My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10531 29TH AVE SE 2025-06-24
>
Address Records
>
29TH AVE SE
>
10531
>
10531 29TH AVE SE 2025-06-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2025 9:16:17 AM
Creation date
4/17/2025 11:03:40 AM
Metadata
Fields
Template:
Address Document
Street Name
29TH AVE SE
Street Number
10531
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Report No. 102393982LAX-002 Page 3 of 138 Issued: 11-A r-2016 Report No. 102393982LAX-002 Page 4 of 138 Issued: 11-A r-2016 Noor- <br /> Unirac,p 9 p p 9 p Inc Revised: 5-Od-2022 Unirac, Inc Revised: 5-Od-2022 BLUE RAVEN <br /> 2.0 Product Description 2.0 Product Description SOLAR <br /> Product Photovoltaic M cunting System,Sun Fram e M i;rorail Installation G dde, PUB2022SEP28 M odels Unirac SFM <br /> Brand name Unirac M odel Sim iarity NA <br /> The product covered by this report is the Sun Fram e M cro Rail roof m ounted Photovoltaic <br /> Rack M cunting System.This system is designed to provide bonding and grounding to Fuse Rating: 30A <br /> photovoltaic modules. The m ounting system ern ploys anodized or m it finish alum hum brackets <br /> that are roof m ounted using the slider, outlined in section 4 of this report. There are no rails M odule O Iientation: Portrait or Landscape <br /> within this product,whereas the 3" M cro Rail, Floating Splice, and 9"Attached Splice M adm um M odule Size: 17.98 ft2 <br /> electrically bond the m odules together form hg the path to ground. UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down-Slope <br /> Tested Loads-50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope <br /> The M cro Rails are installed onto the m odule fram a by using a stainless steel bolt anodized Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for M echanical Loading <br /> with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the <br /> m odules to the bracket. The bonding pin of the M cro Rail when bolted and torqued, penetrate Increased size M Ltest: <br /> the anodized coating of the photovoltaic m odule fram a(at bottom flange)to contact the m etal, M a(im urn M odule Size: 22.3 ft2 <br /> creating a bonded connection from module to module. UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down-Slope <br /> Description LG 355S2W-A5 <br /> The grounding of the entire system is intended to be in accordance with the latest edition of the used for Mechanical Loading test. <br /> National Electrical Code, including NEC 250: G Iounding and Bonding, and NEC 690: Solar M cunting configuration: Four m ountings on each long side of panel with the longest span of 24" <br /> Photovoltaic System s or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the UL2703 Design Load Rating:46.9 PSF Downward, 40 PSF Upward, 10 PSF Down-Slope <br /> revision in effect in the jurisdiction in which the project resides.Any local electrical codes m ust LG 335N2W-A5, <br /> be adhered in addition to the national electrical codes. The G rounding Lug is secured to the LG 380S2W-A5 and LG 355S2W-A5 used for used for Mechanical Loading test. <br /> photovoltaic m odule, torqued in accordance with the installation m anual provided in this M cunting configuration: Six m ountings for two m odules used with the m adm um span of 74.5" <br /> docum ent. IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift <br /> O tier optional grounding includes the use of the Enphase UL2703 certified grounding system, Ratings M echanical Load test to add FlashLoc Slider and Trim Assem blies to UL2703 and IEC 61646 <br /> which requires a m him urn of 2 m icro-inverters m ounted to the sam a rail, and using the sam e Certifications, & Increase SFM System UL2703 M odule Size: <br /> engage cable. M adrn urn Module Size: 27.76 ft2 <br /> UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down-Slope <br /> Jinko Eagle 72HM G 5used for Mechanical Loading test. <br /> M cunting configuration: Four m ountings on each long side of panel with the longest span of 24" <br /> M an am um m odule size: 21.86 ft2 <br /> IEC 61646 Test Loads- 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift <br /> SunPower model SPR-A430-CO UM LSD used for Mechanical Loading <br /> Fire Class Resistance Rating: <br /> -Class A for Steep Slope Applications when using Type 1 M odules. Can be installed at any <br /> interstitial gap. Installations m ust include Trim Rail. <br /> -Class A for Steep Slope Applications when using Type 2 M odules. Can be installed at any <br /> interstitial gap. Installations m ust include Trim Rail. <br /> -Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. <br /> This system was evaluated with a 5"gap between the bottom of the m odule and the roof's <br /> surface <br /> See section 7.0 illustractions# 1, 1 a and 1 b for a corn plete list of PV m odules evaluated with <br /> these racking system s <br /> O tier Ratings NA <br /> DRAWING NUMBER: <br /> ED 16.3.15(1-Jul-2022)Maidatory ED 16.3.15(1-Jul-2022)Maidatory S <br /> C <br />
The URL can be used to link to this page
Your browser does not support the video tag.