Laserfiche WebLink
3/19/24, 9. , � —, <br />waenergycodes. corn/pri nt_p roject_su m rhtity_tt7rm.p h p? k=a WQ9Mj EyODM mZnZp PTE3J mN0aT00Ng==&print=1 <br />MECHANICAL COMPLIANCE SUMMARY <br />2018 WSEC Compliance Forms for Commercial Buildings including Group R2, R3 & R4 over 3 stories and all RI Administered by: (02024 NEEA, All rights reserved <br />Project & Applicant <br />Information <br />Project Title <br />Starbucks Broadway and loth GRAPHITE Reno (230809) - 2018 WSEC <br />For Building Department Use: I Date: Mar 19, 2024 <br />l <br />Project Address <br />1010 N Broadway <br />Everett, WA 98201 <br />Applicant Name <br />Rachel Abbott <br />Applicant Phone <br />206-224-3335 <br />Applicant Email <br />Rachel.Abbott@graphitedesigngroup.com <br />For questions about this report, <br />contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br />General Occupancy <br />All Commercial <br />General Building Use Type <br />Retail, General Sales <br />Building Cond. Floor Area <br />1,973 <br />General Project Types <br />Alteration <br />New Building <br />or Addition <br />Mechanical Scope <br />Alteration <br />Mechanical Scope <br />Single Zone Systems &Equipment <br />Project Cond. Floor Area <br />1,973 <br />Floors Above Grade <br />I <br />Compliance Method <br />General Prescriptive <br />Mechanical Project <br />Description <br />Economizer <br />DOAS Ventilation <br />Higher Equipment <br />Equipment Efficiency <br />Mechanical <br />Project Type <br />Mechanical Scope <br />Exception(s) <br />provided? <br />Efficient Option Applied? <br />y p pp <br />Compliance <br />Compliance <br />Applied? <br />Verification <br />Scope and Method <br />Alteration <br />Single Zone Systems & <br />Yes <br />No <br />NA <br />COMPLIES <br />Equipment <br />Additional Efficiency <br />Credits Included <br />(AEC) <br />Does building include <br />occupancy <br />No <br />Does project include DOAS equipment? <br />No <br />classifications <br />requiring DOHS? <br />Based on project scope <br />do TSPR requirements <br />No <br />Do all systems comply with Appendix D standard reference design or qualify for an exception to TSPR? <br />No <br />apply? <br />Scope & Space Conditioning ALTERATION - SINGLE ZONE SYSTEMS & EQUIPMENT Compliance Verification COMPLIES <br />Single Zone Air Systems Category - Heat pump, unitary, thru-wall, SDHV <br />Air Systems Summary Information <br />System/Equip ID <br />Quantity <br />of Items <br />Supply Airflow <br />Control <br />Ventilation Standard <br />Ventilation CFM <br />(Total if Multiple Items) <br />Ventilation <br />Air Source <br />Paired with DOAS <br />Ventilation energy recovery <br />Energy Recovery <br />Efficiency (%) <br />ASHP-I/AHU-11 <br />Constant volume <br />IMC Ventilation <br />1 1,600 <br />Integral <br />Not provided, not required <br />Air Systems & Equipment - Cooling <br />System/ <br />Cooling Capacity <br />AEC Efficiency <br />Econo Exception <br />Combined Efficiency <br />Proposed Cooling <br />I CE <br />I Proposed Part <br />I PL <br />Efficiency Compliance <br />Equip ID <br />Cooling System/Equip Type <br />I <br />Specific Type <br />per item (Btu/h) <br />Multiplier <br />Multiplier (FL & PL) <br />Multiplier (AEC & Econo) <br />Efficiency <br />Units <br />I Load Efficiency <br />Units <br />Verification <br />ASHP-1/AHU-1 <br />I Heat pump, air cooled <br />Split system <br />48,800 <br />1 <br />0 <br />1 <br />1 15.1 <br />SEER <br />I <br />I IEER <br />COMPLIES <br />Air Systems & Equipment - Heating <br />System <br />/Equip ID <br />System/Equip Type <br />I He <br />Specific Type <br />Heat Pump Heating Capacity (BhA) <br />Cooling Capacity (Btu/h) <br />AEC Efficiency <br />Multiplier <br />Proposed Heat Pump <br />Heating Efficiency <br />HPH <br />Units <br />Proposed Low OSA <br />Temp Efficiency <br />I LTH <br />JUnitsl <br />I Efficiency Compliance <br />Verification <br />ASHP-1/AHU-1 <br />I Heat pump, air cooled, heating <br />Split system <br />44,000 <br />48,800 <br />1 <br />9.0 <br />HSPF <br />COP <br />COMPLIES <br />Air Systems & Equipment Details <br />System/Equip ID I Area(s) Served Location In Project Documents - Plan/Detail # <br />https://waenergycodes.com/print project_summary_form.php?k=aWQ9MjEyODMmZnZpPTE3JmNOaT00Ng==&print=1 1 /2 <br />