Laserfiche WebLink
V3 SUPERCHARGER DATASHEET T - 5 L n <br /> R4.2 SEP 2020 CHARGING INFRASTRUCTURE DEPLOYMENT <br /> CABINETV3 SUPERCHARGER <br /> _ Input[VAC] 480 440 415 400 380 <br /> _ Peak AC Input Power Power[kVA] 387 354 334 322 306 <br /> _ AC Input Voltage 380 VAc-480 VAC(-5%, +10%),4-wire 3AC+N <br /> AC INPUT _ AC Input Current 465 AAc Max. <br /> Frequency 50 Hz/60 Hz <br /> Power Factor >_0.99 <br /> Current THD 2.376% <br /> Voltage THD 1.135% <br /> L1, L2, L3, N: 150—400mm2, 250MCM—750MCM <br /> AC Conductor Sizes INPUT PE:#14 AWG-2/0 <br /> _ Conductor Material Type L1, L2, L3, N: Cu,Al PE: Cu <br /> Mfr.Termination Temp Rating 90' C <br /> Input[VAC] 480 440 415 400 380 <br /> SHARED DC BUS Max Rated DC Bus Power Power[kW] 580 580 580 580 580 <br /> ELECTRICAL Max Rated DC Bus Current Current[ADC] 640 640 640 640 640 <br /> DC Bus Voltage Range 880-970 VDc <br /> V+, V-(2x/pole): 150—300mm2, 250MCM—600MCM <br /> Conductor Sizes Mid: 2.5—35mm2, 14 AWG—1 AWG <br /> SHARED DC BUS PE:#14 AWG-2/0 <br /> Conductor Material Type V+, V-, Mid: Cu,Al PE: Cu <br /> Conductor Voltage Rating 1000V <br /> Mfr.Termination Temp Rating 90' C <br /> Max. Rated Post Power 250 kW <br /> DC POST <br /> Post Rated Voltage Range 0-500 VDC <br /> ELECTRICAL• Post Rated Current @Ta=35° C Tesla Handle: 350 ADC,CCS2&GB Handle:450 ADC <br /> Number of Charge Posts 1 -4 <br /> Max Voltage Drop 10 VDc <br /> V+, V-(2x/pole): 350MCM or 185mm2 AL(certified equipment wiring) <br /> Conductor Size PE:#14 AWG-2/0 <br /> D POST Conductor Material Type V+,V-:Al, Cu PE: Cu <br /> Conductor Voltage Rating 1000V <br /> Mfr.Termination Temp Rating 90°C <br /> Efficiency 96% <br /> AC Input side: Class 1 DC Output side: Isolated DC Output <br /> • • Over Voltage/Current/Temperature, Surge Protection, Isolation Monitoring <br /> Short-Circuit Protection External Electronic Trip Circuit Breaker <br /> Short Circuit Current Rating 85 kA RMS symmetrical <br /> Operating Temperature -30°C to 50°C, -22°F to 122°F <br /> ENVIRONMENTALIngress Protection IP66(Cabinet), IP2X(Cooling) <br /> Ventilation Requirements Ventilation Not Required <br /> • Typical noise at 1 m 35 dB(A) <br /> UL 2202, CSA C22.2#107.1, FCC, ICES-003-13, IEC 61851-1, EN 61000-6-2 <br /> EN 55011, GB/T 18487.1, GB/T 27930, NB/T 33008.1, NB/T 33001 <br /> • Max. Distance to Charge Post 100 m, 340 ft. <br /> Supercharger Cabinet Weight 4 Post Cabinet: 1110 kg (2448 Ibs) 3 Post Cabinet:1 039kg (2291 Ibs) <br /> • Depth, Width, Height 1000, 1250, 2200 mm; 39 12/32,49 7/8, 86 20/32 in. <br /> • Per-anchor min. Shear Strength 4 kN <br /> Per-anchor min.Tension Strength 11 kN <br /> @ 2020 Tesla, Inc. <br />