Laserfiche WebLink
• <br /> 2015 Washington State Ener• ode Compliance Forms for Commercial,R2 and R3 over- ones and all R1 -Page 5 of 7 <br /> Mechanical Permit Plans C,�cklist MECH-CHK <br /> 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2&R3 over 3 stories and all R1 Revised January 2017 <br /> Project Title: Concentra Everett Date 1/1/2015 <br /> The following information is necessary to check a permit application for compliance with the mechanical systems and equipment requirements of the <br /> Washington State Energy Code,Commercial Provisions <br /> Applicable Code Section Code Provision Information Required-Must be in permit documents Location in Building Department <br /> (yes,no,na) Documents Notes <br /> For buildings with food service,meat or deli departments that have z 500,000 Btu/h of remote <br /> refrigeration capacity for coolers/freezers,indicate condenser ER and use of captured energy <br /> (service water heating,space heating,or dehumidification reheating) <br /> C403 5 3 Energy recovery- N/A <br /> cooler/freezer condensers For buildings with z 40,000 sf conditioned floor area and with>_1,000,000 Btu/h of remote <br /> refrigeration capacity for coolers/freezers,indicate condenser ER and use of captured energy <br /> for service water heating and also for space heating,or dehumidification reheating <br /> N/A <br /> For buildings with 24-hour operation and with>1,500,000 Btu/h of heat rejection capacity and <br /> C403 5 4 Energy recovery- design service hot water load>250,000 Btu/h,indicate condenser ER to pre-heat service <br /> condenser systems water,or exception taken Provide calculations showing the amount of recovered heat that is <br /> utilized(60%of peak heat rejection load or pre-heat service water to 85°F) N/A <br /> Hydronic System Controls <br /> For hydronic system pump motors z 7 5 hp,indicate method of variable flow control(VSD or <br /> C403 2 13 'Variable flow control- equivalent method that requires z 30%design wattage at 50%design fluid flow),note <br /> C403 4 2 7 hydronic system pumps exception taken N/A <br /> Identity whether hydronic coils have DDC controls and associated manner of pump speed <br /> control(dfferential pressure,zone hydronic demand,etc) N/A <br /> For boilers that provide building heating,indicate controls that provide heating water <br /> temperature setback based on outdoor temperature N/A <br /> For heating and chilled water systems>_300,000 Btu/h,indicate systems are configured to <br /> C403 2 5 Hydronic system setback automatically reset supply water temperature based upon demand,or exception taken o <br /> C403 4.2 4 and part load controls If system pump motor hp z 3 hp,also indicate controls automatically reduce flow by>_50% N/A <br /> For chilled water systems(z 300,000 Btu/h,pump motor hp z 3 hp)that serve water-cooled <br /> unitary air conditioners,indicate VSD or staged pumps in chilled water system and heat <br /> rejection loop that reduce pump flow so that one control valve is nearly wide open,or to <br /> maintain a minimum differential pressure,or exception taken N/A <br /> C403 4 2 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A <br /> C403 4 6 Hot gas bypass limitation For cooling equipment with hot gas bypass,provide either multiple step unloading or <br /> continuous capacity modulation,indicate bypass capacity per Table C403 4 6 N/A <br /> C403 4 2 2 Two-pipe changeover Indicate changeover deadband(min 15°F),heating/cooling mode scheduling and <br /> systems changeover temperature range(limit 30°F) N/A <br /> C403 4 2 6 Chiller/boiler plant pump Indicate controls are configured to automatically reduce overall plant flow and shut-off flow <br /> isolation through individual chillers and boilers when not in use N/A <br /> For cooling towers with fan motors z 7 5 hp,indicate VSD and method to adjust fan speed <br /> C403 2 13 1 1 Heat rejection equipment- (adjusted based on leaving fluid temperature or condenser temperature/pressure of heat <br /> C403 4 3 1.1 variable flow control rejection device) N/A <br /> C403 4 3 1 2 For multiple-cell heat rejection equipment with VSD,indicate controls that ramp all fans in <br /> unison N/A <br /> C403 4 3 3 Heat rejection equipment- Indicate open-circuit cooling towers with multiple pumps or VSD control are designed so all <br /> cooling tower flow turndown cells can be run in parallel N/A <br /> C403 4 2 3 1 Water loop heat pump- Indicate capability of central equipment to provide minimum 20°F water supply temperature <br /> deadband deadband between heat rejection and heat addition modes,or exception taken N/A <br /> Water loop heat pump- Indicate type of cooling tower(open-or closed-circuit)in equipment schedule,indicate method <br /> C403 4 2 3 2 1 heat rejection equipment, used to limit system heat loss when heat rejection is not needed <br /> Zone 4 N/A <br /> Water loop heat pump- For open-or closed-circuit cooling towers,provide a heat exchanger that separates the cooling <br /> C403 4 2 3.2 2 heat rejection equipment, tower and heat pump loop <br /> Zone 5 N/A <br /> C403 4 2 3 3 Water loop heat pump- For hydronic heat pump systems with total system power>10 hp,indicate 2-way isolation <br /> isolation valves valves on each heat pump and variable flow system control N/A <br /> Dedicated Outdoor Air Systems(DOAS)-Optional through 6/30/16,Prescriptive 7/1/2016 <br /> For buildings with office,retail,education,library and fire station spaces,identify these spaces <br /> C403 6 Dedicated outdoor air on plans,indicate that ventilation air in each occupied space is provided via a DOAS system, <br /> C403 6 3 systems or document compliance with C403 6 3 Impracticality,or exception taken(buildings complying <br /> with C402 4 1 4 or C406 6 may not utilize exceptions) N/A <br /> Energy recovery ventilation For all DOAS systems,indicate exhaust air ER method,or exception taken with supporting <br /> C403 6 1 with DOAS calculations Indicate ER rated effectiveness that increases OSA enthalpy by>_50%based on <br /> delta between OSA and return air enthalpies at design conditions N/A <br /> Indicate equipment associated with the delivery of zone level heating and cooling(fans, <br /> Heating/cooling system hydronic pumps,primary air dampers,etc)are configured to shut off,and central equipment is <br /> C403 6 2 controls with DOAS configured to turn down,when there is no call for heating or cooling in the zone they serve N/A <br /> If applying Exception to heating/cooling fans used for air mixing in the space during deadband <br /> periods,include fan watts per cfm in equipment schedule N/A <br />