual test data. <br />Additional Comments <br />Existing native subgrade was moistened and compacted. No fill material was placed. <br />Compliance Statement <br />Based on our observations and/or tests fill placement activities as detailed above appear to be completed in <br />general accordance with the project plans and specifications. <br />Services: Special Inspections / Materials Testing <br />Mayes/Terracon Rep.: Carl Harrington <br />Reported To: Bayley Construction <br />Contractor: Bayley Construction <br />Report Distribution: <br />(1) Brixton Everett -LC, Kyle Godat (1) Bayley Construction, Tony Betz <br />(1) Mayes Testing Engineers, Inc, (1) Mayes Testing Engineers, Inc, Mike <br />Donna Pollard Mattox <br />Reviewed By: '_. V_ )_.___ <br />�/ Barry Tuttle <br />Project Field Manager <br />The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above <br />and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at <br />the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. <br />DM007, 04-29-22 Rev9 Page 1 of 1 <br />