Laserfiche WebLink
TEMPORARY TRAFFIC CONTROL ZONE ELEMENTS SIGN SPACING=X(FEET)' CITY OF EVERETT TCP REQUIREMENTS 11. CHANNELIZATION DEVICES ARE TO CONFORM TO THE MUTCD(28"RETROREFLECTIVE <br /> 1. SIGNS DEVICES AND SPACING SHALL CONFORM TO THE MUTCD. CONES ARE SUGGESTED). <br /> MINIMUM TAPER LENGTH=L(FEET) FREEWAYS&EXPRESSWAYS 55/70 MPH 1500'± 2. PRIORITY PASSAGE SHALL BE PROVIDED TO EMERGENCY VEHICLES. 12. ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE AT GRADE INTERSECTIONS AND <br /> (OR PER THE MUTCD) 3. NOTIFY TRANSIT 5 DAYS IN ADVANCE OF CARPOOL SPACE/BUS ROUTE&STOP DRIVEWAYS. <br /> POSTED SPEED>45 MPH L=WS(W=LANE WIDTH&S=POSTED SPEED) RURAL HIGHWAYS 60/65 MPH 800'± IMPACTS. 13. STREET SHALL BE COMPLETELY CLEAR TO FULL WIDTH BETWEEN 3PM&9AM <br /> 4. MUTCD DEFINED PROTECTIVE VEHICLE TO BE PLACED IN AN EFFECTIVE LOCATION TO WEEKDAYS,UNLESS EXTENDED HOURS ARE ALLOWED BY WRITTEN PERMISSION <br /> POSTED SPEED<45 MPH L=(WS')/60(W=LANE WIDTH&S=POSTED SPEED) RURAL ROADS 45/55 MPH 500'± PROTECT WORKERS(RECOMMENDED). FROM LOCAL DOT AND TC. <br /> 5. MAINTAIN 1 V VEHICLE TRAVEL LANE WIDTH AT ALL TIMES. 14. LAW ENFORCEMENT OFFICERS ARE TO BE USED IN LIEU OF FLAGGERS TO CONTROL <br /> MINIMUM LONGITUDINAL BUFFER SPACE=B(FEET) RURAL ROADS&URBAN ARTERIALS 35/40 MPH 350'± 6. MAINTAIN 4'OF UNAFFECTED PEDESTRIAN TRAVEL LANE ON OPEN SIDEWALKS. INTERSECTION TRAFFIC.MULTIPLE OFFICERS ARE TO BE USED FOR INTERSECTIONS <br /> POSTED SPEED MPH 25 30 35 40 45 50 55 60 65N 7. MAINTAIN V LANDING BEHIND OPEN ADA RAMPS AT ALL TIMES WHEN WORKING IN ON HIGH IMPACT STREETS. <br /> (MPH) RURAL ROADS,URBAN ARTERIALS 25/30 MPH 200'±" THEIR VICINITY. 15. "NO PARKING"SIGNS TO BE PLACED ON CURB SPACE,INCLUDING PAID PARKING. <br /> LENGTH(FEET) 155 200 250 305 360 425 - _ _ RESIDENTIAL&BUSINESS DISTRICTS 8. FLAGGERS SHALL CONDUCT PEDESTRIAN TRAFFIC CONTROL AND ARE TO MAINTAIN 16. CONTRACTOR IS TO COORDINATE/FACILITATE DRIVEWAY/LOADING ZONE ACCESS. <br /> URBAN STREETS 25 MPH or LESS 100'±" OPEN SIDEWALKS AND ADA RAMPS. 17. PROTECTIVE VEHICLE SHALL MAINTAIN 500'-1000'OF SIGHT DISTANCE TO <br /> ROLL-AHEAD DISTANCE=R(FEET) 9. IF OPEN SIDEWALKS AND ADA RAMPS CANNOT BE MAINTAINED,CONTRACTOR IS TO APPROACHING TRAFFIC. <br /> ALL SIGNS ARE 48"x 48"BLACK ON ORANGE UNLESS OTHERWISE DESIGNATED. PROVIDE A PATH FOR PEDESTRIAN TRAVEL THROUGH/AROUND STAGING AREA AS 18. CONTACT REGIONAL TRAFFIC OFFICE STAFF FOR ASSISTANCE WITH SPECIFIC IN LANE <br /> R=30'MINIMUM-100'MAXIMUM DEFINED BY THE MUTCD. OPERATIONS SUCH AS STRIPING,FOG SEAL,ETC.THAT REQUIRE ADDITIONAL PLANS <br /> MAXIMUM