My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2730 W MARINE VIEW DR 2025-09-03
>
Address Records
>
W MARINE VIEW DR
>
2730
>
2730 W MARINE VIEW DR 2025-09-03
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2025 8:17:57 AM
Creation date
4/18/2025 1:37:24 PM
Metadata
Fields
Template:
Address Document
Street Name
W MARINE VIEW DR
Street Number
2730
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
74
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
S, 0\ ' <br /> ERRA <br /> WALL SYSTEM <br /> CONNECTION CALCULATIONS <br /> Connection is the amount of resistance of the reinforcing has to a pullout failure from the facing units based <br /> on the Tmax applied and the normal load on the units. In an AASHTO LRFD design, creep on the connection may be <br /> applied for frictional and mechanical connections. In NCMA or AASHTO 2002, a frictional failure is based on the <br /> peak connection capacity divided by a factor of safety. For a rupture connection the capacity is the peak load divided <br /> by a creep reduction factor and a factor of safety. <br /> Frictional Connection <br /> Peak Connection = N(ppf)tan(slope) + intercept <br /> Rupture Connection <br /> Connection Capacity=[N(ppf)tan(slope) +intercept]/RFcr <br /> RFcr can be a value obtained from long-term testing or by default could be the creep reduction factor of the <br /> geogrid reinforcing. <br /> Tal_cn =Allowable connection capacity=Tult_cn / FScn <br /> Rc=% coverage <br /> FS=Tal_cn *FScn/Tmax <br /> TABLE OF RESULTS <br /> Elev[ft] Name Tmax[ppf] Rc% N[ppf] Tult_cn Tac[ppf] FS <br /> 26.00 SG350 120 100 535 1108 671 8.36 <br /> 24.00 SG350 214 100 1070 1523 923 6.47 <br /> 22.00 SG350 321 100 1605 1938 1174 5.49 <br /> 20.00 SG350 430 100 2140 2030 1230 4.29 <br /> 18.00 SG350 558 100 2674 2072 1256 3.38 <br /> 16.00 SG350 679 100 3209 2114 1281 2.83 <br /> 14.00 SG350 795 100 3744 2156 1307 2.47 <br /> —. 12.00 SG350 911 100 4279 2198 1332 2.19 <br /> 10.00 SG350 1024 100 4814 2241 1358 1.99 <br /> 8.00 SG350 1135 100 5349 2283 1384 1.83 <br /> 6.00 SG350 1246 100 5884 2315 1403 1.69 <br /> 4.00 SG350 1358 100 6419 2315 1403 1.55 <br /> 2.00 SG350 1467 100 6954 2315 1403 1.43 <br /> Note: Calculations and quantities are for PRELIMINARY ANALYTICAL USE ONLY and MUST NOT be used for final <br /> n or construction without the independent review, verification, and approval by a qualified professional engineer. <br /> UltraWall 5.0.19183 15 <br />
The URL can be used to link to this page
Your browser does not support the video tag.