0 <br /> i <br /> M SHUTLER <br /> '_■maja CONSULTING <br /> MN WilM ENGINEERS,INC. 12503 Bel-Red Road,Suite 100,Bellevue,WA 98005*(425)450-4075*FAX(425)450-4076 <br /> i <br /> 9-8-2022 <br /> Randy Brown <br /> SynThesis PLLC <br /> 12503 Bel-Red Road, Suite 100 <br /> Bellevue, WA 98005 1. <br /> RE: BP Everett 500 Building C <br /> Everett, WA <br /> Plan Check#B2204-051 <br /> Randy, <br /> Please find below my responses to the building department comments on the structural drawings for BP Everett <br /> 500 Building C. <br /> • Comment Number 1 : The lateral system is a combination of special reinforced concrete shear <br /> walls and special steel concentrically braced frames. This has been clarified in the general notes on <br /> sheet S-1.0. <br /> • Comment Number 2 : The brace sizes have been revised so they are now in agreement on both the <br /> foundation plan and frame elevation. The brace size is a W14x132. After the initial permit <br /> submission,the brace frame locations have been revised to better meet the owner's needs. As such <br /> the braces can now be found on grids F and K. <br /> F.: <br /> • Comment Number 3 : The load cases used in design of the system are for normal loading of the <br /> braced bay. Case one is when the loading is balanced between tension and compression. Case two <br /> is how we internally determine if the loading delivered to the system will cause the brace to <br /> buckle. Case three is how we determine the maximum compression load applied to the column <br /> using overstrength. Case four(sheet L-51 and L-52)is new and shows the maximum level of load <br /> transferrable to the system by overturning analysis. This maximum level of load transferrable to <br /> the system is a higher load than the overstrength load case,and was used to design the connections. <br /> • Comment Number 4 : The brace member has been revised to W14x132 in all details. This member <br /> is highly ductile and meets all requirements of AISC 341-16. <br /> • Comment Number 5 : The braced frame beams have been revised to W24x84,which meets highly <br /> ductile member requirements. The axial demand load for the frame beams is 316 kips and can be '' <br /> found on sheet L-66 of the structural calculations. <br /> • Comment Number 6 : Protected zones have been added to the elevation on sheet S-3.1. <br /> • Comment Number 7 : Braced frame connection calculations have now been completed and can be <br /> found on sheets L-66 through L-72 of the latest calculation package, <br /> • Comment Number 8 : Panel overturning has been checked on calculation sheets L-27 through L-39 <br /> of the revised structural calculation package. The required connections to stitch the panels together <br /> removes any individual panel overturning issues. These stitched connections are now shown on the <br /> panel elevations as type"G" connections. <br /> i.. <br />