Laserfiche WebLink
. I SE 1 /4, NE 1 /4 SEC 1 1 , T. 28 N., R. 4 E., W.M. <br /> I <br /> 1 <br /> �, EROSION CONTROL NOTES: <br /> CB 2271 TYPE I <br /> TEMPORARY BENCHMARK , GE=2.CO <br /> O CATCH BASIN INLET PROTECTION PER WSDOT <br /> NORTHERLY FLANGE BOLT ON FIRE HYDRANT I IE 12'CONC 5=569.50 <br /> 110, IN THE NE DLIAD OF THE INTERSECTION OF I STD. PLAN 1-40.20-00. <br /> 75TH ST SW&SEAWAY BLVD CB 2033 TYPE I <br /> ELEV=575.04 I GE=573.37 ® CONSTRUCTION ENTRANCE ROCK PAD PER <br /> ,e ` IE 12'HDPE SW567.073 C.O.E. STD. PLAN 201. <br /> IE 12.CONC N=567.07 <br /> _ IE 12'CONC E=567.07 <br /> /"2'BRA55 DISK WITH PUNCH, O TEMPORARY SILT FENCE PER C.O.E. STD. PLAN <br /> IN CASE,0.T N X 0.4'W, CONC O 2EDIM NTTD. PLANS <br /> DOWN 0.3' �"-- WgCK �\ <br /> �_ • <br /> CB 2037 TYPE I 4 217-219 SEE DWG SPD1. <br /> C.O.E.E <br /> GE=572.79 <br /> O+00E 12"CONC NW=56J.03 O <br /> MONUMENT LID --"�` IE 12.CONC 5E=567.03 S INTERCEPTOR SWALE PER C.O.E. STD. PLAN <br /> UNABLE . OPEN 204. <br /> Si 'AL `\\��I © ROCK CHECK DAM PER C.O.E. STD. PLAN 206. <br /> •\ O TEMPORARY 12- DUCTILE IRON CULVERT. <br /> 1 oik ��\ SCALE O TEMPORARY QUARRY SPALL SPILLWAY. <br /> .574_ 15' s? `------674-__ __ _-- •`•�\ 20 0 FEET 20 40 SITE PREPARATION/DEMO NOTES: <br /> v CURB&GU?TER,. <br /> TO SW r' �-{ m G k' \ \\ ® SAWCUT EXISTING ASPHALT PAVEMENT. <br /> CB 2024 TYPE I O` \ °SIGAL AHEAD' wno '� `\ 21 REMOVE EXISTING CURB OR CURB AND GUTTER. <br /> ^��� Cll'OF EVERER PROPERn' RAPED SIGNAL AH IGN \ <br /> GE=575.37 ,`.ti. -, \��.,;�. \ <br /> IE 12"HOPE S=571.42 = D'K / NO TRESPASSING -:US STOP' <br /> IE 12"HOPE NE-5T.40 0, UNAUTHORIZED VEHICIFS IMP G \\ ® REMOVE EXISTING ASPHALT PAVEMENT OR SIDEWALK. <br /> 0 • GENERAL NOTES: <br /> I yi- ? G!1 \\ © RELOCATE EXISTING STREET LGHT LUMINAIRE. <br /> ` I qT m. ® \ 1. THE AREA WITHIN THE SITE BOUNDARY UNES <br /> y �. •� , t! t `� 0' 0 \\ cE=s72.43 00 TYPE I WILL BE CLEARED k GRUBBED INCLUDING THE 10' Q REMOVE EXISTING TREE(S). <br /> / _ _ j _ `_ ♦ \ IE 12'cDNc Nw=5sa63 EASEMENT SOUTH OF THE SOUTH PROPERTY LINE <br /> k-- � ,� _ _ \ IE 12°CONC 5E=568.63 AND ON THE PUD SUBSTATION PROPERTY. © PROTECT EXISTING PUD ELECTRICAL nT51tM5 AND <br /> i i L 1 11 .. - 'ST3_ �/'- `V POWER POLE. <br /> • LEGEND: <br /> S" i r \ ©6 EXISTING PUD DUCT BANK TO REMAIN. PROTECT <br /> P 1 0--'.. o-- ,'0* <br /> ; �� \ DURING CONSTRUCTION. <br /> � S� <br /> ��,a� PAVEMENT REMOVAL <br /> _ / `�` I rr a ,4��17 ��` `��' ,..