Laserfiche WebLink
Geotechnical Engineering Evaluation NGA File No.988017 <br /> East Marine View Drive Warehouse May 19,2017 <br /> Everett,Washington Page 4 <br /> dense to very dense sand with some silty zones below the water table, therefore, we consider the <br /> liquefaction potential for this site to be low to moderate. The recommendations provided for site <br /> improvements in the form of stone columns will greatly reduce the liquefaction potential and associated <br /> distress to the structure. <br /> Erosion Hazard <br /> The criteria used for determination of the erosion hazard for affected areas include soil type, slope <br /> gradient, vegetation cover, and groundwater conditions. The erosion sensitivity is related to vegetative <br /> cover and the specific surface soil types, which are related to the underlying geologic soil units. The Soil <br /> Survey of Snohomish County Area, Washington,by the Soil Conservation Service(SCS)was reviewed to <br /> determine the erosion hazard of the on-site soils. The site surface soils were classified using the SCS <br /> classification system as Urban Land. This unit is does not have an erosion hazard listed. In our opinion, <br /> the site soils would have a low to moderate hazard for erosion where exposed. <br /> CONCLUSIONS AND RECOMMENDATIONS <br /> General <br /> It is our opinion that the site is compatible with the planned improvements from a geotechnical <br /> standpoint. Our explorations indicated that the site is underlain by very loose/very soft to very dense/hard <br /> younger alluvial soils. Due to the very loose/soft nature of the upper site soils, we recommend that <br /> support for the proposed structure and improvements to the surficial soils be accomplished with ground <br /> modifications in the form of compacted rock aggregate piers. This type of ground modification includes <br /> augered or vibratory ramming of aggregates within the foundation and slab areas extending through the <br /> upper loose/soft soils. Compacted crushed rock fill is placed within the excavations to further densify <br /> the upper loose/soft soils to provide adequate support for the proposed structures and reducing the <br /> potential for future settlement within the building elements. The building foundations and slab are then <br /> supported directly on the compacted rock aggregate piers. This is further discussed in the Foundations <br /> and the Site Preparations and Grading subsections of this report. <br /> We also recommend that the proposed slabs-on-grade also be supported directly on the compacted rock <br /> aggregate piers. The slabs should be additionally reinforced, and cold joints incorporated in the slab <br /> design to further reduce the effects of differential settlement. In our opinion, slabs supported on <br /> compacted rock aggregate piers should experience minimal cracking and settlement. <br /> NELSON GEOTECHNICAL ASSOCIATES, INC. <br />