ENVELOPE COMPLIANCE SUMMARY <br /> 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all RI Administered by:©2022 NEEA,All rights reserved <br /> Project Title Bridge Point Everett 500-Building C-2018 WSEC For Building Department Use: Date• Apr 14,2022 <br /> 5900 36th Ave West <br /> Project Address Building C <br /> Project&Applicant Everett,WA 98203 <br /> Information Applicant Name John Llacuna <br /> Applicant Phone 425-646-1818 <br /> Applicant Email john.11acuna@SynThesisPLLC.com <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> General Occupancy All Commercial General Building Use Type Warehouse,Distribution Building Cond.Floor Area 122,543 <br /> Project Cond.Floor Area 0 <br /> Project Scope New Building Space Conditioning Categories Semi-heated Floors Above Grade 1 <br /> Compliance Method Compliance Method 1-General <br /> Envelope Project Description New semi-heated building shell to include wood sheathed roof with rigid insulation,concrete tilt walls,concrete slab-on-grade and insulated overhead doors. <br /> Envelope WWR/SRR <br /> Compliance Scope Space Conditioning Category Compliance Method per Category UA Calculation Adjustment Fenestration Alternates Compliance Verification <br /> Scope and <br /> Method New Building Semi-heated Component performance 5.91%/1.17% None selected No alternates selected COMPLIES <br /> Air Barrier Testing Air barrier testing included in project scope Air Barrier Comments <br /> Project Title Bridge Point Everett 500-Building C-2018 WSEC Date Apr 14,2022 <br /> Scope&Space Conditioning NEW BUILDING SEMI-HEATED Compliance Verification COMPLIES <br /> Window-to-wall Ratio 5.91% Skylight-to-roof-ratio 1 17% Vertical Fenestration Alternate No alternates selected <br /> Opaque Envelope Assemblies <br /> Insulation R-Values <br /> Walls-Semi-heated Space Location in Documents Assembly ID Assembly Location Cavity o Continuous Insulated Wall U-Factor Net Area(SF) <br /> (/o penetration) Furring <br /> Mass wall-Commercial A2.1,A2.2&A4.1 Tilt-up concrete panels Yes 0 U-0.104 54,023 <br /> Is this assembly exterior or interior?:Exterior <br /> Roof/Ceiling Location in Documents Assembly ID Assembly Location Cavity Continuous 2nd Layer U-Factor Net Area(SF) <br /> (%penetration) (MB Roof) <br /> Insulation entirely above deck A4.3 Wall Sections Insulation above deck Exterior R-30.00(<0.04%) U-0.032 119,271 <br /> U-Factor Source:WSEC Appendix A U-Factor Source Description:A102.2.6(1) <br /> Is this assembly exterior or interior?:Exterior <br /> Slab-on-grade Floors Location in Documents Assembly ID Assembly Location Slab Edge Under Slab F-Factor Perimeter <br /> Length(SF) <br /> Unheated slab A2.1 Uninsulated slab-on-grade At grade level R-00 R-00 F-0.73 1,989 <br /> Slab Insulation Method:Uninsulated slab F-Factor Source:WSEC Appendix A <br /> F-Factor Source Description:Table A106.1 <br /> Fenestration&Opaque Door Assemblies <br /> Insulation R-Values _ <br /> Opaque Doors Location in Documents Assembly ID Assembly Location Door Insulation U-Factor Rough <br /> Opening(SF) <br /> - <br /> Swinging A2.1&A3.1 3x7 ingress man doors Exterior U-0.360 380 <br /> What percentage of this opaque door is glazing?:50%or less U-Factor Source:WSEC Appendix A <br /> U-Factor Source Description:Table A107.1(1) Is this assembly exterior or interior?:Exterior <br /> Is this a public entrance door?:No <br />