Laserfiche WebLink
CIRCUITS <br />EMERGENCY NORMAL <br />N/A <br />a <br />m <br />9## <br />CIRCUITS <br />EMERGENCY <br />NORMAL <br />ev <br />0-0 <br />N/A <br />N/A <br />N/A <br />M 0 <br />N/A <br />a a <br />N/A <br />a a <br />N/A <br />4- <br />N/A <br />V <br />N/A <br />o <br />N/A <br />V <br />L b U6, <br />_A L'ffV a. <br />ROM <br />LOWER-CASE LETTER NEAR FIXTURE DENOTES SWITCH LEG, TYP <br />FIXTURE ON NORMAL AND EMERGENCY CIRCUITS <br />FIXTURE IDENTIFICATION, SEE LIGHTING FIXTURE SCHEDULE <br />LIGHTING STANDARD: FIXTURES, POLE, AND BASE <br />LAMP POST <br />SITE LIGHTING BOLLARD <br />IN -GROUND FIXTURE <br />AIMED IN -GROUND FIXTURE <br />EXTERIOR RECESSED ACCENT FIXTURE <br />EXTERIOR SURFACE MOUNTED ACCENT FIXTURE <br />EXTERIOR SEMI -RECESSED ACCENT FIXTURE <br />EXTERIOR DOWNLIGHT FIXTURE <br />EXTERIOR MONOPOINT FIXTURE <br />a LOWER-CASE LETTER NEAR SWITCH DENOTES CIRCUIT <br />CONTROLLED (TYP) <br />PC PC PHOTOCELL CONTROL <br />PS PHOTO SENSOR CONTROL <br />RELAY, NEC CLASS II <br />w_ <br />3 <br />s, <br />m <br />`2 <br />co <br />0 <br />cV <br />cV <br />a <br />co <br />0 <br />0 <br />w <br />m <br />I <br />0 <br />M <br />co <br />co <br />m <br />O <br />N <br />/ <br />W <br />U <br />N <br />PANELBOARDS <br />dra 208V SYSTEM PANELBOARD <br />99-3 480V SYSTEM PANELBOARD <br />ELECTRICAL RISER <br />FEEDER SIZE IDENTIFICATION <br /><= AVAILABLE FAULT CURRENT IDENTIFICATION <br />0 a ARRESTOR, SURGE <br />®® <br />ARRESTOR, LIGHTNING <br />�b <br />a <br />AUTOMATIC TRANSFER SWITCH <br />BUS SPACE <br />SPACE <br />BUS DUCT <br />[A 1:1 <br />BUSWAY END TAP BOX <br />CABLE TO BUS CONNECTION <br />I <br />CAPACITOR <br />I I <br />CONTACT, NORMALLY OPEN AND NORMALLY CLOSED <br />s"'d <br />CIRCUIT BREAKER <br />CIRCUIT BREAKER, DRAWOUT <br />-ZZ- J � <br />CIRCUIT BREAKER, DRAWOUT, MEDIUM VOLTAGE <br />GF <br />GFI <br />CIRCUIT BREAKER, <br />GF <br />WITH DRAWOUT <br />CIRCUIT BREAKER, GA <br />" & V <br />CIRCUIT BREAKER, MAGNETIC OVERLOAD <br />CIRCUIT BREAKER, NETWORK PROTECTOR <br />CIRCUIT BREAKER, THERMAL OVERLOAD <br />EEt-PFUSE OR CURRENT LIMITER <br />FUSE (ISOLATING) <br />a <br />a� <br />FUSED SWITCH <br />�- <br />GROUND <br />PUSHBUTTON <br />0 SPLICE <br />O STRESS RELIEF, MEDIUM VOLTAGE <br />a� SWITCH, 2-POLE <br />H <br />a <br />A <br />a <br />SWITCH, 3-POLE <br />0 <br />THERMAL ELEMENT <br />M TRANSFORMER <br />(� <br />TRANSFORMER, CURRENT <br />TRANSFORMER, ELECTROSTATICALLY SHIELDED, MAGNETIC CORE <br />SHOWN <br />nr-m <br />TRANSFORMER, MAGNETIC CORE SHOWN <br />F <br />TRANSFORMER, SHIELDED, MAGNETIC CORE SHOWN <br />�rw�nJ <br />0 <br />AMMETER <br />UC <br />CONTACTOR <br />OG <br />ENGINE -GENERATOR <br />K� <br />KEY INTERLOCK <br />METER <br />PM <br />POWER METER <br />OR <br />RELAY <br />G <br />RELAY, GFI <br />SURGE PROTECTIVE DEVICE <br />OVOLTMETER <br />WHM <br />WATT HOUR METER <br />CIRCUITS <br />- RACEWAY CONCEALED IN CEILING OR WALL. HASH MARKS <br />INDICATE NUMBER OF WIRES. #12 AWG WIRE UNLESS OTHERWISE <br />NOTED. EXPOSED RACEWAY IS ALLOWED ONLY WHERE NOTED. <br />HOT (SHORT HASH MARK) <br />- NEUTRAL (LONG HASH MARK) <br />GROUND WIRE (JOGGED HASH MARK) <br />EXISTING RACEWAY (IF HASH MARKS ARE SHOWN, PULL NEW <br />CONDUCTORS) <br />RACEWAY BELOW SLAB OR UNDERGROUND <br />RACEWAY UP <br />RACEWAY DOWN <br />RACEWAY STUB -OUT WITH BUSHING <br />— CIRCUIT CONTINUATION <br />HOME RUN TO PANEL OR LOCATION NOTED <br />JUNCTION BOX <br />PB PULL BOX <br />OR DEFINITION <br />FLAG NOTE <br />® REVISION IDENTIFICATION <br />- EQUIPMENT IDENTIFICATION <br /># EQUIPMENT IDENTIFICATION <br />Det# DETAIL REFERENCE <br />Sheet# <br />Det# DETAIL REFERENCE W/ORIGINATING SHEET REFERENCE <br />PlanSheet# DetSheet# <br />Sec# SECTION REFERENCE <br />Sheet# <br />Sec# SECTION REFERENCE W/ORIGINATING SHEET REFERENCE <br />PlanSheet# DetSheet# <br />1 <br />BeY# ELEVATION REFERENCE <br />Sheet# <br />aPROJECT NORTH REFERENCE <br />True <br />Natl <br />a D\v PROJECT NORTH REFERENCE W/TRUE NORTH REFERENCE <br />NEW WORK <br />EXISTING <br />----- FUTURE <br />j xxxx REMOVE EXISTING ELECTRICAL EQUIPMENT <br />LIGHTING FIXTURE SCHEDULE <br />E0.00 SYMBOLS, ABBREVIATIONS, DRAWING LIST <br />E1.20 SITE LIGHTING PLAN - NORTH <br />E1.21 SITE LIGHTING PLAN - SOUTH <br />LAMP <br />INPUT <br /># <br />CODE <br />WATTS <br />VOLT* <br />ALTERNATE <br />TYPE <br />DESCRIPTION <br />MANUFACTURER <br />MANUFACTURERS <br />COMMENTS <br />L16 <br />POLE MOUNTED SINGLE -HEAD <br />COOPER INVUE VXM <br />AS APPROVED <br />6 <br />21 LED <br />146 <br />UNV <br />LED CUT-OFF LUMINAIRE, <br />SERIES <br />LIGHT BARS <br />NOMINAL 22.5" X 16" X 8", WITH <br />SPECULAR ALZAK REFLECTOR. <br />TYPE III LIGHT DISTRIBUTION. <br />PHILIPS ADVANCE DIMMING <br />BALLAST FOR MINIMUM 150 <br />WATTS. 