Laserfiche WebLink
2018 WSEC Requirements for Commercial Buildings including Group R2, R3 & R4 over 3 stories & all R1 -- Administered by 02024 NEEA, All rights reserved <br />The following information is necessary to check a permit application for compliance with the lighting systems, motors and electrical system requirements in the <br />Washington State Energy Code, Commercial Provisions. <br />For questions about this report, contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />DES C405.4.2.2 <br />Space -By -Space <br />Demonstrate that total proposed wattage does E Sheets <br />Method <br />not exceed maximum allowed wattage; <br />identify locations of space types on plans, <br />including retail display areas and areas with <br />display, highlight and decorative lighting; <br />provide WSEC exterior lighting compliance <br />reports <br />ADDITIONAL EFFICIENCY CREDITS - REDUCED INTERIOR LIGHTING POWER DENSITY <br />NA C406.3.1 <br />Reduced interior <br />To comply with additional efficiency credit, <br />C406.3.2 <br />lighting power <br />demonstrate that total connected interior <br />density <br />lighting wattage is 10% or 20% less than the <br />total maximum allowed lighting wattage for <br />the area the reduced lighting power credit is <br />being applied to; indicate whether lighting <br />power allowance is based on the building area <br />method or space -by -space method; provide <br />WSEC exterior lighting compliance reports <br />C4063 <br />Reduced interior <br />For project with dv elllng unit,. to comply <br />lighting power <br />With additional efficiency credit Indicate in <br />density - d\\cllin_f <br />lighting fixture schedule that lamps within <br />unit lamp efficacy <br />installed interior luminaires have an efficacy <br />toting of at least 65 lumen, per watt; include <br />number of lamps and provide calculations that <br />demonstrate at least 959,c of lamps have this <br />:lfienr� ratine <br />EXTERIOR LIGHTING POWER & EFFICACY <br />C405.5.2 <br />Total connected <br />Itl"ludc all luminaires in exterior lighting <br />exterior lighting <br />fixture schedule: indicate fixture types. lamps. <br />I)OWer <br />ballasts. and manufacturer's watts per fixture <br />for the installed lamp <br />Identity exterior applications eligible for <br />lighting power exemption on plans and in <br />WSEC exterior lighting compliance reports: <br />indicate exception applied <br />C405.5.3(1) <br />Exterior lighting zone <br />indicate building exterior lighting zone as <br />specified by the AHJ <br />C=405.5. I <br />Exterior building <br />For building grounds fixtures rated at greater <br />,_r(wnd,, li Ming <br />than 50 watts. indicate rated lamp efficacy (in <br />lumens per watt) in fixture schedule <br />EXTERIOR LIGHTING POWER CALCULATION <br />C405.5.3 <br />Tradable allowances <br />Demonstrate that total proposed tradable <br />surface %kattage does not exceed maximum <br />allowed tradable surface wattage (including <br />base site allowance): identify locations of <br />tradable surfaces on plans; provide WSEC <br />exterior lighting compliance reports <br />Page 6110 <br />