Laserfiche WebLink
Calculation: Design Summary {1-1) <br />Code <br />Building Code: 2018 International Building Code <br />Local Building Code: - <br />Supplemental Code: 2016 ASCE 7 <br />Risk Category: II Standard -Occupancy Building <br />Seismic Design Parameters: <br />Ss: 1.385 SDs: 1.108 SMs: 1.662 Fe: 1.20 Ie: 1.00 <br />Si: 0.492 SDI: - SMi: - Fv: - <br />Note: 1 sec period seismic parameters require additional analysis per ASCE 7 Sect. 11.4.8 <br />Site Class: D (Default) <br />Seismic Design Category: D <br />Structural Height'hn': 37.0 R <br />Deadload Breakdown <br />Strut Grid Self Wt: <br />Strut B22E3 @ 10'-0" o.c. <br />Strut B22A @ 10'-0" o.c. <br />Electrical fixtures & conduits: <br />Misc steel: <br />Total dead load: <br />Existine Roof Deadload estimation: <br />Roofing: <br />3" 18ga metal deck (assumed): <br />MEP: <br />T-51 truss @ 10'-0" o.c.: <br />Misc: <br />Total: <br />ReidMiddleton <br />0.6 psf <br />0.4 psf <br />7.0 psf <br />1.5 psf <br />9.5 psf <br />3.0 psf <br />2.2 psf <br />2.0 psf <br />6.3 psf <br />1.0 psf <br />14.5 psf <br />728 134th St. SW, Ste 200, Everett, WA 98204 1 (425) 741-3800 <br />Project: Boeing Bldg 40-56 Pg. No: A- I <br />Address: 3003 W Casino Rd, Everett, WA 98204 Date: 2/6/2024 <br />Client: Sazan Group Job No.: 262024.011 <br />Pape 1 of 11 <br />