�`` O�\ \\ INCLUDING SIDEWALKS <br /> \/(\ ,�-- - -;� `�` \ ® ADJUST EXISTING J-BOX/HANDHOLE TO GRADE. <br /> • y cr+^ I ---r.5„ ---=r rr ,r/ , !••,, e \ `1`� ` - \ \\\ SLOPE PROTECTION MULCH ® REMOVE EXISTING SIGN. <br /> .! / It I I ( • ,j-: -1-,-----.- '�. :`\ \--- \ ® NOT USED. <br /> 1_i ' QI ,� �, ` 0 \ \ \\\ m INLET PROTECTION O PROTECT EXISTING PEDESTRIAN PUSHBUTTON <br /> ©� - r / Ifaa 1 i ♦� �� -39tIH V 1M SILT FENCE ASSEMBLY. <br /> m o / �` 1 �, 1, ` \`I I r s• ♦\ f�� ``' �� Cc,7rta!UD=s7z.71 \\ EXISTING FEATURE TO BE REMOVED 31 PROTECT EXISTING LUMINAIRE. <br /> ` I �I m� i i �� i Ate' N• r `.,•� te © � V -� - - - INTERCEPTOR SWALE <br /> III -GORPO•' E&CONPINu\ I I I I I �, s Ns C � \ © PROTECT EXISTING POWER STRUCTURES. <br /> E)UCATIO GENTS" ; I ' I ' • <br /> I, �`` a ) �I '� rr ,•e `,�;• • \ • \ \ ® ROCK CHECKDAM <br /> in ® i 1 i 11 1 ICI \ �'I �� 11 i' %' ,•4. i� \\ �` `\ O SG1 SSEE IG4� PLANS FOR SIGNAL REMOVAL DWG <br /> `' I 1 1 " I 'I 1, r PUD SIGN @ '�` 1,S \ �`` ` !y __ \\ O NOT USED. <br /> b 10 1` '1 , , ' ( *HELP KEEP �/ f� ,rr 'O:` .:`V �\ �:\,.� \\ A <br /> �! •�1 I 1 ` m - � I FACILITY SAFE ?r • / `� S`\\\ \ \ I ® REMOVE EXISTING DRAINAGE STRUCTURE. <br /> V ! i I I I \ 7r \ \ CB 2528 TYPE <br /> c <br /> I O \ I i II 'I r ` \ .\ C�� \ \ EE 1271.50 <br /> CONC NW=566.20 O REMOVE EXISTING POWER STRUCTURE, BY OTHERS. <br /> I \ ` II `/ ` ; I I rr ry S. \ IE 12'LONG 5E=566.09 <br /> ',I, \ 1 L'� I 'I 'I i C!'� f, �`��\ '\ \ ® RELOCATE EXISTING J-BOX OR POWER STRUCTURE. <br /> �, Q ©. I 1 i r • i ♦ �' \ N. F, S \ \ MOVE CONDUIT AND REPLACE ALL WIRES TO NEW <br /> " W �'I � 1 1 I I i i IN I,` ��`�,` � V`AV�2-, 4 , \V LOCATION. <br /> .� - I I I • <br /> `� `.