. I SE 1 /4, NE 1 /4 SEC 1 1 , T. 28 N., R. 4 E., W.M.
<br /> I
<br /> 1
<br /> �, EROSION CONTROL NOTES:
<br /> CB 2271 TYPE I
<br /> TEMPORARY BENCHMARK , GE=2.CO
<br /> O CATCH BASIN INLET PROTECTION PER WSDOT
<br /> NORTHERLY FLANGE BOLT ON FIRE HYDRANT I IE 12'CONC 5=569.50
<br /> 110, IN THE NE DLIAD OF THE INTERSECTION OF I STD. PLAN 1-40.20-00.
<br /> 75TH ST SW&SEAWAY BLVD CB 2033 TYPE I
<br /> ELEV=575.04 I GE=573.37 ® CONSTRUCTION ENTRANCE ROCK PAD PER
<br /> ,e ` IE 12'HDPE SW567.073 C.O.E. STD. PLAN 201.
<br /> IE 12.CONC N=567.07
<br /> _ IE 12'CONC E=567.07
<br /> /"2'BRA55 DISK WITH PUNCH, O TEMPORARY SILT FENCE PER C.O.E. STD. PLAN
<br /> IN CASE,0.T N X 0.4'W, CONC O 2EDIM NTTD. PLANS
<br /> DOWN 0.3' �"-- WgCK �\
<br /> �_ •
<br /> CB 2037 TYPE I 4 217-219 SEE DWG SPD1.
<br /> C.O.E.E
<br /> GE=572.79
<br /> O+00E 12"CONC NW=56J.03 O
<br /> MONUMENT LID --"�` IE 12.CONC 5E=567.03 S INTERCEPTOR SWALE PER C.O.E. STD. PLAN
<br /> UNABLE . OPEN 204.
<br /> Si 'AL `\\��I © ROCK CHECK DAM PER C.O.E. STD. PLAN 206.
<br /> •\ O TEMPORARY 12- DUCTILE IRON CULVERT.
<br /> 1 oik ��\ SCALE O TEMPORARY QUARRY SPALL SPILLWAY.
<br /> .574_ 15' s? `------674-__ __ _-- •`•�\ 20 0 FEET 20 40 SITE PREPARATION/DEMO NOTES:
<br /> v CURB&GU?TER,.
<br /> TO SW r' �-{ m G k' \ \\ ® SAWCUT EXISTING ASPHALT PAVEMENT.
<br /> CB 2024 TYPE I O` \ °SIGAL AHEAD' wno '� `\ 21 REMOVE EXISTING CURB OR CURB AND GUTTER.
<br /> ^��� Cll'OF EVERER PROPERn' RAPED SIGNAL AH IGN \
<br /> GE=575.37 ,`.ti. -, \��.,;�. \
<br /> IE 12"HOPE S=571.42 = D'K / NO TRESPASSING -:US STOP'
<br /> IE 12"HOPE NE-5T.40 0, UNAUTHORIZED VEHICIFS IMP G \\ ® REMOVE EXISTING ASPHALT PAVEMENT OR SIDEWALK.
<br /> 0 • GENERAL NOTES:
<br /> I yi- ? G!1 \\ © RELOCATE EXISTING STREET LGHT LUMINAIRE.
<br /> ` I qT m. ® \ 1. THE AREA WITHIN THE SITE BOUNDARY UNES
<br /> y �. •� , t! t `� 0' 0 \\ cE=s72.43 00 TYPE I WILL BE CLEARED k GRUBBED INCLUDING THE 10' Q REMOVE EXISTING TREE(S).
<br /> / _ _ j _ `_ ♦ \ IE 12'cDNc Nw=5sa63 EASEMENT SOUTH OF THE SOUTH PROPERTY LINE
<br /> k-- � ,� _ _ \ IE 12°CONC 5E=568.63 AND ON THE PUD SUBSTATION PROPERTY. © PROTECT EXISTING PUD ELECTRICAL nT51tM5 AND
<br /> i i L 1 11 .. - 'ST3_ �/'- `V POWER POLE.
