Laserfiche WebLink
17 of 34 <br /> MINI <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 7 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 4.2 Pryout Strength(Bond Strength controls) <br /> VcP9 —kcpR AN ec1,Na Wec2,Na Wed,Na Wcp,Na Nba ] ACI 318-14 Eq.(17.5.3.1b) <br /> ANaO <br /> (I) Vcpg >Vaa ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANas =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> cNa =10 da 11t uncr00 ACI 318-14 Eq.(17.4.5.1d) <br /> r 1 <br /> Wec,Na = t 1 + eN <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> cNa <br /> W ed,Na =0.7+0.3 (caa n n) <1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> CNa <br /> W cpNa =MAX(Ca—min CNa) <1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> cac Cac <br /> Nba =X a•tk,c•it•da'hef ACI 318-14 Eq.(17.4.5.2) <br /> Variables <br /> kap aoverhead tk,c,uncr[psi] da[in.] het[in.] Ca,„,,,[in.] t k,c[psi/ <br /> 2 1.000 2,327 0.500 4.000 1,190 <br /> ec9.N[in.] ecz,N[in.] cac[in.] X a <br /> 0.000 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in.2] ANao[in.2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> ect,Na Wec2,Na Wcp,Na Nba[Ib] <br /> 1.000 1.000 1.000 7,475 <br /> Results <br /> Vcpg[Ib] 4)concrete Vcpg[Ib] V.[Ib] <br /> 26,006 0.700 18,204 265 <br /> 5 Combined tension and shear loads <br /> RN Rv Utilization RN,v[%] Status <br /> 0.500 0.021 5/3 32 OK <br /> RNV=IRN+I <= <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 7 <br />