20' HIGH, ROUND, <br />TAPERED, ALUMINUM POLE. <br />MANUFACTURER'S STANDARD <br />FINISH AS SELECTED BY <br />ARCHITECT. <br />L10A <br />SIMILAR TO L10 EXCEPT WITH <br />COOPER INVUE VXM <br />AS APPROVED <br />6 <br />21 LED <br />292 <br />UNV <br />DUAL HEADS AND TYPE IV LIGHT <br />SERIES <br />LIGHT BARS <br />DISTRIBUTION. <br />PER <br />FIXTURE <br />L10B <br />SIMILAR TO L10 EXCEPT <br />COOPER INVUE VXM <br />AS APPROVED <br />6 <br />21 LED <br />146 <br />UNV <br />MOUNTED ON EXISTING POLE. <br />SERIES <br />LIGHT BARS <br />PER <br />FIXTURE <br />L10C <br />SIMILAR TO L10 EXCEPT <br />COOPER INVUE VXM <br />AS APPROVED <br />6 <br />21 LED <br />146 <br />UNV <br />MOUNTED ON 12' HIGH, ROUND, <br />SERIES <br />LIGHT BARS <br />TAPERED, ALUMINUM POLE. <br />PER <br />FIXTURE <br />GENERALNOTES <br />1. COMPLY WITH THE NATIONAL ELECTRICAL CODE AS ADOPTED AND AMENDED BY THE LOCAL <br />AUTHORITY HAVING JURISDICTION. <br />2. FOR LIGHTING CONTROLS WHICH INCLUDE DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS, <br />AUTOMATIC SHUT-OFF CONTROLS, OCCUPANCY SENSORS, OR AUTOMATIC TIME SWITCHES THE <br />LIGHTING CONTROLS SHALL BE TESTED TO ENSURE THAT CONTROL DEVICES, COMPONENTS, <br />EQUIPMENT, AND SYSTEMS ARE CALIBRATED, ADJUSTED, AND OPERATE IN ACCORDANCE WITH <br />PROJECT PLANS AND SPECIFICATIONS. SEQUENCE OF OPERATION SHALL ALSO BE FUNCTIONALLY <br />TESTED TO ENSURE IT IS OPERATING IN ACCORDANCE WITH PROJECT PLANS AND SPECIFICATIONS. A <br />COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE <br />OWNER. <br />a R .o <br />ABV <br />ABOVE <br />MCC <br />MOTOR CONTROL CENTER <br />AC <br />3" ABOVE COUNTER BACKSPLASH <br />MDF <br />MAIN DISTRIBUTION FRAME/FACILITY <br />ACH <br />ABOVE COUNTER HEIGHT <br />MH <br />MANHOLE <br />AFF <br />ABOVE FINISHED FLOOR <br />MM <br />MUL11MODE <br />AG <br />ABOVE GRADE <br />MTD <br />MOUNTED <br />A,AMP <br />AMPERE <br />MW <br />MICROWAVE <br />A/V <br />AUDIO/VISUAL <br />N <br />NEUTRAL <br />ATS <br />AUTOMATIC TRANSFER SWITCH <br />NIC <br />NOT IN CONTRACT <br />AWG <br />AMERICAN WIRE CAUGE <br />OPER <br />OPERATER/OPERABLE <br />CATV <br />COMMUNITY ACCESS TELEVISION <br />OP01 <br />OWNER PROVIDED OWNER INSTALLED <br />CB <br />CIRCUIT BREAKER <br />PB <br />PULLBOX <br />CCTV <br />CLOSED CIRCUIT TELEVISION <br />PNL <br />PANEL, PANELBOARD <br />CKT <br />CIRCUIT <br />POS <br />POSITION/POINT OF SALE <br />CLG <br />CEILING <br />PR <br />PAIR <br />CM <br />CEILING MOUNTED <br />PTS <br />PNEUMATIC TUBE STATION <br />COMM <br />COMMUNICATIONS <br />R <br />RACEWAY <br />C <br />CONDUIT <br />RO <br />RACEWAY ONLY <br />CO <br />CONDUIT ONLY <br />RECEPT <br />RECEPTACLE <br />CTRL <br />CONTROL <br />REF <br />REFRIGERATOR <br />CU <br />COPPER <br />SLV <br />SLEEVE <br />D <br />DATA <br />SM <br />SINGLEMODE <br />DED <br />DEDICATED <br />SPECS <br />SPECIFICATIONS <br />DEV <br />DEVICE <br />SW <br />SWITCH <br />DN <br />DOWN <br />SWBD <br />SWITCHBOARD <br />DW <br />DISHWASHER <br />TELECOM <br />TELECOMMUNICATIONS <br />EWC <br />ELECTRIC WATER COOLER <br />TGB <br />TELECOMMUNICATIONS GROUNDING <br />FA <br />FIRE ALARM <br />BUSBAR <br />FB <br />FLOOR BOX <br />TMGB <br />TELECOMMUNICATIONS MAIN <br />FBOIC <br />FURNISHED BY OTHERS, INSTALLED <br />GROUNDING BUSBAR <br />BY CONTRACTOR <br />TSER <br />TELECOMMUNICATIONS SERVICE <br />A <br />FILM ILLUMINATOR <br />ENTRANCE ROOM <br />FO <br />FIBER OPTIC(AL) <br />TV <br />TELEVISION <br />FOC <br />FACE OF COLUMN <br />TYP <br />TYPICAL <br />G,GND <br />GROUND <br />OF <br />UNDER FLOOR <br />GD <br />GARBAGE DISPOSAL <br />UG <br />UNDER GROUND <br />GFI,GFCI <br />GROUND FAULT CIRCUIT <br />UON <br />UNLESS OTHERWISE NOTED <br />INTERRUPTER <br />UTP <br />UNSHIELDED TWISTED PAIR <br />HH <br />HAND HOLE <br />V <br />VOLT OR VOICE <br />HP <br />HORSEPOWER <br />VEL <br />VERIFY EXACT LOCATION <br />IDF <br />INTERMEDIATE DISTRIBUTION <br />W <br />WIRE, WATT, OR WALLPHONE <br />FRAME/FACILITY <br />WAP <br />WIRELESS ACCESS POINT <br />IH <br />INSTA-HOT WATER DISPENSER <br />WI' <br />WEATHERPROOF <br />J-BOX <br />JUNCTION BOX <br />XFMR <br />TRANSFORMER <br />MAG <br />MAGNETIC <br />0 <br />PHASE <br />PORTLAND <br />SEATTLE <br />LOS ANGELES <br />WASHINGTON DC <br />NEW YORK <br />925 Fourth Avenue <br />Suite 2400 <br />Seattle, WA 98104 <br />T 206 623 9414 <br />F 206 623 7828 <br />www.zgf.com <br />Consultants <br />CIVIL ENGINEER <br />Magnusson Klemencic Associates <br />1301 Fifth Avenue, Suite 3200 <br />Seattle, WA 98101-2699 <br />T 000-000-0000 <br />LANDSCAPE ARCHITECT <br />Site Workshop <br />222 Eturia Street <br />Seattle, WA 98109 <br />T 206-285-3026 <br />ELECTRICAL ENGINEER <br />STANTEC CONSULTING SERVICES <br />4100194th Street, Suite 400 <br />Lynwood, WA 98036-4613 <br />T 206-667-0553 <br />Revisions <br />NORTH SITE <br />} <br />Regional Medical Center <br />Everett <br />1700 13TH STREET <br />EVERETT, WA 98201 <br />Drawing <br />DRAWING LI <br />Date: <br />04/15/2016 <br />Job No: <br />S23257 <br />Drawn By: <br />JTW <br />Checked By: <br />MDJ <br />Drawing No. <br />1 11 <br />J <br />