Laserfiche WebLink
5 of 34 <br /> I■4II116011.11I <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 5 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Long Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.3 Concrete Breakout Failure <br /> ANcbg =( co) ec,N wed,N NI N cp,N Nb ACI 318-14 Eq.(17.4.2.1b) <br /> Ncbg>N. ACI 318-14 Table 17.3.1.1 <br /> ANC see ACI 318-14,Section 17.4.2.1,Fig.R 17.4.2.1(b) <br /> ANe, =9 hef ACI 318-14 Eq.(17.4.2.1c) <br /> 1 <br /> ec,N = \1 +2 eN I <1.0 ACI 318-14 Eq.(17.4.2.4) <br /> 3 he <br /> W ed,N =0.7+0.3 c 1.5ha,: <1.0 ACI 318-14 Eq.(17.4.2.5b) <br /> f) <br /> cp,N =MAX(ca=min 1.5hef) 1.0 ACI 318-14 Eq.(17.4.2.7b) <br /> �c�ac cac <br /> Nb =kc A.a yfa hefs ACI 318-14 Eq.(17.4.2.2a) <br /> Variables <br /> he[in.] ec1 N[in.] ec2.N[in.] ca,min[in.] W c,N <br /> 4.000 0.000 0.000 1.000 <br /> cac[in.] kc a fa[psi] <br /> 10.058 17 1.000 4,000 <br /> Calculations <br /> t 7 <br /> ANc[in 2] ANcO[In?] W ecl.N Wec2,N Wed,N Wcp,N Nb[Ib] <br /> 174.00 144.00 1.000 1.000 1.000 1.000 • 8,601 <br /> Results <br /> Ncbg[lb] 4)concrete 4' Ncbq[Ib] N.[Ib] <br /> 10,393 0.650 6,756 1,745 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 6-72 5 <br />