\ \ ® ADJUST EXISTING WATER STRUCTURE TO FINISHED <br /> ` 1 F 1 1 I I r f, ```\`�`, \� mA\ `�; -- '�j\ GRADE. BY OTHERS. <br /> r' a I I I r �i O ,• -`�' \ �'": ` \ O ADJUST EXISTING POWER STRUCTURE TO FINISHED <br /> i <br /> ° I t ��\` , - i i 1 i si ` ` `•�` A GRADE, BY OTHERS. <br /> , \\\\.. <br /> n. 1 1 1 iI I cRtr �i` `♦•�,��\:A � \\ 40 <br /> o ml D ! I 1 i 1 / ``�\` `O \`,`` \ PROTECT EXISTING SIGN. <br /> r rI ` '474 \ • 41 NOT USED. <br /> 1 I I ' I ' ,,;\ i i i i �� f, ``\ `C``\ I`, ; `\ \ \ <br /> t a I I m1' 1 I'I I II rr I ! ♦,i \ �``'\\�,`�\` 'Sa`� l \\ ® RELOCATE EXISTING WATER VALVE BEHIND PROPOSED <br /> `? I a i r i r i ,f ,' ```\ � `.V. a\ 1 \ SIDEWALK. <br /> r 1 co I I i , r�r r i / r \ y",-, > A <br /> r m I \ 1 i ( i r r\�i ., ♦, ```��\`\ ```\` �.\;\$r,- \ O RELOCATE EXISTING WATER METER BEHIND PROPOSED <br /> ` I i 1 r i Ir ♦� f, ``\`� ` \\\ �.\ - \ SIDEWALK AND EXTEND WATER SERVICE, BY OTHERS. <br /> 1 1E ` 1 r iI .� •,♦ ``�`�`�`� ``� �` 9 \ \\ ADJUST EXISTING GAS VALVE TO FINISHED GRADE, BY <br /> u 111111 Ls 1 , I. 1 II i i i I ' ♦! \\``\ \`\``\\ `� ''.by\\\ (fs \ O OTHERS. <br /> E ,, i i i I i i i I •, \` ``�`�`\\`` \ - I \\ RELOCATE EXISTING POWER STRUCTURE BEHIND <br /> 4 ' ',\ -\ i i i i i i ' I • \ �```�` \' \` 00 , \ O PROPOSED SIDEWALK, BY OTHERS. <br /> ai \I i , I II ♦ S 4 \ <br /> 1 I 1 1 , i i ,♦ \' � `` � \\. \ rr \\ REMOVE STRIPING. <br /> P I I I 1 , ` \ <br /> ry % I n I. I vh 1 i i i i i p �```\ ` `\ \ t'� , �� \ O PROTECT EXISTING TREE. <br /> IiiO '\ si \\ \ ' 1 O 1 • <br /> •� \ \ •t \. "F sios °NARBECK aka N° \ 47 <br /> "�`. ,,.j 1 I ' II �♦ • \ •, ` J \```\`v, \ .t 10' \\ \ 'ADOPT A 4 EY <br /> d �- 9' , ' -.. _. 1 DT Loll mw �` ` • P° A` <br /> MATC H LI N E SEE SHEET S P2 CALL 2 BUSINESS DAYS BEFORE YOU DIG All <br /> E 1 800 424 5555 V <br /> x UTILITIES UNDERGROUND LOCATION CENTER I <br /> U <br /> E COMMUNITY TRANSIT Drawing No. <br /> Pe rteet Drawn Date �.�F <br /> o��o 0 75%SUBMITTAL MMc 9/27/16 SP 1 <br /> DBefgned "°"� SEAWAY TRANSIT CENTER <br /> 425-252-770011-800615-9900 communitytran NOT FOR MN 9/27/16 1'-20' <br /> 2707 Colb Avenue,Suite 900 CONSTRUCTION Checked By Vert SITE PREPARATION & Sheet No. <br /> Pr - a BC 9/27/16 / <br /> No. Date Revision By APpr. Everett,Washington 98201 APPraved By Project Name. EROSION CONTROL PLAN r Total <br /> 20110155.023 <br />