<br /> • LEGEND:
<br /> S" i r \ ©6 EXISTING PUD DUCT BANK TO REMAIN. PROTECT
<br /> P 1 0--'.. o-- ,'0*
<br /> ; �� \ DURING CONSTRUCTION.
<br /> � S�
<br /> ��,a� PAVEMENT REMOVAL
<br /> _ / `�` I rr a ,4��17 ��` `��' ,..�`` O�\ \\ INCLUDING SIDEWALKS
<br /> \/(\ ,�-- - -;� `�` \ ® ADJUST EXISTING J-BOX/HANDHOLE TO GRADE.
<br /> • y cr+^ I ---r.5„ ---=r rr ,r/ , !••,, e \ `1`� ` - \ \\\ SLOPE PROTECTION MULCH ® REMOVE EXISTING SIGN.
<br /> .! / It I I ( • ,j-: -1-,-----.- '�. :`\ \--- \ ® NOT USED.
<br /> 1_i ' QI ,� �, ` 0 \ \ \\\ m INLET PROTECTION O PROTECT EXISTING PEDESTRIAN PUSHBUTTON
<br /> ©� - r / Ifaa 1 i ♦� �� -39tIH V 1M SILT FENCE ASSEMBLY.
<br /> m o / �` 1 �, 1, ` \`I I r s• ♦\ f�� ``' �� Cc,7rta!UD=s7z.71 \\ EXISTING FEATURE TO BE REMOVED 31 PROTECT EXISTING LUMINAIRE.
<br /> ` I �I m� i i �� i Ate' N• r `.,•� te © � V -� - - - INTERCEPTOR SWALE
<br /> III -GORPO•' E&CONPINu\ I I I I I �, s Ns C � \ © PROTECT EXISTING POWER STRUCTURES.
<br /> E)UCATIO GENTS" ; I ' I ' •
<br /> I, �`` a ) �I '� rr ,•e `,�;• • \ • \ \ ® ROCK CHECKDAM
<br /> in ® i 1 i 11 1 ICI \ �'I �� 11 i' %' ,•4. i� \\ �` `\ O SG1 SSEE IG4� PLANS FOR SIGNAL REMOVAL DWG
<br /> `' I 1 1 " I 'I 1, r PUD SIGN @ '�` 1,S \ �`` ` !y __ \\ O NOT USED.
<br /> b 10 1` '1 , , ' ( *HELP KEEP �/ f� ,rr 'O:` .:`V �\ �:\,.� \\ A
<br /> �! •�1 I 1 ` m - � I FACILITY SAFE ?r • / `� S`\\\ \ \ I ® REMOVE EXISTING DRAINAGE STRUCTURE.
<br /> V ! i I I I \ 7r \ \ CB 2528 TYPE
<br /> c
<br /> I O \ I i II 'I r ` \ .\ C�� \ \ EE 1271.50
<br /> CONC NW=566.20 O REMOVE EXISTING POWER STRUCTURE, BY OTHERS.
<br /> I \ ` II `/ ` ; I I rr ry S. \ IE 12'LONG 5E=566.09
<br /> ',I, \ 1 L'� I 'I 'I i C!'� f, �`��\ '\ \ ® RELOCATE EXISTING J-BOX OR POWER STRUCTURE.
<br /> �, Q ©. I 1 i r • i ♦ �' \ N. F, S \ \ MOVE CONDUIT AND REPLACE ALL WIRES TO NEW
<br /> " W �'I � 1 1 I I i i IN I,` ��`�,` � V`AV�2-, 4 , \V LOCATION.
<br /> .� - I I I •
<br /> `� `.\ \ ® ADJUST EXISTING WATER STRUCTURE TO FINISHED
<br /> ` 1 F 1 1 I I r f, ```\`�`, \� mA\ `�; -- '�j\ GRADE. BY OTHERS.
