My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
5900 36TH AVE W C BRIDGE POINT 2025-04-22
>
Address Records
>
36TH AVE W
>
5900
>
BRIDGE POINT
>
5900 36TH AVE W C BRIDGE POINT 2025-04-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/22/2025 10:10:52 AM
Creation date
4/22/2025 10:03:25 AM
Metadata
Fields
Template:
Address Document
Street Name
36TH AVE W
Street Number
5900
Unit
C
Tenant Name
BRIDGE POINT
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Seismic System Attachments <br /> TOLCO Fig. 4L- sway brace attachment (UL listed) <br /> Size Range: 1 (25mm)through 8" (200mm) IPS. 10' (250mm)and 12"(300mm) OPM c ®US <br /> not UL listed LISTED <br /> Material: Steel and stainless steel. Set Bolt& n • <br /> Function: For bracing pipe against sway and seismic disturbance. Hardware Included �� <br /> Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL)1" l <br /> ■ <br /> (25mm)through 8"(200mm) pipe. UL Listed for the following sprinkler type pipes: ii•E m j:i) <br /> Sch.40, Sch. 10, Bull Moose Eddy Flow,Wheatland Mega Flow, DIN 2448, KSD <br /> 3562, KSD 3507.Ask the factory for additional information as it may vary by product �I''� <br /> size. For FM Approval information refer to FM Approved page 35a. Included in I <br /> our Seismic Engineering Guidelines approved by the State of California Office ofiirA <br /> Statewide Health Planning and Development(OSHPD). For additional load,spacing D <br /> and placement information relating to OSHPD projects,please refer to our Seismic <br /> Engineering Guidelines, OPM-0052-13. <br /> Installation Instructions: Fig. 4L is the "braced pipe" attachment component Ell''---___±.7_---.-:\ <br /> of a longitudinal and lateral sway brace assembly. It is intended to be combined <br /> with the "bracing pipe" and TOLCO structural attachment component to forma complete bracing assembly. NFPA 13 guidelines should be followed. (For <br /> complete detailed instructions see instruction sheet IL309015EN). c <br /> To Install: Place the Fig. 4L over the pipe to be braced and tighten bolts.Then <br /> engage "bracing pipe" into jaw opening and tighten set bolt until head snaps off. ill II <br /> Jaw attachment can pivot for adjustment to proper brace angle. <br /> Finish: Plain, Electrogalvanized, Hot Dip Galvanized or Stainless Steel (only for <br /> 4" & 6" sizes). ' I <br /> Order By: Figure number, pipe size and finish. <br /> t <br /> OW. 1/111111r 44zie t ., <br /> -i1 to <br /> 41#1,, ' <br /> r. <br /> ill i, <br /> t co <br /> .� 4;rI 1 - tn' E <br /> -4 E w <br /> Lateral Longitudinal With Plain& With Hot Dip Galvanized& y Q <br /> Brace u Brace Electrogalvanized Finish Stainless Steel Finish to <br /> . <br /> UL Max.Rec.Load PLN&EG. t` <br /> Nom Pipe Size A(Max) C D Bolt Size Logitudinal Lateral Approx. & <br /> Part No. in. (mm) in. in. in. in. lbs. lbs. Wt./100 lbs. '' ' <br /> 4L-1 1 (25) 5 2 1'/a /r13 1000 1000 176 Eaton's B-Line series seismic bracing <br /> 4L-11/4 11/4 (32) 52/7 1 2'/ie 15/9 '/2-13 1000 1000 182 components are designed to be <br /> 4L-1'/2 1]; (40) 51/2 273 12/3 1/2-13 1000 1000 187 compatible only with other B-Line <br /> series bracing components,resulting <br /> 4L-2 2 (50) 62/7 22/3 2 /2-13 1600 1000 204 in a listed seismic bracing assembly. <br /> 4L-2'/z 2/, 67/s 3 2'/3 /2-13 2000 1000 217 Eaton B-Line Division warranty for <br /> 4L-65mm — (65) 67/s 3 273 '/2-13 700 1000 214 seismic bracing components will <br /> 4L-3 3 (80) 73/7 31/4 25/a 1/2-13 I 2000 1000 323 be the warranty provided in Eaton <br /> 4L-3'/2 3'/2 (90) 8 ' 312 27/a 1/2-13 2000 1000 343 B-Line Division standard terms and <br /> conditions of sale made available by <br /> 4L-4' 4 (100) 83/7 33/4 3'/a 1/2-13 2000'' 1000 253 Eaton,except that,in addition to the <br /> 4L-5 5 95/s 43/a 35/a 1/2-13 2000'' 1600`- 314 other exclusions from Eaton B-Line <br /> 4L-125mm — (125) 95/s 43/5 35/a it-13 1200 1600* 314 Division warranty,Eaton makes no <br /> 4L-6'''' 6 — 113/7 51/3 44/7 1/2-13 2000 1600* 540 warranty relating to B-Line series <br /> 4L-150mm — (150) 113/7 5'/3 44/ /z 13 1200 1600* 538 seismic bracing components that are <br /> 4L-8 8 — 133/5 62/5 52/3 1/2-13 2000 2100* 645 combined with products not provided <br /> o <br /> by Eaton. <br /> 4L-200mm — (200) 133/5 62/5 52/3 1/2-13 1400 2100' 643 <br /> 4L-10 ** 10 (254) 173/5 8'/4 71/4 '/z-13 NA NA 1349 <br /> 4L-12**** 12 (300) 193h 9/< 8/: /2-13 NA NA 1526 All dimensions in charts and <br /> on drawings are in inches. <br /> * Only UL listed as a lateral brace for use with a 1"(25mm)pipe as the brace member. Dimensions shown in • <br /> **Only UL listed as a longitudinal brace for use with a 1"(25mm)thru 1'/2"(40mm)pipe as the brace member. parentheses are in millimeters <br /> ***Fig 4L-4 and Fig 4L-6 are only sizes available in stainless steel 316. unless otherwise specified. <br /> ****FM approved not UL listed. <br /> Updated 4-7-21 <br /> B-Line series Seismic Bracing Products 35 Eaton <br />
The URL can be used to link to this page
Your browser does not support the video tag.