My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
7505 SEAWAY BLVD SEPA 016 - 034 - SEAWAY TRANSIT CENTER Plans 2025-04-22
>
Address Records
>
SEAWAY BLVD
>
7505
>
SEPA 016 - 034 - SEAWAY TRANSIT CENTER
>
Plans
>
7505 SEAWAY BLVD SEPA 016 - 034 - SEAWAY TRANSIT CENTER Plans 2025-04-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2025 7:47:29 AM
Creation date
4/22/2025 7:36:36 AM
Metadata
Fields
Template:
Address Document
Street Name
SEAWAY BLVD
Street Number
7505
Tenant Name
SEPA 016 - 034 - SEAWAY TRANSIT CENTER
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
+ AGSREVIATIONS: SYMBOLS: —SECTION GRAPHICS LEGEND: GENERAL NOTES: <br /> AL ALUMINUM DESIGNATION <br /> AFF ABOVE FINISHED FLOOR _ / (LETTER) • 1 CONSTRUCTION SHALI.BE IN ACCORDANCE WITH THE 2012 INTERNATIONAL BU'LDING CODE A COPY OF THE APPROVED PLAN SHALL BE <br /> ARCH ARCHITECT.ARCHITECTURE • • • ON SITE WHENEVER CONSTRUCTION IS IN PROGRESS. <br /> AVE AVENUE SECTION (X� CIP CONCRETE(PLAN AND SECTION) <br /> BLD BUILDING SCALE: XXXXXX 2. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO INDEPENDENTLY VERIFY THE ACCURACY OF ALL BUILDING UTILITY LOCAL IONS <br /> E O S BOTTOM OF STRUCTURE �� • DRAWING NUMBER I/ PRECAST CONCRETE(SECTION) SHOWN AND TO FURTHER DISCOVER AND AVOID HARM TO ANY OTHER BUILDING UTILITIES NOT SHOWN HEREIN WHICH MAY BE <br /> BOT BOTTOM OF THE SHEET f LAFFECTED BY THE IMPLEMENTATION OF THIS PLAN. <br /> CAB CABINET WHERE THE <br /> CCTV CLOSED CIRCUIT TELEVISION SECTION IS SHOWN 3. THE CONTRACTOR SHALL TAKE APPROPRIATE STEPS REQUIRED TO PROTECT EXISTING BUILDING UTILITIES.EQUIPMENT OR BUILT-IN <br /> CES CUSTOMER EMERGENCY STATION MORTAR/GROUT FILL(SECTION) FURNISHINGS REMAINING IN THE WORK AREA DURING CONSTRUCTION. <br /> CIP CAST IN PLACE CIP/PRECAST CONCRETE(ELEVATION) <br /> CJ CONSTRUCTION JOINT 4. ALL DEMOLITION DEBRIS SHALL BE DISPOSED OF LEGALLY,OFF SITE. <br /> COMM COMMUNICATION(S) 4 <br /> CONC CONCRETE ) /'. STEEL 5. DO NOT SCALE THE DRAWINGS. <br /> CONST CONSTRUCTION L W,7. <br /> CONT CONTINUOUS 9 OVERALL DIMENSIONS INDICATED ARE TO FINISH SURFACES OR STRUCTURAL GRID-LINES AND OTHER DIMENSIONS ARE TO FACE OF <br /> D DEPTH ,0- CAST IN PLACE CONCRETE,OR FACE OF STRUCTURE UNLESS NOTED OTHERWISE. <br /> DET.DTL DETAIL /—SECTION •;;;;jj�, ALUMINUM <br /> DIA DIAMETER / DESIGNATION 10. DRAWING SCALES SHOWN ARE BASED ON A SHEET SIZE OF 34 X 22 INCHES.IF THE PRINTED SHEET SIZE IS 1/X 11 INCHES.THEN THE <br /> DIM DIMENSION / (LETTER) DRAWINGS HAVE BEEN REDUCED TO HALF THE SCALE INDICATED. <br /> t•..... <br /> DN D SECTION X �ri..®a RIGID INSULATION (PLAN AND SECTION) 11. THE DRAWINGS AND SPECIFICATIONS TOGETHER COMPRISE THE CONSTRUCTION DOCUMENTS. ANY DISCREPANCIES BETWEEN THEM <br /> DWG(S) DRAWING(S) SCALE: •EA EACH ‘....—../ ��� OR BETWEEN TWO OR MORE DRAWINGS SHALL BE REFERRED TO THE DESIGN QUALITY ASSURANCE MANAGER BEFORE ANY WORK <br /> EJ EXPANSION JOINT SECTION CUT ON THE AFFECTED S PERFORMED. <br /> ELEV ELEVATION SAME SHEET ONLY CONTINUOJS BLOCKING <br /> ELEC ELECTRICAL SECTION 12. SEE CIVIL DRAWINGS FOR LAYOUT AND DETAILS OF PAVEMENTS AND CURBS. <br /> EQ EQUAL DESIGNATION <br /> EXIST EXISTING (LETTER) 13. SEE DRAINAGE DRAWINGS FOR PLUMBING INFORMATION. <br /> EXT EXTERIOR `� _ r�� NON CONTINUOUS BLOCKING <br /> FE FIRE EXTINGUISHER ,� 14_ SEE STRUCTURAL DRAWINGS FOR STRUCTURAL ELEMENTS AND ATTACHMENT INFORMATION <br /> FEC FIRE EXTINGUISHER CABINET L`/� <br /> FT FOOT OR FEET XXXXXX'� ;" SEALANT AND BACKER ROD 15. SEE MECHANICAL DRAWINGS FOR MECHANICAL INFORMATION. <br /> F.O.C. FACE OF CONCRETE OR FACE OF CURB `� S—DRAWING NUMBER <br /> F.O.I.C. FURNISHED BY OWNER,INSTALLED BY CONTRACTOR OF THE SHEET 16. SEE ELECTRICAL DRAWINGS FOR TYPE AND LOCATION OF LIGHTING. <br /> F.O.S. FACE STEEL WHERE THE SECTION GLASS MAT SHEATHING <br /> GA GAUGEE ELEVATION DESIGNATION IS SHOWN 17 FOR COLORS AND FINISHES,SEE SPEC 09 06 00 COLORS AND FINISHES SCHEDULE. <br /> GALV GALVANIZED (NUMBER) , <br /> GL GLASS `./ _ + <br /> HDWR HARDWARE GLASS <br /> HR HOUR XXXXXX s <br /> HM HOLLOW METAL \-� �—DRAWING NUMBER <br /> HSS HIGH STRENGTH STEEL OF THE SHEET <br /> WHERE THE `0O000 <br /> HT HEIGHT 0 0 0 0 0 o TACTILE WARNING TILE <br /> ELEVATION IS SHOWN o 0 0 00 0 <br /> IBC INTERNATIONAL BUILDING CODE o 0 0 0 0 0 <br /> IN INCH <br /> J8 JUNCTION BOX <br /> JT JOINT ASPHALT PAVING <br /> MAX MAXIMUM DETAIL DESIGNATION <br /> MECH MECHANICAL (NUMBER) <br /> M MANUFACTURER �j� <br /> MININ MINIMUM DETAIL X % CANOPY(PLAN) <br /> MOW MAINTENANCE OF WAY SCALE: XXXXXX„. <br /> MTL METAL <br /> ` NA NOT APPLICABLE • DRAWING NUMBER <br /> OF THE SHEET ___ PERFORATED INFILL PANEL AT <br /> NICNOT IN CONTRACT <br /> NO NUMBERWHERE THE - = WINDSCREEN AND GUARD(ELEVATION) <br /> i NTS NOTT TOOSCALE <br /> DETAIL IS SHOWN <br /> e 0/ OVER <br /> OC ON CENTER FIRE RATED METAL WALL PANEL <br /> OPNG OPENING (PLAN AND SECTION) <br /> OPP OPPOSITE <br /> _ PC PRECAST <br /> PERF PERFORATED <br /> STRUCTURAL GRID <br /> PGL PROFILE GRADE LEVEL <br /> PLAT PLATFORM <br /> m PT PAINT ,—DETAIL DESIGNATION <br /> R RADIUS OR RISER (NUMBER) ® FALL ARREST SYSTEM <br /> g <br /> R- R VALUE <br /> RCP REFLECTED CEILING PLAN DETAIL (-5-0,/ <br /> F- REOD REQUIRED SCALE FE FIRE EXTINGUISHER AND BRACKET <br /> v RO ROUGH OPENING ' ' -DETAIL SHOWN <br /> t SECT SECTION ON THE SAME ® HOSE BIB <br /> SHT SHEET SHEET ONLY <br /> `, SIM SIMILAR r 1 <br /> SJ SCORE JOINT I I3 SCUPPER(FLOOR DRAIN) <br /> d SST STAINLESS STEEL I I DETAIL DESIGNATION <br /> s STRICT STRUCTURE OR STRUCTURAL L (NUMBER) , <br /> THK THICK.OR THICKNESS \ \ ILLUMINATE)EXIT SIGN <br /> i TOC TOP OF CURB \ ( __ , <br /> TOR TOP OF RAIL XXXXXX4011 <br /> TRD TREAD �/ CALL 2 BUSINESS DAYS BEFORE YOU DIGrl:S7 <br /> S TS TUBE STEEL <br /> DRAWING NUMBER DOOR NUMBER 800 424 5555 <br /> TYP TYPICAL OF THE SHEET <br /> UNO UNLESS NOTED OTHERWISE WHERE THE DETAIL DRAFT <br /> 8 VIF VERIFY NJ FIELD IS SHOWN L71 LOUVER NUMBER U1ILI(IES UNDERGROUND LOCATION CENTER <br /> EOil (DASH IF ON SAME <br /> WIO WITHOUT SHEET ONLY) <br /> f <br /> 1 <br /> COMMUNITY TRANSIT �`��° <br /> No <br /> .__. I IBI GROUP Dro.n Pit Dote v ct <br /> j __ 001 Soeontl Avenue-Sm1e 1400 - ! 60%SUBMITTAL D.>�.e r7/wna M f X <br /> I B I °eaII WA 08104 USA communf ty> i n.i' I` NOT FOR _le Wow, YEA SEAWAY TRANSIT CENTER <br /> H_— _ ___.___ _. .__.__. __. ___ __ _. Iel206521909t lex 200 521 9095 CONSTRUCTION cm M/07LrE c,.«� <br /> 1 1 Ibigrouv.com <br /> NO. Date Rec,on I .OP. "°°"°" 015a0 LEGEND AND ABBREVIATION t, <br />
The URL can be used to link to this page
Your browser does not support the video tag.