Laserfiche WebLink
May 10, 2023 <br /> 100-ft Self-Supporting Tower Structural Analysis Report CCI BU No 856390 <br /> TEP Project Number 62974.851100 Order 628726, Revision 3 Page 3 <br /> 1) INTRODUCTION <br /> This tower is a 100-ft self-supporting tower designed by Andrew. The tower has been modified per reinforcement <br /> drawings prepared by Tower Engineering Professionals in August of 2016. <br /> 2) ANALYSIS CRITERIA <br /> TIA-222 Revision: TIA-222-H <br /> Risk Category: II <br /> Wind Speed: 110 mph <br /> Exposure Category: C <br /> Topographic Factor: 1.0 <br /> Ice Thickness: 1.0 in <br /> Wind Speed with Ice: 30 mph <br /> Seismic Ss: 1.374 <br /> Seismic S1: 0.488 <br /> Service Wind Speed: 60 mpn <br /> Table 1 - Proposed Equipment Configuration <br /> Center Feed <br /> Number Number <br /> Mounting Line Antenna 1 Line <br /> of Antenna Model of Feed <br /> Level (ft) Elevation Antennas Manufacturer Lines : Size <br /> (ft) (in) <br /> 106.0 3 Nokia AEQK <br /> 3 Comrnscope NNH4-65C-R6 <br /> Cellmax CMA- <br /> 3 <br /> Technologies UBTULBULBHH/6517/17/21/21_CCIV2 <br /> 3 Alcatel Lucent B66A RRH4X45-4R <br /> 104.0 3 Nokia AHCA_CCIV3 <br /> 3 Raycap DC6-48-60-18-8F <br /> 3 Alcatel Lucent RRH4x25-WCS-4R 12 7/8 <br /> 98.0 6 13/16 <br /> 3 Alcatel Lucent B25 RRH4�:30-4R <br /> 3 3/8 <br /> 3 Nokia AHLBBA_CCIV2 <br /> 102.0 3 Nokia AEQU <br /> 6 Generic 2.0 STD x 6' Radio Mount Pipes <br /> 9 Generic 2.5 STD x 12'Antenna Mount pipes <br /> 98.0 6 Generic 2.4 STD x 10' Corner Bracing Pipes <br /> 3 Generic 2.5 STD x 12.5' Face Horizontal Pipes <br /> 3 Comrnscope SFG22HDX12-4-H10 Sector Mount <br /> Table 2 -Other Considered Equipment <br /> Cenl:er Number Number Feed <br /> Mounting Line Antenna <br /> of Antenna Model of Feed Line <br /> Level (ft) Elevation Antennas Manufacturer Lines Size(in) <br /> (ft) <br /> 88.0 1 Decibel DB495-A <br /> 87.0 - - <br /> 87.0 1 Tower Mounts Pipe Mount[PM 601-1] <br /> tnxTower Report-version 8.1.1.0 <br />