Advanced Blower Door Test Company <br /> Curleata Reykdal - Owner/President Phone Number: 425.870.1837 <br /> Technician Name: Curleata Reykdal Date: q 1 7-02-1; <br /> Permit#: Age of House: od M — rj <br /> House address & lot#: <br /> Ave- <br /> City: Icy I State:WA jZip Code: <br /> Source (circle one): PLANS ESTIMATED MEASURED <br /> Weather Conditions: Iclear lRain vercast i n d I 10ther: <br /> Test Required: S.0 Passing Failing <br /> Conditioned Floor Area: <br /> Volume : <br /> ACH: y . Fj <br /> CFM: n . <br /> Fan Location: rr v v <br /> Ring (Circle one) Open A B Jg <br /> I certify that these blower door results are accurate and determined using standard industry protocol: <br /> Company Name: Advanced Blower Door Test Company <br /> Technician Signature: Date: <br /> e erence: <br /> R402.4.1 Testing-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 <br /> ACH50.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). For this test only, the <br /> volume of the home shall be the conditioned floor area on ft2 (2)multiplied by 8.5 feet(2.6m) Where required by the code <br /> official, testing shall be conducted by an approved third party. A written report of the results shall be signed by the party <br /> conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations <br /> of the building thermal envelope. Once visual inspection has confirmed sealing (see Table R402.4.1.1), operable windows and <br /> doors manufactured by small business shall be permitted to be sealed off at the frame prior to the test. <br /> During Testing: 1.LExterior Windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the <br /> intended weather stripping or other infiltration control measures;_Z.lDampers including exhaust, intake, makeup air, back <br /> draft and flue shall be closed, but not sealed beyond intended infiltration control measures; 3.)_Interior doors, if installed at <br /> the time of the test, shall be open. Access hatches to conditioned crawl spaces and conditioned attics shall be open; <br /> Exterior openings for continuous ventilation systems and heat recovery ventilators shall be closed, sealed; 5.)Heating and <br /> cooling systems, if installed at the time of the test, shall be turned off; and 6. Supply and return registers, if installed at the <br /> time of the test, Shall be fully open. <br /> Results shall be reported as Air Changes per Hour at 50 Pascals(ACH50)and shall be calculated as follows: <br /> 50 ACH =(CFM50 X 60)/Volume <br /> Where:CFM50=Blower door fan at 50 pascal pressure difference <br /> Volume=Conditioned floor area of housing unit x ceiling height. <br />