Laserfiche WebLink
L; V t E 1N 1498 Plans <br /> s .� �'F Structural Calculations <br /> E k t, By Jon Conner, P.E., S.E. <br /> Lakeview Structural Engineering <br /> Prepared for A&P Holdings, LLC <br /> Design Criteria: <br /> 4326 Crescent Ave, Everett <br /> Soil Loads: <br /> Active lateral earth pressure: 35 pcf <br /> Passive lateral earth pressure: 250 pcf <br /> Dead Loads: <br /> Soil: 120 pcf <br /> Concrete: 150 pcf. <br /> Design Codes and References: <br /> 2018 IBC, IRC for load calculations and general design criteria <br /> ASCE 7-16 for load calculations and general design criteria <br /> Concrete: ACI 318— 14 <br /> Timber: ANSI/AF&PA NDS-2018 for Wood Construction <br /> \\ 2 0 U 5 E In <br /> MAY 3 0 2024 Li <br /> vSHALL c <br /> wog WASFjj� Q4/ CITY ®F EVERETT <br /> T <br /> '. A� �, '' Permit Services <br /> —i0°1 <br /> 4,6 44672 ww W <br /> 0It eT�RALE C,. �4� <br /> 'SSjONAL V)G <br /> 5/17/2023 <br /> RCC EO E <br /> MAR 1 4 2024 <br /> CITY OF EVERETT <br /> Permit Services <br /> S <br />