Laserfiche WebLink
14 ' <br /> January 30, 2023 <br /> 12.5 ft Sector Frames Mount Replacement Analysis CCI BU No. 856390 <br /> Order 628726, Rev. 1 Page 3 <br /> 1) INTRODUCTION <br /> The mounting configuration consists of(3) proposed 12.5 ft Sector Frames designed by CommScope. <br /> 2)ANALYSIS CRITERIA <br /> Building Code: 2018 Washington State Building Code <br /> TIA-222 Revision: TIA-222-H <br /> Risk Category: II <br /> Ultimate Wind Speed: 110 mph <br /> Exposure Category: C <br /> Topographic Factor at Base: 1.0 <br /> Topographic Factor at Mount: 1.0 <br /> Ice Thickness: 1 in <br /> Wind Speed with Ice: 30 mph <br /> Seismic Ss: 1.374 <br /> Seismic Si: 0.488 <br /> Live Loading Wind Speed: 30 mph <br /> Man Live Load at Mount Pipes: 500 lb <br /> Table 1 —Proposed Equipment Configuration <br /> Elevation(ft) Antennas Mount I Modification <br /> Mount Centerline # Manufacturer Model Details <br /> 106 3 Nokia AEQK <br /> 3 Raycap DC6-48-60-18-8F <br /> 3 Alcatel Lucent B25 RRH4x30-4R <br /> 3 Alcatel Lucent B66A RRH4X45-4R (3)Proposed 12.5 ft <br /> 98 104 3 Alcatel Lucent RRH4X25-WCS-4R Sector Frames <br /> 3 Cellmax CMA-UBTULBULBHH/6517/17/21/21_CCIV2 designed by <br /> 3 CommScope NNH4-65C-R6 CommScope <br /> 3 Nokia AHLBBA_CCIV2 <br /> 3 Nokia AHCA_CCIV3 <br /> 102 3 Nokia AEQU <br /> ENG-FRM-10208, Rev. E <br />