My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1010 N BROADWAY STARBUCKS 2025-07-30
>
Address Records
>
N BROADWAY
>
1010
>
STARBUCKS
>
1010 N BROADWAY STARBUCKS 2025-07-30
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2025 4:16:23 PM
Creation date
4/23/2025 1:25:31 PM
Metadata
Fields
Template:
Address Document
Street Name
N BROADWAY
Street Number
1010
Tenant Name
STARBUCKS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
147
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL WOOD OBSERVATION REPORT <br />Report Number: <br />M7241374.0001 <br />Service Date: <br />08/12/24 <br />Report Date: <br />08/12/24 <br />Task: <br />Inspection Services <br />Client <br />Wilcox Construction <br />Attn: Liz Van Wieringen <br />234 5th Ave S <br />Edmonds, WA 98020-3425 <br />Permit No: B2311-026 <br />General Information <br />Project <br />■ Terracon <br />20225 Cedar Valley Rd Ste 110 <br />Lynnwood, WA 98036-6365 <br />425-742-9360 <br />Starbucks Store #22817 Broadway & 10th <br />1010 N Broadway <br />Everett, WA 98201 <br />Project Number: M7241374 <br />Garrett Combs with Wilcox requested Terracon to be at the above referenced project site for: framing observation. Observed work was being <br />performed by Wilcox. The results of observation(s) for today were reported to Garrett with Wilcox. <br />The construction documents referenced for this observation include: Structural plans dated 3/19/2024. <br />Framing Observation <br />Terracon observed wood framing detailed below for the following items (as applicable): exposure rating, panel grade, size, thickness, spacing, <br />connector manufacturer and configuration. <br />Element Type Floor/Location <br />Referenced <br />Document(s) <br />Blocking, Clips (1) Floor: Underside of the <br />Detail 6 on S201 <br />roof, SE corner <br />Blocking, Clips (2) Floor: Roof, Roof <br />Detail 8 on S201 <br />for the ASHP-1 <br />connection to <br />the existing <br />structure on the <br />roof <br />Status Comments <br />Complies This is for the 4x wood sub framing at the <br />open web truss <br />Complies Lag bolt lengths were increased to 10 " to <br />obtain the proper embedment <br />Compliance Statement <br />Based on our observations, structural wood construction at the above -referenced locations appeared to be completed in general accordance with <br />the project plans and specifications. <br />Services: Special Inspections / Materials Testing <br />Terracon Rep.: Michael Mattox <br />Reported To: Garrett with Wilcox <br />Contractor: Wilcox Construction <br />Report Distribution: <br />(1) Wilcox Construction, Liz Van (1) Terracon Consultants, Inc., Belinda <br />Wieringen Rix -Jones <br />(1) Terracon Consultants, Inc., Myndi Reviewed By: TLAA�D <br />ur�fr <br />Myndi Kr t <br />Project Manager <br />The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above <br />and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at <br />the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. <br />DM028, 04-29-22 Rev.1 Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.