<br /> r' a I I I r �i O ,• -`�' \ �'": ` \ O ADJUST EXISTING POWER STRUCTURE TO FINISHED
<br /> i
<br /> ° I t ��\` , - i i 1 i si ` ` `•�` A GRADE, BY OTHERS.
<br /> , \\\\..
<br /> n. 1 1 1 iI I cRtr �i` `♦•�,��\:A � \\ 40
<br /> o ml D ! I 1 i 1 / ``�\` `O \`,`` \ PROTECT EXISTING SIGN.
<br /> r rI ` '474 \ • 41 NOT USED.
<br /> 1 I I ' I ' ,,;\ i i i i �� f, ``\ `C``\ I`, ; `\ \ \
<br /> t a I I m1' 1 I'I I II rr I ! ♦,i \ �``'\\�,`�\` 'Sa`� l \\ ® RELOCATE EXISTING WATER VALVE BEHIND PROPOSED
<br /> `? I a i r i r i ,f ,' ```\ � `.V. a\ 1 \ SIDEWALK.
<br /> r 1 co I I i , r�r r i / r \ y",-, > A
<br /> r m I \ 1 i ( i r r\�i ., ♦, ```��\`\ ```\` �.\;\$r,- \ O RELOCATE EXISTING WATER METER BEHIND PROPOSED
<br /> ` I i 1 r i Ir ♦� f, ``\`� ` \\\ �.\ - \ SIDEWALK AND EXTEND WATER SERVICE, BY OTHERS.
<br /> 1 1E ` 1 r iI .� •,♦ ``�`�`�`� ``� �` 9 \ \\ ADJUST EXISTING GAS VALVE TO FINISHED GRADE, BY
<br /> u 111111 Ls 1 , I. 1 II i i i I ' ♦! \\``\ \`\``\\ `� ''.by\\\ (fs \ O OTHERS.
<br /> E ,, i i i I i i i I •, \` ``�`�`\\`` \ - I \\ RELOCATE EXISTING POWER STRUCTURE BEHIND
<br /> 4 ' ',\ -\ i i i i i i ' I • \ �```�` \' \` 00 , \ O PROPOSED SIDEWALK, BY OTHERS.
<br /> ai \I i , I II ♦ S 4 \
<br /> 1 I 1 1 , i i ,♦ \' � `` � \\. \ rr \\ REMOVE STRIPING.
<br /> P I I I 1 , ` \
<br /> ry % I n I. I vh 1 i i i i i p �```\ ` `\ \ t'� , �� \ O PROTECT EXISTING TREE.
<br /> IiiO '\ si \\ \ ' 1 O 1 •
<br /> •� \ \ •t \. "F sios °NARBECK aka N° \ 47
<br /> "�`. ,,.j 1 I ' II �♦ • \ •, ` J \```\`v, \ .t 10' \\ \ 'ADOPT A 4 EY
<br /> d �- 9' , ' -.. _. 1 DT Loll mw �` ` • P° A`
<br /> MATC H LI N E SEE SHEET S P2 CALL 2 BUSINESS DAYS BEFORE YOU DIG All
<br /> E 1 800 424 5555 V
<br /> x UTILITIES UNDERGROUND LOCATION CENTER I
<br /> U
<br /> E COMMUNITY TRANSIT Drawing No.
<br /> Pe rteet Drawn Date �.�F
<br /> o��o 0 75%SUBMITTAL MMc 9/27/16 SP 1
<br /> DBefgned "°"� SEAWAY TRANSIT CENTER
<br /> 425-252-770011-800615-9900 communitytran NOT FOR MN 9/27/16 1'-20'
<br /> 2707 Colb Avenue,Suite 900 CONSTRUCTION Checked By Vert SITE PREPARATION & Sheet No.
<br /> Pr - a BC 9/27/16 /
<br /> No. Date Revision By APpr. Everett,Washington 98201 APPraved By Project Name. EROSION CONTROL PLAN r Total
<br /> 20110155.023
<br />
|