July 06, 2021 <br /> 130 Ft Monopole Tower Structural Analysis CCI BU No 815285 <br /> Project Number 85660.014.01, Order 565122, Revision 0 Page 3 <br /> 1) INTRODUCTION <br /> This tower is a 130 ft Monopole tower designed by Rohn. <br /> 2)ANALYSIS CRITERIA <br /> TIA-222 Revision: TIA-222-H <br /> Risk Category: II <br /> Wind Speed: 98 mph <br /> Exposure Category: C <br /> Topographic Factor: 1 <br /> Ice Thickness: 1 in <br /> Wind Speed with Ice: 30 mph <br /> Seismic Ss: 1.25 <br /> Seismic S1: 0.443 <br /> Service Wind Speed: 60 mph <br /> Table 1 -Proposed Equipment Configuration __ <br /> CenterNumber Number Feed <br /> Mounting Line Antenna <br /> of Antenna Model of Feed Line <br /> Level (ft) 'Elevation Antennas Manufacturer Lines Size (in) <br /> (ft) <br /> 102.0 3 Nokia AEQK <br /> 3 Alcatel Lucent B25 RRH4x30-4R <br /> 3 Alcatel Lucent E366A RRH4X45 <br /> 3 Alcatel Lucent RRH4x25-B30 6 1-5/8 <br /> 100.0 3 Commscope NNH4-65C-R6-HG 12 7/13 <br /> 99.0 _ <br /> 3 Nokia AHCA CCIV3 6 3/4 <br /> 3 Nokia AHLBBA_CCIV2 4 3/8 <br /> 3 Raycap DC6-48-60-18-8F <br /> 3 Kathrein 80010966 <br /> 99.0 <br /> 1 -- Platform Mount[LP 302-1] <br /> Table 2 -Other Considered Equipment <br /> Center Number Number Feed <br /> 'Mounting Line Antenna <br /> Level (ft) Elevation of Manufacturer Antenna Model of Feed Line <br /> (ft) Antennas Lines Size (in) <br /> -- <br /> 130.0 3 Samsung Telecom 2.5GHZ RRH-V3 <br /> 3 KMW ET-X-TW-73-15-63-18-62-18 <br /> 3 KMW ET-X-WM-18-65-8P <br /> 1 Samsung Telecom 2.5G 8T8R RADAR FILTER <br /> 129.0 <br /> 129.0 3 Samsung Telecom Optic Fiber Junction Cylinder 3 1-7/16 <br /> 3 Samsung Telecom Power Junction Cylinder <br /> 1 _-- T-Arm Mount[TA 602-3] <br /> 128.0 3 Samsung Telecom RRH-C2A w/EXT FILTER <br /> 3 Samsung Telecom RRH-P4 <br /> 3 Andrew E15S08P78 <br /> 86.0 87.0 3 Andrew TMBXX-6516-A2M 2 1-1/2 <br /> 12 7/13 <br /> 3 Nokia AHLOA <br /> tnxTower Report-version 8.1.1.0 <br />