Laserfiche WebLink
14 of 34 <br /> M111.II.T'1 <br /> Hilti PROFIS Engineering 3.0.75 <br /> www.hilti.com <br /> Company: Otak,Inc. Page: 4 <br /> Address: Specifier: <br /> Phone I Fax: I E-Mail: <br /> Design: BRT Shelter Windscreen Retrofit-Short Direction Date: 2/3/2022 <br /> Fastening point: <br /> 3.2 Bond Strength <br /> Nag =(ANaANaO) W ec1,Na Wec2,Na Wed,Na Wcp,Na Nba ACI 318-14 Eq.(17.4.5.1b) <br /> 4> Nag >Nua ACI 318-14 Table 17.3.1.1 <br /> ANa see ACI 318-14,Section 17.4.5.1,Fig.R 17.4.5.1(b) <br /> ANaO =(2 CNa)2 ACI 318-14 Eq.(17.4.5.1c) <br /> cNa =10 da 'V T uncr ACI 318-14 Eq.(17.4.5.1d) <br /> 1100 <br /> 1 <br /> Wec,Na = (1 + eN <1.0 ACI 318-14 Eq.(17.4.5.3) <br /> CNa <br /> W ed,Na =(17+0.3 C�Ca=min) 1.0 ACI 318-14 Eq.(17.4.5.4b) <br /> Na <br /> W cp,Na =MAX(Ca=min, ‘la 1.0 ACI 318-14 Eq.(17.4.5.5b) <br /> Cac Cac <br /> Nba =X a.tk,c•it•da•het ACI 318-14 Eq.(17.4.5.2) <br /> Variables 1 <br /> ti k,c,uncr[psi] da[in.] hef[in.] ca.„,,„[in.] aoverhead Zk,c[psi] <br /> 2,327 0.500 4.000 1.000 1,190 <br /> ec1,N[in.] ec2,N[in.] cac[in.] a <br /> 1.231 0.000 10.058 1.000 <br /> Calculations <br /> CNa[in.] ANa[in 2] Anal)[in•2] W ed,Na <br /> 7.239 364.67 209.62 1.000 <br /> ec1,Na Wec2,Na Wcp,Na Nba[lb] <br /> 0.855 1.000 1.000 7,475 <br /> Results <br /> Nag[Ib] (I)bond 4i Nag[Ib] Nua[Ib] <br /> 11,114 0.650 7,224 3,613 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> 4 <br />