Laserfiche WebLink
Irerracon <br /> HSA ID, Material Description, and HSA Quantity <br /> AHERA Classification Material Location (approximate) <br /> 38: Green and blue carpet, yellow B-1 flooring 500 SF <br /> mastic, paper backing with mastic, <br /> over green vinyl sheeting, black <br /> mastic, tan vinyl floor tile, and black <br /> mastic (M) <br /> 40: Residual vinyl floor sheeting with Hallway behind F-3 to B-2 Quantity included in <br /> paper backing, trace leveling HSA 67 <br /> compound, and black mastic(M) <br /> 41: Black and red vinyl floor sheeting In corner of E-2 50 SF <br /> with paper backing and mastic, and <br /> black asphaltic mastic (M) <br /> 43: Tile pattern vinyl floor sheeting, Flooring in G-6 and G-7 150 SF <br /> clear mastic, tan vinyl sheeting with <br /> paper backing, and black mastic (M) <br /> 45: Silver paint, and black asphaltic Associated with rooftop pipes and 300 LF <br /> material (M) some rooftop mechanical <br /> components <br /> 46: Membrane roof with Styrofoam Roof of main building 22,000 SF <br /> over multilayer asphaltic roofing (M) <br /> 49: White vinyl floor sheeting, clear Flooring in J-7 125 SF <br /> mastic, yellow vinyl floor sheeting <br /> with paper backing and mastic (M) <br /> 51: 9"x9"tan vinyl floor tile and black In carpenter suite 150 SF <br /> mastic <br /> 54: Old electrical boxes with woven In Southwest corner and 12 boxes <br /> wiring Northwest storage area of building <br /> 55: Black mastic (M) Associated with mirrors in G4 3 SF <br /> 56: Black asphaltic material (M) Associated with manhole cover on 5 LF <br /> west side of building <br /> 67: Asbestos-contaminated soil and Hallway F-9 associated with dug 75 cubic feet of debris <br /> debris from trenching activities (M) up trench <br /> 68: Window caulking and glazing Building exterior 4'x4' <br /> compound 4 EA <br /> HSA:material that is uniform in color, texture,general appearance,and construction and application date,M:Miscellaneous <br /> material per AHERA, S:Surfacing material per AHERA, T:Thermal system insulation, LF:linear feet, OD:outer diameter, <br /> SF:square feet <br /> The asbestos-containing window glazing compound was determined to be non-friable as <br /> defined by 40 CFR 61.141 and PSCAA Regulation III, Article 4 at the time of the <br /> assessment and assumes the windows will be removed and disposed of as ACM. The <br /> determination of friability assumed that the roofing materials would be handled in <br /> accordance with WAC 296-62-07712 and W ISHA Regional Directive 23.10. <br /> Regulated Building Materials Assessment <br /> View Ridge Plaza July 10,2020 <br /> Cataylst Capital Holdings,LLC Terracon#81207277 <br /> Page 15 <br />