Laserfiche WebLink
V3 SUPERCHARGER DATASHEET T - 5 L n <br /> R4.2 SEP 2020 CHARGING INFRASTRUCTURE DEPLOYMENT <br /> V3 SUPERCHARGER CHARGE POST <br /> -• Max. Rated Post Power 250 kW <br /> INPUT/OUTPUTJW Post Rated Voltage Range 0-500 VDC <br /> ELECTRICAL r Post Rated Current @Ta=35° C Tesla Handle: 350 ADC,CCS2 &GB Handle:450 ADC <br /> Power Conductors V+,V-(2x/pole): 350MCM or 185mm2 AL(certified equipment wiring) <br /> DC INPUT PE Conductor PE: 25-50mm2, 3AWG—1/0 <br /> Conductor Material Type V+,V-:Al, Cu PE: Cu <br /> Conductor Voltage Rating 1000V <br /> Mfr.Termination Temp Rating 90' C <br /> 00931TOTMATIMM Over Current/Temperature, Uneven Current Split <br /> ENVIRONMENTAL Operating Temperature -40°C to 50°C, -40°F to 122°F <br /> Ingress Protection IP44 <br /> - UL 2202, CSA 22.2#107.1-16, FCC, ICES-003, EN 61000-6-2, EN 61000-6-4, IEC 61851-1, <br /> IEC 61851-23, GB/T 18487.1, GB/T 27930, GB/T 20234.1, GB/T 20234.3, GB/T 34658 <br /> • Max. Distance to Cabinet 100 m, 340 ft. <br /> Charge Post Weight 64 kg, 140 lbs. <br /> • Depth, Width, Height 250, 810, 1687 mm; 9 27/32, 31 7/8, 66 13/32 in. <br /> • Per-anchor min. Shear Strength 1 kN <br /> Per-anchor min.Tension Strength 11 kN <br /> @ 2020 Tesla, Inc. <br />