Laserfiche WebLink
Page <br /> inxTower Job Paine Field (BU 856390) 10 of 27 <br /> Tower Engineering Project Date <br /> ProfessionalsTEP No. 62974.851100 08:36:09 05/10/23 <br /> 326 Tryon Road <br /> Raleigh,NC 27603 Client Designed by <br /> Phone:(919)661-6351 Crown Castle <br /> FAX:(919)661-6350 Anwar Ibrahim <br /> Tower Feed Line Description Feed Line K, Ka <br /> Section Record No. Segment Elev. No Ice Ice <br /> T5 14 FB-L98-002-XXX(3/80) 20.00-30.00 0.6000 0.6000 <br /> T5 16 Feed Line Ladder 20.00-30.00 0.6000 0.6000 <br /> T6 1 Climbing Ladder(Af) 10.00-20.00 0.6000 0.6000 <br /> T6 2 Safety Line 3/8 10.00-20.00 0.6000 0.6000 <br /> T6 4 LDF5-50A(7/8") 10.00-20.00 0.6000 0.6000 <br /> T6 7 Feed Line Ladder 10.00-20.00 0.6000 0.6000 <br /> T6 9 LDF5-50A(7/8") 10.00-20.00 0.6000 0.6000 <br /> T6 11 2"Flexible Conduit 10.00-20.00 0.6000 0.6000 <br /> T6 12 PWRT-608-S(13/16) 10.00-20.00 0.0000 0.0000 <br /> T6 14 FB-L98-002-XXX(3/8") 10.00-20.00 0.6000 0.6000 <br /> T6 16 Feed Line Ladder 10.00-20.00 0.6000 0.6000 <br /> T7 1 Climbing Ladder(Af) 0.00-10.00 0.6000 0.6000 <br /> T7 2 Safety Line 3/8 0.00-10.00 0.6000 0.6000 <br /> T7 4 LDF5-50A(7/8") 0.00-10.00 0.6000 0.6000 <br /> T7 7 Feed Line Ladder 0.00-10.00 0.6000_ 0.6000 <br /> T7 9 LDF5-50A(7/8") 0.00-10.00 0.6000 0.6000 <br /> T7 11 2"Flexible Conduit 0.00-10.00 0.6000 0.6000 <br /> T7 12 PWRT-608-S(13/16) 0.00-10.00 0.0000 0.0000 <br /> T7 14 FB-L98-002-XXX(3/8") 0.00-10.00 0.6000 0.6000 <br /> T7 16 Feed Line Ladder 0.00-10.00 0.6000 0.6000 <br /> User Defined Loads -Seismic <br /> Description Elevation Offset Azimuth E Ehr Eh: Eh <br /> From Angle <br /> Centroid <br /> ft ft K K K K <br /> CCISeismic Tower Section 1 90' 0' 0.0000 0.28 0.00 0.00 0.73 <br /> CCISeismic Tower Section 2 70' 0' 0.0000 0.37 0.00 0.00 0.76 <br /> CCISeismic Tower Section 3 50' 0' 0.0000 0.38 0.00 0.00 0.55 <br /> CCISeismic Tower Section 4 35' 0' 0.0000 0.23 0.00 0.00 0.24 <br /> CCISeismic Tower Section 5 25' 0' 0.0000 0.26 0.00 0.00 0.18 <br /> CCISeismic Tower Section 6 15' 0' 0.0000 0.30 0.00 0.00 0.13 <br /> CCISeismic Tower Section 7 5' 0' 0.0000 0.31 0.00 0.00 0.04 <br /> CCISeismic commscope_cfd 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> NNH4-65C-R6 <br /> CCISeismic commscope_cf'd 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> NNH4-65C-R6 <br /> CCISeismic commscope_cfd 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> NNH4-65C-R6 <br /> CCISeismic nokia cfd AEQK 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> CCISeismic nokia cfd AEQK 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> CCISeismic nokia cfd AEQK 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> CCISeismic nokia cfd AEQU 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> CCISeismic nokia cfd AEQU 98' 0'. 0.0000 0.02 0.00 0.00 0.06 <br /> CCISeismic nokia cfd AEQU 98' 0' 0.0000 0.02 0.00 0.00 0.06 <br /> CCISeismic cellmax 98' 0' 0.0000 0.03 0.00 0.00 0.09 <br /> technologies_cfd <br /> CMA-UBTULBULBHH/6517/1 <br /> 7/21/21_CCIV2 <br /> CCISeismic cellmax 98' 0' 0.0000 0.03 0.00 0.00 0.09 <br /> technologies_cfd <br /> CMA-UBTULBULBHH/6517/1 <br /> 7/21/21_CCIV2 <br /> CCISeismic cellmax 98' 0' 0.0000 0.03 0.00 0.00 0.09 <br />