CHANNELIZING DEVICE SPACING(FEET) ALL SPACING MAY BE ADJUSTED TO ACCOMMODATE INTERCHANGE 10. ALL ADVANCED WARNING SIGNS SHALL BE MINIMUM 48"X48"BLACK ON FLUORESCENT AND DETAILS. <br /> RAMPS,AT-GRADE INTERSECTIONS,AND DRIVEWAYS. ORANGE UNLESS SPECIFIED OTHERWISE. <br /> POSTED SPEED(MPH) 25/30 35/45 50/70 ADVANCED WARNING SIGNS IF FEASIBLE. <br /> TAPER 20 30 40 1) As per TCP provided, City of Everett design standard 702 and MUTCD standards as applicable. <br /> TANGENT 40 60 80 2) "No Parking, TOW AWAY" signs must be placed 96 hours in advance of any work. Contact Everett Police Department, Parking Enforcement at 425-257-7493 <br /> after the signs are up. <br /> APPROVED AS NOTED <br /> ���� By JWISDOM at 6:41:41 AM,4/28/2020 <br /> 3829 HOYT AVE X W 0 � <br /> 35 3909 HOYT V <br /> PARCEL NO. PARCEL NO. - <br /> 00411300301500 5- 00411300600100 <br /> o ° <br /> x x x <br /> W1-4L W5-1 W20-1 <br /> 0 <br /> e R <br /> 50'-100' • e EA 2 <br /> e ¢ CO <br /> — I • ° e ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■■ e e e e s a s <br /> 50'-100' -{ 16-7L <br /> HOYTAVE uz �50'-100' (9) <br /> � <br /> 11'MIN <br /> M — <br /> o O <br /> X O <br /> It 1 3909 RUCKER AVE <br /> 33 2 FF// ooa Roo 00 00 <br /> SCOPE OF WORK: VERIZON CONTACT: <br /> USE WORK AREA TO PLACE VAULT, DAVID LACOMBE <br /> BORE/TRENCH CONDUIT&PULL FIBER CABLE 3245 158TH AVE SE <br /> THROUGH. BELLEVUE,WA98008 <br /> C.206.305.5366 <br /> STREET USE PERMIT#:TBD BY CITY DAVID.LACOMBE@ONE.VERIZON.COM <br /> HOURS:TBD BY CITY <br /> LEGEND SIGN LEGEND • 3 BUILT <br /> 2 REEVIVI SION# 1 <br /> ■ ■ ■ CHANNELIZING DEVICES 1 4/s/2o 5R 8A ORIGINAL <br /> HIGH VISIBILITY WARNING BEACON Know what's below. NO. DATE ENGINEER DRAFTER COMMENT <br /> PARKING Cal before you dig. <br /> (REQUIRED) ROAD ROAD FROM 0 verizon� M <br /> W20-1 SIGN LOCATION AND NARROWS 10 0 <br /> F► IDENTIFICATION NUMBER AHEAD TOW AWAY AREA r <br /> R706-684-saa4 VERIZON ENGINEER:DAVID LACOMBE <br /> an0xe zp"xx „ <br /> -T39 W16-7L ENGINEERING FIRM:MGC TECHNICAL CONSULTING INC. <br /> W20-1 W5-1 W1-4R W1-4L <br /> 48"X48" 48"X48" 48"X 48" qg X qg 36"x24" 12"x36" PROJECT NAME:TULLY'S EVERETT-WAEVT-002 <br /> LOCATION:3909 HOYT AVE <br /> SHORT-TERM STATIONARY WORK ZONE-LANE RED UCTIONAND PARKING CLOSURE (FOR URBAN STREET) 0 10' 20' W. EVERETT,WA 98201 <br /> PERMIT NUMBER: <br /> TRAFFIC CONTROL PLAN #3 - USE SET-UP WHERE APPLICABLE ALONG HOYT AVE (NORTH BOUND LANE) DRAWING NAME:VERIZON-VERIZON WIRELESS-TULLY'S EVERETT-WAEVT-002-TCPs.dwg <br /> SCALE:1"=30' CONFIDENTIAL/PROPRIETARY SHEET: 3 OF 3 <br />