Product Specifications <br /> MODEL 4WCC4060AI000A OUTDOOR FAN—TYPE SWEPT <br /> RATED Volts/PH/Hz 208-230/1/60 DIA.(IN.) 28.3 <br /> Performance Cooling BTUH(e) 58000 DRIVE/NO.SPEEDS DIRECT/3 <br /> Indoor Airflow(CFM) 1787 CFM @ 0.0 in.w.g.(e) 5500 <br /> Power Input(KW) 4.6 Motor—HP/R.P.M 1/3/825 <br /> EER/SEER(BTU/Watt-Hr.)(b) 12.00/14.00 Volts/Ph/Hz 208-230/1/60 <br /> Sound Power Rating[dB(A)](c) 77.3 F.L.Amps/L.R Amps 1.7/3.5 <br /> PERFORMANCE HEATING INDOOR FAN—TYPE CONSTANTTORQUE ECM <br /> (High Temp.)BTUH 54000 Dia.x Width(in.) 11.87 X 10.68 <br /> Power Input(KW) 4.6 Drive/No.Speeds DIRECT/3 <br /> (Low Temp.)BTUH 34600 CFM @ 0.0 in.w.g.M SEE FAN PERF TABLE <br /> Power Input(KW) 2.80 Motor—HP/R.P.M. 1/1050 <br /> HSPF(BTUH/Watt-Hr) 8.0 Volts/Ph/Hz 208-230/1/60 <br /> POWER CONN.—V/Ph/Hz 208-230/1/60 F.L.Amps 6.9 <br /> Min.Brch.Cir.Ampacity(d) 39.0 FILTER/FURNISHED NO <br /> Fuse Size—Max.(amps) 60 Type Recommended THROWAWAY <br /> Fuse Size—Recmd.(amps) 60 Recmd.Face Area(sq.ft)(9) 5.3 <br /> COMPRESSOR SCROLL REFRIGERANT R-410 <br /> VOLTS/PH/HZ 208-230/1/60 Charge(lbs.) 11.0 <br /> R.L.Amps—L.R.Amps 24.4/144.2 CHARGING SPECIFICATIONS <br /> OUTDOOR COIL—TYPE SPINE FIN Subcooling 6° <br /> Rows/F.P.I 2/24 DIMENSIONS H X D X W <br /> Face Area(sq.ft.) 22.99 Crated(in.) 52 X 47 X 62 <br /> Tube Size(in.) 3/8 WEIGHT <br /> Refrigerant Control EXPANSION VALVE Shipping(lbs.)/Net(lbs.) 594/490 <br /> (a) Rated in accordance with AHRI Standard 210/240. <br /> INDOOR COIL—TYPE PLATE FIN (b) Rated in accordance with D.O.E.test procedure. <br /> Rows/F.P.I 4/15 (c) Sound Power values are not adjusted for AHRI 270-95 tonal <br /> corrections. <br /> Face Area(sq.ft.) 5.0 (d) Calculated in accordance with currently prevailing Nat'l Electrical <br /> Code. <br /> Tube Size(in.) 3/8 (e) Standard Air—Dry Coil—Outdoor. <br /> (f) Standard Air—Dry Coil—Indoor <br /> Refrigeration Control EXPANSION VALVE (9) Filters must be installed in return airstream.Square footages listed <br /> Drain Conn.Size(in.) 3/4 FEMALE NPT are based on 300 f.p.m.face velocity.If permanent filters are used <br /> size per manufacturer's recommendation with a clean resistance of <br /> 0.05"W.C. <br /> 2 4WCC4060A-SU13-1 E-EN <br />
The URL can be used to link to this page
Your browser does not support the video tag.